• Title/Summary/Keyword: Monitoring channel

Search Result 459, Processing Time 0.025 seconds

UAV based Wireless Ad hoc Network Performance Analysis (공중무인기 기반의 무선애드혹 네트워크 성능 분석)

  • Chun, Jeong-myong;Ha, Dong-hun;Park, Jae-seong;Yoon, Seok-hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.123-125
    • /
    • 2015
  • Wireless ad hoc network which is comprised of wireless nodes that have the limited communication range is utilized to monitoring disaster area, tracing object, and tactical system. But in the case of wireless node on the ground, a network performance decrease because wireless channel is affected from obstacle or the node deployment is restricted. In this paper, we consider wireless network based on UAV(Unmanned Aerial Vehicle) which has little spatial constraint and quickly deploy a position. We implement test-bed included ground nodes and UAV, and measure throughput and PDR(Packet Delivery Ratio) according to the usage of UAV. We show that network performance is improved by relaying data on UAV.

  • PDF

Development of Single Channel ECG Signal Based Biometrics System (단채널 심전도 기반 바이오인식 시스템 개발)

  • Gang, Gyeong-Woo;Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • In general, currently developed ECG(electrocardiogram) based biometrics approaches are not suitable for real market applications since they require high cost ECG monitoring device and their measurement methods showed poor usability. In this paper, we developed lead I signal based biometrics system using special purpose ECG measurement hardware. To guarantee signal quality for biometrics from various signal measurement environment in our ordinary life, several filters are applied. In addition, to enhance usability, only two skin on electrodes without reference point are used for measurement. Lead I signals of seventeen candidates are measured from developed hardware and features are extracted. Extracted features are applied to support vector machine (SVM) pattern classifier for biometrics, and the experimental results showed 98.59% of sensitivity (SN) and 97.21% of accuracy (ACC). Compare to conventional ECG biometrics approaches, proposed system showed enhanced usability with low-cost measurement hardware.

Development of Pre-Processing and Bias Correction Modules for AMSU-A Satellite Data in the KIAPS Observation Processing System (KIAPS 관측자료 처리시스템에서의 AMSU-A 위성자료 초기 전처리와 편향보정 모듈 개발)

  • Lee, Sihye;Kim, Ju-Hye;Kang, Jeon-Ho;Chun, Hyoung-Wook
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.453-470
    • /
    • 2013
  • As a part of the KIAPS Observation Processing System (KOPS), we have developed the modules of satellite radiance data pre-processing and quality control, which include observation operators to interpolate model state variables into radiances in observation space. AMSU-A (Advanced Microwave Sounding Unit-A) level-1d radiance data have been extracted using the BUFR (Binary Universal Form for the Representation of meteorological data) decoder and a first guess has been calculated with RTTOV (Radiative Transfer for TIROS Operational Vertical Sounder) version 10.2. For initial quality checks, the pixels contaminated by large amounts of cloud liquid water, heavy precipitation, and sea ice have been removed. Channels for assimilation, rejection, or monitoring have been respectively selected for different surface types since the errors from the skin temperature are caused by inaccurate surface emissivity. Correcting the bias caused by errors in the instruments and radiative transfer model is crucial in radiance data pre-processing. We have developed bias correction modules in two steps based on 30-day innovation statistics (observed radiance minus background; O-B). The scan bias correction has been calculated individually for each channel, satellite, and scan position. Then a multiple linear regression of the scan-bias-corrected innovations with several predictors has been employed to correct the airmass bias.

A Study on Cure Monitoring of Fast Cure Resin RTM Process Using Dielectrometry (유전기법을 이용한 속경화 수지 RTM 공정의 경화 모니터링에 대한 연구)

  • Park, Seul-Ki;Kim, Cheol-Hwan;Choi, Jin-Ho
    • Composites Research
    • /
    • v.30 no.3
    • /
    • pp.202-208
    • /
    • 2017
  • Resin transfer molding (RTM) is a mass production process that allows the fabrication of composites ranging in size from small to large. Recently, fast curing resins with a curing time of less than about 10 minutes have been used in the automotive and aerospace industries. The viscosity of resin is bound up with the degree of cure, and it can be changed rapidly in the fast-cure resin system during the mold filling process. Therefore, it is advantageous to experimentally measure and evaluate the degree of cure because it requires much effort to predict the flow characteristics and cure of the fast curing resin. DMA and dielectric technique are the typical methods to measure the degree of cure of composite materials. In this paper, the resin flow and degree of cure were measured through the multi-channel dielectric system. A total of 8 channels of dielectric sensors were used and resin flow and degree of cure were measured and compared with each other under various pressure conditions.

