• Title/Summary/Keyword: Monitoring Stations Network

Search Result 115, Processing Time 0.033 seconds

Intrabed and Interbed Networks for Patient Monitoring (환자 모니터링을 위한 인트라베드 및 인터베드 통신망)

  • Park, Seung-Hun;Woo, Eung-Je;Kim, Kyung-Soo;Choi, Keun-Ho;Kim, Seung-Tae;Lee, Hee-Cheol;Seo, Jae-Joon;Kim, Hyung-Jin
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.285-289
    • /
    • 1997
  • In this paper, we describe the intrabed and interbed network in a developed patient monitoring system. Intrabed network handles data communication among the main unit of a bedside monitor and parameter modules plugged in it. Interbed network deals with a higher level data communication among many bedside monitors, central stations, DB servers, and clinical workstations. Analyzing the data communication requirements in each stage of the system, we designed the intrabed network based upon RS-485 and HDLC protocol with 1Mbps data rate. Interbed network is designed to utilize the industry standard 10Base-T Ethernet with TCP/IP and UDP protocol. We present the specifications and the performances of the developed data communication networks in the patient monitoring system.

  • PDF

Cavitation Condition Monitoring of Butterfly Valve Using Support Vector Machine (SVM을 이용한 버터플라이 밸브의 캐비테이션 상태감시)

  • 황원우;고명환;양보석
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.2
    • /
    • pp.119-127
    • /
    • 2004
  • Butterfly valves are popularly used in service in the industrial and water works pipeline systems with large diameter because of its lightweight, simple structure and the rapidity of its manipulation. Sometimes cavitation can occur. resulting in noise, vibration and rapid deterioration of the valve trim, and do not allow further operation. Thus, the monitoring of cavitation is of economic interest and is very importance in industry. This paper proposes a condition monitoring scheme using statistical feature evaluation and support vector machine (SVM) to detect the cavitation conditions of butterfly valve which used as a flow control valve at the pumping stations. The stationary features of vibration signals are extracted from statistical moments. The SVMs are trained, and then classify normal and cavitation conditions of control valves. The SVMs with the reorganized feature vectors can distinguish the class of the untrained and untested data. The classification validity of this method is examined by various signals that are acquired from butterfly valves in the pumping stations and compared the classification success rate with those of self-organizing feature map neural network.

Development of a remote monitoring system for gas detection at the subway station (지하철 역내 가스 검출 원격 모니터링 시스템 구현)

  • Park, Yong-Man;Kim, Hei-Sik;Kim, Gyu-Sik;Lee, Moon-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.439-441
    • /
    • 2007
  • The seoul metropolitan subway has installed 8 lines and about 500 stations to transport 5 million passengers everyday. The underground air pollution level in the subway stations is very severe status, which is very harmful to the commutators and its personals. Although subway roles as such a massive and huge transportation system, the subway doesn't adapt yet any real-time air monitoring system. They have only some hand-held type detector equipments for monitoring air pollution. Therefore subway passengers are exposed to the harmful air pollution environment. The most harmful environmental parameters among the air pollution are known as the dust and sound noise dB level in the subway station. Because the dust is consisted of very small particles, we can't see them easily in dark condition on the platform, but it is very harmful. The monitoring system for air pollution is developed using embedded system attached with 6 different environmental sensors. This system monitors air pollution of dust sound noise, gas, temperature, humidity, inflammable gas, toxic gas in the subway ?station. The sensor unit of the ARM-CPU board and sensor transmits real time environmental data to the main server using Zigbee wireless communication module and TCP/IP network. The main control server receives and displays the real-time environmental data, and it send alarms to the personals when high level value.

  • PDF

A Study on the Hierarchical Real-time Operation Control and Monitoring for an Flexible Manufacturing System (유연생산시스템의 계층구조적 실시간 운용제어 및 모니터링에 관한 연구)

  • Kim, Jong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.4
    • /
    • pp.36-43
    • /
    • 1992
  • This paper presents a hierarchical real-time operation control and monitoring scheme of the FMS/CIM center which has been implemented at the Automation and Systems Research Institute of Seoul National University. The hierarchical structure of the whole scheme consists of three lavers. The upper layer is in charge of on-line scheduling, computer network control, shop-floor monitoring and command generation for AGV dispatching, machining, assembly, inspection, set-up, etc. The middle layer has six modules, which are installed in the FMS host computer with the upper layer and run on the multi-tasking basis. Each module is connected to one of six cell controllers distributed in the FMS model plant and transfers operation command down to each cell controller through the Ethernet/TCP-IP local area network. The lower layer is comprised of six cell control software modules for machining cell, assembly cell, inspection cell, set-up stations. AS/RS and AGV. Each cell controller reports the status of the manufacturing facilites to the middle layer as well as ecxecuting the appropriate sequence control of the manufacturing processes.

