• 제목/요약/키워드: Monitoring and diagnostics

검색결과 163건 처리시간 0.037초

수도권 지역에서 환경대기 중 유해대기오염물질 (VOCs, Aldehydes, PAHs) 농도분포 특성 연구 (Study on the Distributions of VOCs, Aldehydes, PAHs Concentration in Seoul Metropolitan Area)

  • 한진석;이민도;임용재;이상욱;김영미;공부주;안준영;홍유덕
    • 한국대기환경학회지
    • /
    • 제22권5호
    • /
    • pp.574-589
    • /
    • 2006
  • Although concentrations of hazardous air pollutants(HAPs) are very low in the atmosphere, a growing attention has been paid on such compounds due to their high toxicity and bioaccumulation potentials into human body. In order to control and manage the amount of these materials in ambient air, it is necessary to construct monitoring system of them and to know the current concentration level of HAPs above all. In this work, a wide range of HAPs has been measured in metropolitan area to recognize the present state of HAPs in this area. The measured concentration of VOCs was higher in order of Jeonnongdong, Jeongdong, and Yangsuri. The regional difference of VOCs concentration was also highest in spring. Its total VOCs was ranged from $15.17{\sim}41.45$ ppb. Benzene $0.43{\sim}2.32$ ppb showed similar concentration level with the result of previous researches in Seoul. This value is a little higher than the average concentration 0.92 ppb for national ambient air quality standards in Japan. The concentration of aldehydes in this study was lower than those of other researches. Previous works in Seoul metropolitan area showed that the concentration of formaldehyde and acetaldehyde were higher than 5 ppb. The concentration of gaseous and particulate PAHs was high in order of winter, spring, and summer More than 90% of PAHs with low molecular weight such as 2-rings and 3-rings PAHs existed in gas phase. On the other hands, PAHs with high molecular weight more than 5-rings PAHs almost existed in particulate. In spring, the concentration of gaseous PAHs was 24.38 $ng/m^3$ in Jeongdong. Among the particulate PAHs, the concentrations of Naphthalene, Benzo(b)fluoranthene, and Benzo(g, h, i)perylene were higher than others. Especially, the concentration of Benzo(a)pyrene, a important carcinogenic pollutant, was highest in winter 0.5 $ng/m^3$ and ranged from 0.03 to 0.3 $ng/m^3$ in spring and summer, which is lower than the monitoring result in 90's. These components were mainly originated from the vehicle exhaust or heating equipment use.

The improvement of cut-off probe for measuring plasma density at hard conditions

  • 김대웅;유신재;김정형;성대진;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.202-202
    • /
    • 2011
  • Diagnostics of plasma density is a key factor for monitoring plasma processing. Various probes are invented to measure plasma density and cut-off probe is a one of the most promising diagnostics tool for measuring plasma density. However, at the low density or high pressure the cut-off probe cannot clearly resolve the cut-off peak. Several reasons make this problem: Cut-off likes peaks caused by cavity resonances and weaken transmission spectrum signal at high pressure. Recently, You et al., have researched mechanism of cut-off probe and we improve the cut-off reliability and sensitivity base on that research. Modified cut-off antenna is adapted and bias cut-off probe method is tried. These experiment results have good agreement with the previous study and show good measurement characteristics.

  • PDF

자동변속기 오일 온도센서 출력 이상 진단 로직 개발 (Development of A/T Oil Temperature Sensor Plausibility Diagnostic Logic)

  • 권준의;최영선;심장선
    • 한국자동차공학회논문집
    • /
    • 제13권6호
    • /
    • pp.99-104
    • /
    • 2005
  • The CARB in USA has demanded OBD functions that detect any deterioration of performance of OTS as well as a simple defect of OTS which can affect emission to meet the reinforced emission regulation. In this paper, OTS plausibility monitoring functions to meet the demand from CARB are discussed. The output from OTS is used for the diagnostics of the torque converter clutch stuck and the gear ratio synchronous error. It is possible to diagnose the abnormality of OTS function by considering the oil temperature characteristics which changes according to the driving status of vehicles. In result, the OBD regulations of the CARB can be satisfied obligating car manufacturer to detect any problems in OTS functions which can affect emissions.