Development of Integrated TCU for Multimedia Communication Devices Control (멀티미디어 통신기기 제어를 위한 통합 TCU 개발)

  • Lim, Yangmi;Kang, Namhi
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.1-6
    • /
    • 2014
  • Companies almost don't use an integrated control system using expensive network system in multimedia like TV and DID, despite IP-Broadcasting and communication equipment have expanded rapidly. The proposed integrated TCU(terminal control unit) is a control device that supports TV power On/Off check and remote control, power control reservation function, TV channel change, a variety of interface supports of input/output AC power & Lan port, RS-232C and IR using existing IP network after there is installed the Wake-on -Lan in the set-top box. The TCU can control and monitor 24 hours unlike existing low-cost control system RF method. In existing control equipment markets without expandability and low price, the TCU development including 24 hours monitoring and automatic control functions is expected to secure a wide range of companies.

A Study on the Evaluation of Travel Agency using Social Big Data (소셜 빅 데이터를 이용한 여행사 평가에 관한 연구)

  • Kong, Hyo-Soon;Song, Eun-Jee;Kang, Min-Shik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.10
    • /
    • pp.2241-2246
    • /
    • 2015
  • Recently for efficient management, companies have collected and investigated information about customers' feedback by using a system that analyzes big data from social media. This paper proposes more accurate and efficient evaluation method of collecting and investigating customers' feedback using social big data for travel agency, which is representative company of hospitality industry. First, it designs service model and, as a test-bed, analyzes media channel, customer satisfaction, and brand-image etc. of big 5 travel agencies in Korea. In addition, we suggest an analysis result of evaluating preference with positive rate and negative rate by proposed evaluation method. It allows a travel agency to know which area should be improved corresponding to evaluation item; thus, suggested evaluation method is effective to manage customers even more efficiently.

Control of $Ca^{2+}$- Influx by $Ca^{2+}$/Calmodulin Dependent Protein Kinase II in the Activation of Mouse Eggs

  • Yoon, Sook-Young;Kang, Da-Won;Bae, In-Ha
    • Development and Reproduction
    • /
    • v.15 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • Change in intracellular $Ca^{2+}$-concentration ($[Ca^{2+}]_i$) is an essential event for egg activation and further development. $Ca^{2+}$ ion is originated from intracellular $Ca^{2+}$-store via inositol 1,4,5-triphosphate receptor and/or $Ca^{2+}$ influx via $Ca^{2+}$ channel. This study was performed to investigate whether changes in $Ca^{2+}$/calmodulin dependent protein kinase II (CaM KII) activity affect $Ca^{2+}$ influx during artificial egg activation with ethanol using $Ca^{2+}$ monitoring system and whole-cell patch clamp technique. Under $Ca^{2+}$ ion-omitted condition, $Ca^{2+}$-oscillation was stopped within 30 min post microinjection of porcine sperm factor, and ethanol-induced $Ca^{2+}$ increase was reduced. To investigate the role of CaM KII known as an integrator of $Ca^{2+}$- oscillation during mammalian egg fertilization, CaM KII activity was tested with a specific inhibitor KN-93. In the eggs treated with KN-93, ethanol failed to induce egg activation. In addition, KN-93 inhibited inward $Ca^{2+}$ current ($I_{Ca}$) in a time-dependent manner in whole-cell configuration. Immunostaining data showed that the voltage-dependent $Ca^{2+}$ channels were distributed along the plasma membrane of mouse egg and 2-cell embryo. From these results, we suggest that $Ca^{2+}$ influx during fertilization might be controlled by CaM KII activity.

