• Title/Summary/Keyword: Monitoring Period

Search Result 1,698, Processing Time 0.032 seconds

Significance of Intracranial Pressure Monitoring in Early Surgery for Poor-Grade Aneurysm Patients (중증 뇌동맥류 환자의 조기 수술에 있어서 뇌압 측정의 중요성)

  • Kim, Sang Su;Kim, Jong Moon;Kang, Sung Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.425-429
    • /
    • 2001
  • Objective : Patients with poor grade aneurysm usually present with increased intracranial pressure(ICP), even those without an intracranial clot. Based on this fact, the present study investigated a significance of intracranial pressure monitoring in those patients. Patients and Methods : A total of 60 patients with Hunt and Hess Grade IV(50 patients) or V(10 patients) were treated for aneurysmal subarachnoid hemorrhage(SAH) during a 3-year-period, and intraparenchymal ICP was measured in the majority, immediately after arrival to the emergency room. Early surgery including intraoperative ventriculostomy was undertaken within 3 days after SAH. An ultraearly surgery was performed without preceding angiogram or ICP monitoring in patients with large sylvian hematomas, highly suggestive of middle cerebral artery aneurysm. Outcomes were assessed by the Glasgow Outcome Scale(GOS) at 6 months. Results : In overall, favorable outcome(GOS scores 1-2) was seen in 27(54.0%) of admission Grade IV and 1(10.0%) of admission Grade V patients. Of the 38 surgical patients with preoperative ICP monitorings, 25 patients (80.6%) exhibiting ICP values of less than 40mmHg showed favorable outcome, however, no patients with ICP values above 40mmHg recovered(Fisher's exact test, p=0.0001). Conclusion : It is concluded that a preoperative ICP above 40mmHg before ventriculostomy indicate significant vital brain destruction as intractable intracranial hypertension, and Grade IV patients at admission with an ICP below 40mmHg can be of benefit from early surgical intervention while Grade V patients still remains unfavorable.

  • PDF

Feasibility of Vegetation Temperature Condition Index for monitoring desertification in Bulgan, Mongolia

  • Yu, Hangnan;Lee, Jong-Yeol;Lee, Woo-Kyun;Lamchin, Munkhnasan;Tserendorj, Dejee;Choi, Sole;Song, Yongho;Kang, Ho Duck
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.6
    • /
    • pp.621-629
    • /
    • 2013
  • Desertification monitoring as a main portion for understand desertification, have been conducted by many scientists. However, the stage of research remains still in the level of comparison of the past and current situation. In other words, monitoring need to focus on finding methods of how to take precautions against desertification. In this study, Vegetation Temperature Condition Index (VTCI), derived from Normalized Difference Vegetation Index (NDVI) and Land Surface Temperature (LST), was utilized to observe the distribution change of vegetation. The index can be used to monitor drought occurrences at a regional level for a special period of a year, and it can also be used to study the spatial distribution of drought within the region. Techniques of remote sensing and Geographic Information System (GIS) were combined to detect the distribution change of vegetation with VTCI. As a result, assuming that the moisture condition is the only main factor that affects desertification, we found that the distribution of vegetation in Bulgan, Mongolia could be predicted in a certain degree, using VTCI. Although desertification is a complicated process and many factors could affect the result. This study is helpful to provide a strategic guidance for combating desertification and allocating the use of the labor force.