배전반 시스템의 온라인 감시 및 진단 (On-line Monitoring and Diagnostics for Distribution Panel System)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.106-110
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

배전반 설비의 온라인 모니터링 및 진단의 동향 (Trend in Off-Line PD Monitoring with HVAC Testing)

  • 윤주효;홍창일;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

OBD-II 정보를 이용한 운전자 스트레스 모니터링 시스템 (Driving Stress Monitoring System Based on Information Provided by On-Board Diagnostics Version II)

  • 조상진;조영
    • 한국전자통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.29-38
    • /
    • 2023
  • 인간의 생체 신호 데이터가 인간의 상태를 가장 잘 설명할 수 있다 할지라도 실제 운전 중에 운전자의 생체 데이터를 얻어 운전자의 상태를 판단하는 일은 쉽지 않다. 본 논문에서는 이러한 한계를 극복하기 위한 방법 중 하나로 운전자의 주행 정보를 이용한 운전자 스트레스 모니터링 시스템을 제안한다. 운전자의 주행 정보는 OBD-II 스캐너를 통해 취득하고, 실제 운전자의 운전 스트레스 여부는 E4 밴드를 통해 취득한 EDA 데이터를 이용하여 판단한다. 스트레스 감지 모델은 MLP 신경망 모델을 사용하였으며 약 한 달 간의 운행 데이터를 이용하여 학습시켰다. 제안한 시스템을 평가하기 위하여 약 1시간의 운행 데이터를 사용하였고 약 92%의 정확도를 얻을 수 있었다.

Application of structural health monitoring in civil infrastructure

  • Feng, M.Q.
    • Smart Structures and Systems
    • /
    • 제5권4호
    • /
    • pp.469-482
    • /
    • 2009
  • The emerging sensor-based structural health monitoring (SHM) technology has a potential for cost-effective maintenance of aging civil infrastructure systems. The author proposes to integrate continuous and global monitoring using on-structure sensors with targeted local non-destructive evaluation (NDE). Significant technical challenges arise, however, from the lack of cost-effective sensors for monitoring spatially large structures, as well as reliable methods for interpreting sensor data into structural health conditions. This paper reviews recent efforts and advances made in addressing these challenges, with example sensor hardware and health monitoring software developed in the author's research center. The hardware includes a novel fiber optic accelerometer, a vision-based displacement sensor, a distributed strain sensor, and a microwave imaging NDE device. The health monitoring software includes a number of system identification methods such as the neural networks, extended Kalman filter, and nonlinear damping identificaiton based on structural dynamic response measurement. These methods have been experimentally validated through seismic shaking table tests of a realistic bridge model and tested in a number of instrumented bridges and buildings.

광온도센서를 이용한 분전반의 온라인 진단 및 감시 (On-Line Diagnostics and Monitoring of Distribution Panel Using IR-Sensor)

  • 윤주호;최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2110-2111
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

배전설비의 온라인 모니터링과 진단 기술 동향 (A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments)

  • 임완수;이태우;여운철;이성길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

A Design of Condition Monitoring System for Predictive Maintenance

  • Jeong, Hai-Sung;Kim, Heung H.;Sang K. Yun;Elsayed A. Elsayed
    • International Journal of Reliability and Applications
    • /
    • 제2권1호
    • /
    • pp.57-71
    • /
    • 2001
  • Global competition to increase production output and to improve quality is spurring manufacturing companies to use condition monitoring and fault diagnostic systems for predictive maintenance. As monitoring, testing, and measuring techniques develop, predictive control of components and complete systems have become more practical and affordable. In this article, we will consider the computer based data acquisition system for condition monitoring and the condition parameter analysis techniques for fault detection and diagnostics in the machinery and briefly discuss reliability prediction and the limit value determination in condition monitoring.

  • PDF