Label-free Femtomolar Detection of Cancer Biomarker by Reduced Graphene Oxide Field-effect Transistor

  • Kim, Duck-Jin;Sohn, Il-Yung;Jung, Jin-Heak;Yoon, Ok-Ja;Lee, N.E.;Park, Joon-Shik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.549-549
    • /
    • 2012
  • Early detection of cancer biomarkers in the blood is of vital importance for reducing the mortality and morbidity in a number of cancers. From this point of view, immunosensors based on nanowire (NW) and carbon nanotube (CNT) field-effect transistors (FETs) that allow the ultra-sensitive, highly specific, and label-free electrical detection of biomarkers received much attention. Nevertheless 1D nano-FET biosensors showed high performance, several challenges remain to be resolved for the uncomplicated, reproducible, low-cost and high-throughput nanofabrication. Recently, two-dimensional (2D) graphene and reduced GO (RGO) nanosheets or films find widespread applications such as clean energy storage and conversion devices, optical detector, field-effect transistors, electromechanical resonators, and chemical & biological sensors. In particular, the graphene- and RGO-FETs devices are very promising for sensing applications because of advantages including large detection area, low noise level in solution, ease of fabrication, and the high sensitivity to ions and biomolecules comparable to 1D nano-FETs. Even though a limited number of biosensor applications including chemical vapor deposition (CVD) grown graphene film for DNA detection, single-layer graphene for protein detection and single-layer graphene or solution-processed RGO film for cell monitoring have been reported, development of facile fabrication methods and full understanding of sensing mechanism are still lacking. Furthermore, there have been no reports on demonstration of ultrasensitive electrical detection of a cancer biomarker using the graphene- or RGO-FET. Here we describe scalable and facile fabrication of reduced graphene oxide FET (RGO-FET) with the capability of label-free, ultrasensitive electrical detection of a cancer biomarker, prostate specific antigen/${\alpha}$ 1-antichymotrypsin (PSA-ACT) complex, in which the ultrathin RGO channel was formed by a uniform self-assembly of two-dimensional RGO nanosheets, and also we will discuss about the immunosensing mechanism.

  • PDF

A Programmable Fast, Low Power 8 Bit A/D Converter for Fiber-Optic Pressure Sensors Monitoring Engines (광섬유 엔진 모니터용 압력센서를 위한 프로그램 가능한 고속 저전력 8 비트 아날로그/디지탈 변환기)

  • Chai, Yong-Yoong
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.163-170
    • /
    • 1999
  • A programmable A/D converter for an embedded fiber-optic combustion pressure sensor has been designed with 8 N and P channel MOSFETs, respectively. A local field enhancement for reducing programming voltage during writing as well as erasing an EEPROM device is introduced. In order to observe linear programmability of the EEPROM device during programming mode, a cell is developed with a $1.2\;{\mu}m$ double poly CMOS fabrication process in MOSIS. It is observed that the high resolution, of say 10mVolt, is valid in the range 1.25volts to 2volts. The experimental result is used for simulating the programmable 8 bit A/D converter with Hspice. The A/D converter is demonstrated to consume low power, $37\;{\mu}W$ by utilizing a programming operation. In addition, the converter is attained at the conversion frequency of 333 MHz.

  • PDF

50-GHz AWG Interrogation of a Multiple-FBG Temperature Sensor (50-GHz AWG를 이용한 다중 광섬유격자 브래그 파장 계측)

  • Moon, HyungMyung;Kwak, SeungChan;Kim, JinBong;Yim, Ju-Wan;Park, Dong-Young;Im, Kiegon
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.226-229
    • /
    • 2019
  • We investigated an interrogation system for fiber Bragg gratings by using a 50-GHz 96-channel array waveguide grating. Linearity of the sensitivity (the wavelength shift in response to the change in strain or temperature) is achieved for a Bragg grating of sufficiently wide bandwidth. The present wavelength-monitoring system could measure the change in Bragg wavelength with a resolution of 0.01 nm, at intervals of 10 seconds. When this interrogation system was used for a linear array of 12 acrylaterecoated fiber gratings, the wavelength sensitivity changed from 0.018 nm/℃ to 0.01 nm/℃ when the operating temperature changed from -25℃ to 85℃.