  • PDF

An Assessment Study for the Urban Air Monitoring Network in Seoul (서울지역 도시대기측정망 평가 연구)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Ji Soo;Kim, Chan Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.504-509
    • /
    • 2014
  • Twenty-five stations of the urban monitoring network in Seoul were assessed with a focus on surveillance function of the exceedances of 8-hour ozone and 24-hour $PM_{10}$ standards. The two standards were selected because their attainment rates were particularly low. Two hierarchical cluster analyses were performed to group stations with similar atmospheric environments-one using daily highest 8-hour [$O_3+NO_2$], 8-hour $O_3$ concentrations plus corresponding 8-hour $NO_2$ concentrations considering the interconversion of $O_3$ and $NO_2$, and the other using 24-hour $PM_{10}$ concentrations. An index to measure higher concentration and exceedances of the standards was introduced. Within a cluster, sufficiently high score was assigned to the trends station or the station with higher index. Scores for $O_3+NO_2$ and $PM_{10}$ of a given station were added and ranked in the descending order to determine the relative importance.

Implementation of Communication Network Utilizing AIS Technology

  • Park, Soo-Hong;Lee, Jong-Nyen
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.370-375
    • /
    • 2008
  • Automatic Identification System (AIS) is recently introduced to the maritime navigation systems. It is aimed to increase safety of vessels at sea by exchanging information to coastal monitoring stations. This article presents a ship traffic monitoring system by using the AIS information communication system using MS Visual C++. Then, the mobile Internet AIS introduced here is considerably improving and extending AIS functionalities compared to VHF AIS. When each ship is connected to the Internet network through the developed AIS system with her own client ID, all of her AIS information is surely sent to a server at her own base station by processing the information via the Internet network.

A Commentary on Air Pollution Monitoring Programs in Korea

  • Ghim, Young-Sung;Kim, Jin-Young;Shim, Shang-Gyoo;Moon, Kill-Choo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.21-28
    • /
    • 2002
  • Air quality issues in Korea rapidly changed at the beginning of the 1990s from primary to secondary pollutants starting in Seoul, the capital of Korea. The present frame of national air pollution monitoring networks was established between the end of the 1980s and the beginning of the 1990s. Background monitoring was initiated in the middle of the 1990s in response to increasing public concern about the long-range transport of air pollutants. Apart from the national monitoring, both routine and intensive measurements of fine particles have been made for research purposes since the middle of the 1990s at several background sites. However, air pollution monitoring in urban areas for other purposes was relatively scarce as national monitoring has been concentrated in these areas. Although ozone pollution has become a significant issue in major metropolitan areas every summer, only a little information on ozone precursors is available. During the past few years, the number of national monitoring stations has greatly increased. The government has a plan to gradually expand monitoring items as well as stations. It is anticipated that highly detailed information on both photochemical reactants and products will be available within the next several years. More emphasis will be placed on toxic substances based on risk assessment in monitoring for both research and policy making.

Interbed Networks in la Patient Monitoring System (환자 모니터링 시스템에서의 통신 방식(II): 인터베드 통신망)

  • 박승훈;우응제;김경수;최근호;김승태
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.381-388
    • /
    • 1997
  • In this paper, we present the design and implementation of the interbed network communication protocol, which links patient monitors, central stations, DB servers, and clinical workstations together in a patient monitoring system. We describe the requirements to be met thor real-time patient monitoring, propose 2 services Patient Locator Service(PL:7) and Remote Patient Monitoring Service( RPMS). PLS provides the information about how many patients are currently being monitored and where they are located, while RPMS allows the doctors to monitor their patients'vital sign in real-time. The messages for the services, their formats and exchange scheme are also presented with a whole picture of how they are implemented. We adopted the object-oriented programming paradigm in all the analysis and design processes. In the experiment performed in a real clinical setting, the services turned out to meet all the requirements needed for real-time patient monitoring.

  • PDF

The Wireless Network Optimization of Power Amplification via User Volume in the Microcell Terrain

  • Guo, Shengnan;Jiang, Xueqin;Zhang, Kesheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2581-2594
    • /
    • 2018
  • The microcell terrain is the most common wireless network terrain in our life. In order to solve wireless network optimization of weak coverage in the microcell terrain, improve call quality and reduce the cost of the premise, power amplifiers in base stations should be adjusted according to user volume. In this paper, characteristics of microcell topography are obtained after analysis. According to the topography characteristics of different microcells, changes in the number of users at different times have been estimated, meanwhile, the number of scatter users are also obtained by monitoring the PCCPCH RSCP and other parameters. Then B-Spline interpolation method has been applied to scatter users to obtain the continuous relationship between the number of users and time. On this basis, power amplification can be chosen according to changes in the number of users. The methods adopted by this paper are also applied in the engineering practice, sampling and interpolation are used to obtain the number of users at all times, so that the power amplification can be adjusted by the number of users in a microcell. Such a method is able to optimize wireless network and achieve a goal of expanding the area of base stations, reduce call drop rate and increase capacity.