• 제목/요약/키워드: Monitoring Point

검색결과 1,353건 처리시간 0.032초

장기관측자료를 이용한 DOAS와 점측정 분석시스템의 바이어스 구조에 대한 평가 (Compatibility of DOAS and Conventional Point Monitoring System Through an Evaluation of Bias Structures Using Long-term Measurement Data in Seoul)

  • 김기현;김민영
    • 한국대기환경학회지
    • /
    • 제17권5호
    • /
    • pp.395-405
    • /
    • 2001
  • To make an assessment of the compatibility between DOAS and conventional point monitoring system (MCSAM-2: MS2), we investigated the concentrations of three criteria pollutants which include S $O_2$, N $O_2$, and $O_3$from a national monitoring station in Seoul during the periods of June 1999~August 2000. The average concentration values for the whole study period derived from hourly concentration data sets of those three species indicated that the mean differences between the two methods can be approximated as 18%. When the bias structure of two systems was evaluated through the computation of percent difference(PD) between the two such as ( $C_{DOAS}$- $C_{conventional}$ $C_{DOAS}$*100, differences between the two systems appeared to be quite systematic among different compounds. While the mode of bias peaked at 0~20% or 20~40% in terms of PD values, the cause of such positive bias mainly arised from generally enhanced concentration values of DOAS system. The structure of bias among different species was further assessed through linear regression analysis. Results of the analysis indicated that the dominant portions of differences observed from two monitoring systems can be accounted for by the systematic differences in their spanning and zeroing systems. S $O_2$(MS2)=0.6385 S $O_2$(DOAS)+2.0985($r^2$=0.7894) N $O_2$(MS2)=0.6548 N $O_2$(DOAS)+7.437($r^2$=0.7687) $O_3$(MS2)=1.0359 $O_3$(DOAS)-7.7885($r^2$=0.7944) The findings of slope values at around 0.64~0.65 from two species suggest that DOAS should respond more sensitively in upper bound concentration range. The offset values apart from zero indicate that more deliberate comparison needs to be made between these monitoring systems. However, based on the existence of strong correlations from at least 8,000 data points for each species of comparison, we were able to conclude that the compatibility of two monitoring systems is highly significant. With the improvement of calibration techniques for the DOAS system. its applicability for routine monitoring of airborne pollutant species is expected to be quite extendable.

  • PDF

종단 대 종단 프로토콜을 사용하는 웹 서버 환자감시장치 구현에 관한 연구 (A Study on the Implementation of Web Server Patient Monitoring System using Point to Point Protocol)

  • 최재석;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.463-467
    • /
    • 2000
  • 본 논문에서는 종단대 종단 프로토콜을 이용하는 웹 서버 환자감시장치를 구현하였다. 환자감시장치의 가격을 낮추기 위해서 심전도를 획득할 수 있는 아날로그 보드와 데이터를 처리, 전송할 수 있는 모듈만으로 구성하여 하드웨어의 복잡도를 줄였다. 아날로그 보드는 기존의 심전도획득보드를 사용하였다. 데이터 전송 모듈은 전화접속 네트워크 기능을 수행하기 위한 종단 대 종단 프로토콜, 인터넷을 통한 통신과 서버 동작을 하기 위한 TCP/IP, 웹브라우저를 통한 환자감시장치를 위해 HTTP 그리고 환자감시장치와 통신하기 위한 JAVA처리 프로그램이 하나의 칩에 구현이 되었다. 이러한 네트워크 구성은 가정에 있는 전화망을 사용할 수 있어 별도 망을 구성하지 않아도 되며 서버로 동작하므로 계속적으로 통신망을 열지 않더라도 사용자가 환자를 감시하고 싶을 때 감시가 가능하게 한다. 그리고 환자감시장치를 제어, 감시할 수 있는 프로그램은 접속과 함께 JAVA코드로 전송되어 웹브라우저에서 실행되므로 전화 접속이 가능한 컴퓨터라면 환자 감시를 가능하게 한다. 본 논문에서 제안한 환자감시장치는 저가의 가정용 환자감시장치 개발을 가능하게 하고 사용자의 환자를 감시하기 위한 위치나 시간의 제약을 덜게 할 것이다.