Battery-less Pork Freshness Monitoring Based on High-Efficiency RF Energy Harvesting

  • Nguyen, Nam Hoang;Lam, Minh Binh;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.293-302
    • /
    • 2020
  • Food safety has emerged as a growing concern for human health in recent times. Consuming contaminated food may lead to serious health problems, and therefore, a system for monitoring food freshness that is both non-detrimental to the quality of food and highly accurate is required to ensure that only high-quality fresh food packages are provided to the customers. This paper proposes a method to monitor and detect food quality using a compact smart sensor tag. The smart tag is composed of three ultra-low-power sensors, which monitor four major indicators of food freshness: temperature, humidity, and the concentrations of ammonia and hydrogen sulfide gases. An RF energy scavenging circuit is integrated into the smart sensor tag to harvest energy from radio waves at a high frequency of 13.56 MHz to supply sufficient power to the tag. Experimental results show that the proposed energy harvester can efficiently obtain energy at a distance of approximately 40 cm from a 4 W reader. In addition, the proposed smart sensor tag can operate without any battery, thereby eliminating the requirement of frequent battery replacement and consequently decreasing the cost. Meanwhile, the freshness of preserved pork is continuously monitored under two conditions--room temperature and refrigerator temperature--both of which are the most common temperatures under which food is generally stored. The food-monitoring experiments are conducted over a period of one week using the proposed battery-less tag. Based on the experimental results, the food assessment is classified into four categories: fresh, normal, low, and spoiled.

On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002 (지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징)

  • Kim C.-H;Park I.-S;Lee S.-J;Kim J.-S;Jin H.-A;Sung H.-G
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Investigation on the Validation for Designating Air Quality Control Region among Provincial Cities by the Data Measured with Air Quality Monitoring Network (대기오염 측정 자료에 의한 지방도시의 대기환경규제지역 설정에 관한 타당성 검토)

  • Yu, Mee-Seon;Yang, Sung-Bong;Woo, Kyung-Bin
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.181-190
    • /
    • 2016
  • Regional air quality regulation is a system that allows the Minister of Environment to designate the local area as air quality control region where the concentrations of air pollutants are exceeding the environmental standards, and the local governments that administrate the regulated area have to develop and practise a plan for reducing the air pollutants. From the data observed yearly by the monitoring stations in 8 provincial cities with more than 0.5 million people was judged the compliance with air quality standards in each municipality for the period of 2003 to 2013. As the result of investigation on air pollutants concentrations of each city, it was found that there was no station that exceeds the ambient air quality standards of CO, $SO_2$ and 24-hour $NO_2$. But all municipalities exceeded the standards of 8-hour $O_3$, annual and 24-hour $PM_{10}$, and therefore 8 municipalities can be designated to be under the local air regulation. For the annual $NO_2$ were the monitoring sites necessary requirements for designation of the air quality regulation region in Cheongju, Cheonan, Daejeon and Gwangju area. Incase of 1-hour $O_3$, some of stations in Pohang, Cheongju, Cheonan and Changwon area were over the designation standards for the air quality control region.

ICCP Control and Monitoring System for Ships

  • Oh, Jin-Seok;Moon, Serng-Bae
    • Journal of Navigation and Port Research
    • /
    • v.30 no.4
    • /
    • pp.291-294
    • /
    • 2006
  • Corrosion is never avoided in the use rf materials with various environments. The underwater hull is normally protected against rusting by several coatings of anti-corrosive paint. The purpose of ICCP(Impressed Current Cathodic Protection) system is to eliminate the rusting or corrosion, which occurs on metal immersed in seawater. This thesis is about the ICCP control and monitoring system, which brings protection against the corrosion of the ship's hull in the sea environments. The test system for ICCP is composed of a power supply, anode, reference electrode and controller. The test system is composed power supply, anode, ref electrode, shunt and etc. The protection current is sent to the protection area though anode. Reference electrode senses whether or not the detected potential is within a range of protection of test equipment and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode by controller. The monitoring system with LabView is also detected in order to check the normal state of the system at operation period, because an operator does not always watch over this system and thus the system cannot operate well because rf his or her negligent management. This paper was studied the variation of potential and current density with environment factors, velocity and time, and the experimental results will be explained Also, It is suggested that this system can accommodate a ship's automation for SCMS(Ship Control and Management System) and will be very useful.

Analysis of the temporal stratification variation pattern in Mikawa Bay, Japan (일본 미카와만의 시간적인 성층변화 양상 분석)

  • Cho, Hong-Yeon;Cho, Bong-Sik
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.3
    • /
    • pp.171-180
    • /
    • 2010
  • Analysis on the temporal variation of the stratification is carried out by using the continuous water temperature and salinity data observed in the coastal monitoring buoy in Mikawa Bay, Japan. The main analysis results are as follows. The stratification pattern have an obvious and dominant 1-year period variation and the occurrence frequency (days) are exponentially decreased as the stratification intensity (SI) defined as the density difference between surface and bottom layers linearly increases. The frequency distribution function of the SI is presumably close to the log-normal function type or exponential function type. From the water temperature and salinity scatter diagram analysis, the line and loop type patterns are shown in the bottom and surface layers, respectively. In addition, the analysis of the SI estimation show that the error bound in case of using the weekly-monitoring data is about 4.45 times greater than that in case of using the continuous (daily) monitoring data.

Evaluation of Ubiquitous High Blood-Pressure Demonstration in Sungnam (성남시 유비쿼터스 고혈압 관리에 대한 평가)

  • Lee, Won-Jae;Kim, Hye-Jung;Lee, Jae-Eun
    • Korean Journal of Health Education and Promotion
    • /
    • v.25 no.1
    • /
    • pp.13-23
    • /
    • 2008
  • Objective: The current study was to test if the developed sphygmomanometer was working well and blood pressure information could be collected and monitored systematically through the internet. We tested if the sphygmomanometer and services for blood pressure controlled high blood pressure significantly and the ubiquitous monitoring could be used further. Methods: Kyungwon University, KT Co., Gil Medical Center, LIG Nex1 Co., and Sujeong Health Center conducted an ubiquitous high blood control project in Sujeong-gu, Sungnam, Korea from Mar. 5 to May 16. We developed and applied sphygmomanometer. We distributed the devices to 27 high blood pressure patients. The blood pressures of the residents were monitored through the internet when they measured blood pressures in their homes. A nurse monitored and consulted their blood pressures in the monitoring center in Kyungwon University during the demonstration period. The consultant called them and consulted on their blood pressures in few seconds they used the sphygmomanometers. For the significance of change in blood pressure, we tested statistically with Generalized Additive Model(GAM) and Multi-level Analysis. Results: Both GAM and Multi-level Analysis showed that the blood pressures of persons with ubiquitous blood pressure management decreased significantly as time passed. Conclusions: The internet monitoring and services are considered to be promising because most of the participants were satisfied especially because somebody was caring their health. The decrease of blood pressures was significant by GAM and Multi-level Analysis. Thus, we can apply ubiquitous blood pressure management to health promotion projects.

Analysis of the Segmental Reinforced Retaining Wall Behavior by Field Monitoring (현장계측을 통한 블럭식 보강토 옹벽의 거동분석)

  • Shin, Eun Chul;Lee, Chang-Seup
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.1
    • /
    • pp.3-15
    • /
    • 2004
  • Geogrid reinforced soil structures with segmental block facing have been increased since 1990's, because of the convenience of installation and the flexible appearance. In this paper, the behavior of the segmental reinforced retaining wall was analysed with the results of field monitoring. The height and length of reinforced wall are 12m and 25m, respectively. The field measurement equipments are horizontal and vertical earth pressure cells, settlement plate, strain gauge, inclinometer, and displacement pin. Based on the field monitoring, the horizontal earth pressure was approximately 0.3times higher than that of the theoretical method and the maximum tensile strength of reinforcement was 26.2kN/m. The displacement of facing wall was 23mm at the point of 7.1m height of the wall and toward the wall facing. The results of the study indicate that the segmental reinforced retaining wall is in a stable condition because of good compaction & reinforcement effects, and long period of construction time. Finally, the computer program of SRWall is very useful tool to design the segmental reinforced retaining wall.

  • PDF