  • PDF

Implementations of Remote Sensing, GIS, and GPS for Water Resources and Water Quality Monitoring

  • Wu, Mu-Lin;Chen, Chiou-Hsiung;Liu, Shiu-Feng;Wey, Jiun-Sheng
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.1191-1193
    • /
    • 2003
  • Water quantity and quality monitoring at Taipei Watershed Management Bureau (WRATB) is not only a daily business but also a long term job. WRATB is responsible for providing high quality drinking water to about four millions population in Taipei. The quality of drinking water provided by WRATB is among one of the best in Taiwan. The total area is 717 square kilometers. The water resource pollution is usually divided into two categories, point source pollution and nonpoint source pollution. Garbage disposal is the most important component of the point source pollution, especially those by tourist during holidays and weekends. Pesticide pollution, fertilizer pollution, and natural pollution are the major contributions for nonpoint source pollution. The objective of this paper is to implement remote sensing, geographic information systems, and global positioning systems to monitor water quantity and water quality at WRATB. There are 12 water quality monitoring stations and four water gauge stations at WRATB. The coordinates of the 16 stations were determined by GPS devices and created into the base maps. MapObjects and visual BASIC were implemented to create application modules for water quality and quantity monitoring. Water quality of the two major watersheds at WRATB was put on Internet for public review monthly. The GIS software, ArcIMS, can put location maps and attributes of all 16 stations on Internet for general public review and technical implementations at WRATB. Inquiry and statistic charts automatic manipulations for the past 18 years are also available. Garbage disposal by community and tourist were also managed by GIS and GPS. The storage, collection, and transportation of garbage were reviewed by ArcMap file format. All garbage cart and garbage can at WRATB can be displayed on the base maps. Garbage disposal by tourist during holidays and weekends can be managed by a PDA with a GPS device and a digital camera. Man power allocation for tourist garbage disposal management can be done in an integration of GIS and GPS. Monitoring of water quality and quantity at WRATB can be done on Internet and by a PDA.

  • PDF

전기선로전환기 모니터링시스템의 성능 향상에 관한 연구 (Study on performance improvement of electric-point machine monitoring system)

  • 박재영
    • 한국산학기술학회논문지
    • /
    • 제11권11호
    • /
    • pp.4509-4514
    • /
    • 2010
  • 본 논문에서는 전기선로전환기의 유지보수 방법을 개선하기 위해 당초 연구 개발한 선로전환기 모니터링시스템을 시험 운용한 결과 보수방법 향상 효과를 확인 할 수 있었다. 그러나 보수자가 배치되지 않은 무인 연동역의 경우 선로전환기 장애 발생 시 또는 유지보수를 위하여 현장에 출동하기 전 까지는 보수 및 점검이 불가능하였다. 이러한 문제점을 개선하기 위하여 모니터링시스템에 원격지 컴퓨터와 통신할 수 있는 제어 모듈을 내장하여 선로전환기 전환 시에 원격지 컴퓨터에서 명령하는 제어정보를 수신하고 선로전환기가 전환된 후의 표시 정보 및 특히 장애 발생시의 상태를 모니터링시스템에 표출하도록 구성하여 원격지에서 관리할 수 있도록 성능을 향상시킴으로써 장애발생시 신속한 대응 체계 구축으로 유지보수의 효율성 및 편의성이 증대 될 것으로 예상된다.

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • 한국의학물리학회지:의학물리
    • /
    • 제32권2호
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Applications of Drones for Environmental Monitoring of Pollutant-Emitting Facilities

  • Son, Seung Woo;Yu, Jae Jin;Kim, Dong Woo;Park, Hyun Su;Yoon, Jeong Ho
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • 제2권4호
    • /
    • pp.298-304
    • /
    • 2021
  • This study aimed to determine the applicability of drones and air quality sensors in environmental monitoring of air pollutant emissions by developing and testing two new methods. The first method used orthoimagery for precise monitoring of pollutant-emitting facilities. The second method used atmospheric sensors for monitoring air pollutants in emissions. Results showed that ground sample distance could be established within 5 cm during the creation of orthoimagery for monitoring emissions, which allowed for detailed examination of facilities with naked eyes. For air quality monitoring, drones were flown on a fixed course and measured the air quality in point units, thus enabling mapping of air quality through spatial analysis. Sensors that could measure various substances were used during this process. Data on particulate matter were compared with data from the National Air Pollution Measurement Network to determine its future potential to leverage. However, technical development and applications for environmental monitoring of pollution-emitting facilities are still in their early stages. They could be limited by meteorological conditions and sensitivity of the sensor technology. This research is expected to provide guidelines for environmental monitoring of pollutant-emitting facilities using drones.

HACCP 적용 학교 급식소의 조리종사자 대상 위생교육 프로그램 개발 (Developing Food Safety Education Program for Employees at School Foodservice Implementing HACCP)

  • 이혜연;배현주
    • 대한지역사회영양학회지
    • /
    • 제21권1호
    • /
    • pp.84-92
    • /
    • 2016
  • Objectives: This study was performed to develop a food safety education program for school foodservice employees and evaluate its effectiveness. Methods: Food safety education programs were made into two levels; one for new employees in school foodservice and another for employees in charge of Critical Control Point (CCP) monitoring. The programs were for 40-minute-long lecture using PowerPoint. The effectiveness of these programs were assessed based on eleven evaluation items by school foodservice dieticians (n=30) and the Hazard Analysis Critical Control Point (HACCP) specialist (n=13). All statistical analyses are conducted by SPSS package program (ver 20.0). Results: According to the results of evaluating the food safety education program by dietitian and HACCP specialist, the overall satisfaction score was 4.14, evaluated by 5 point scale. There were no significant difference in results of evaluation between dieticians and HACCP specialists. The score of 'it is helpful to work' and 'pictures, images and charts are pertinent to study' were higher than others while the score of 'education contents is pleasant and interesting' and 'screen is pleasant and interesting' were the lowest among all evaluation items. Conclusions: To increase the school foodservice quality, employees should be offered regular food safety education and training through effective education media including prerequisite program and HACCP manual for school foodservice.

수위-유속 분산 그래프를 통한 하수흐름 특성 분석 (Sanitary sewer flow characteristics through a depth-velocity scatter graph analysis)

  • 손주영;오재일
    • 상하수도학회지
    • /
    • 제28권6호
    • /
    • pp.647-655
    • /
    • 2014
  • To perform long-term sewer monitoring, It is important to understand the nature of the wastewater flow that occurs at the point on early stage of the monitor and to prevent in advance a problem which may caused. We can infer the flow properties and external factors by analyzing the scatter graph obtained from the measured data flow rate monitoring data since an field external factor affecting the sewage flow is reflected in the flow rate monitoring data. In this study, Selecting the three points having various external factors, and we Inferred the sewer flow characteristics from depth-velocity scatter graph and determined the analysis equation for the dry-weather flow rate data. At the'point 1' expected non-pressure flow, we were able to see the drawdown effect caused by the free fall in the manhole section. At the'point 2', existed weir and sediments, there was backwater effect caused by them, and each of size calculated from the scatter graph analysis were 400 mm and 130 mm. At the'Point 3', there is specific flow pattern that is coming from flood wave propagation generated by the pump station at upstream. In common, adequate equations to explain the dry weather flow data are flume equation and modified manning equation(SS method), and the equations had compatibility for explaining the data because all of $R^2$ values are over 0.95.