• 제목/요약/키워드: Monitoring Data

검색결과 8,880건 처리시간 0.045초

LabView를 이용한 풍력발전 성능평가용 모니터링 시스템 개발 (The Development of the Monitoring System for Power performance using the Lab View)

  • 고석환;장문석;주영철;이윤섭
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.69-74
    • /
    • 2009
  • Monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind turbine in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house, and of utilizing the measured data(fatigue data and electric analyzing data of wind turbine)for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind turbine during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system(BusDAQ) was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized. Also, This paper is introduced to make the best use of the developed monitoring system and to explain about construct of the system and detailed data communication of its system.

소형 독립형 풍력발전기의 진동 모니터링 및 분석 (Vibration Monitoring and Analysis of a Small Stand Alone Wind Turbine Generator)

  • 김석현;유능수;남윤수;이정완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.64-67
    • /
    • 2005
  • A vibration monitoring system for a small size wind turbine (WIT) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW stand alone WIT generator is investigated. Acceleration data of the WIT tower under various operation condition is acquired in real time using LabVIEW and the data are remotely transferred from the test site to the laboratory in school by internet. Vibration response characteristics of the tower structure are diagnosed in the aspect of stability of W/T. Wind data and electrical power performance are also investigated with the stability problem.

  • PDF

유비쿼터스 기반 통신의 철도구조물에 대한 재난감지용 능동형 데이터로거 시스템 연구 (A Study of Health & Disaster Monitoring Measurement using Ubiquitous Active Communication Digital Datalogger System for Railway Structures)

  • 이승원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.470-475
    • /
    • 2011
  • The objective of this study is the developement health & disaster monitoring measurement using ubiquitous active communication digital datalogger system for monitoring measurement of railway construction sites. For the replacement of current passive data communication, ubiquitous active communication digital datalogger system is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the global positioning automatic digital datalogger system. The results of this study will be using both real time automatic monitoring measurement and health & disaster monitoring measurement of railway structures.

  • PDF

Nonlinear PLS Monitoring Applied to An Wastewater Treatment Process

  • Bang, Yoon-Ho;Yoo, Chang-Kyoo;Park, Sang-Wook;Lee, In-Beum
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.102.1-102
    • /
    • 2001
  • In this work, extensions to partial least squares (PLS) for wastewater treatment (WWT) process monitoring are discussed. Conventional data gathered by monitoring WWT systems are usually time varying, high dimensional, correlated and nonlinear, PLS has been shown to be an efficient approach in modeling and monitoring high dimensional and correlated data. To represent dynamic and nonlinear features of the data several kinds of dynamic nonlinear PLS (DNLPLS) models have been proposed. However, the complexity and ambiguity of the models make them unsuitable for WWT monitoring, Recently, dynamic fuzzy PLS (DFPLS) was proposed ...

  • PDF

위험도로사면의 실시간 무인감시시스템 개발 연구 (A Study on Development of Automated Monitoring System for Road Cut Slopes)

  • 김춘식;이광우;윤수호;조삼덕
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.607-614
    • /
    • 2000
  • A cost-effective automated slope monitoring system is developed to monitor hazardous cut slopes along highways. This automated slope monitoring system consists of data-collection and visual monitoring, data-transmitting, database and internet service, and alarm system. Wire-line extensometer, automatic raingauge, and CCD camera are selected as monitoring instruments in this system, after consideration of failure characteristics of roadside cut slopes in the country. This paper describes the important features of this newly developed automated slope monitoring system.

  • PDF

전압 모니터링에 기반한 순간전압강하 확률적 추계 방법 (Stochastic Estimation of Voltage Sags Based on Voltage Monitoring)

  • 손정대;박창현
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1271-1277
    • /
    • 2018
  • This paper deals with a voltage sag assessment based on a voltage monitoring program. The voltage sag performance at a specific site can be evaluated by analyzing voltage monitoring data recorded for a long time period. Although an assessment based on voltage monitoring is an effective way to understand voltage sag performance at a measurement site, the statistical confidence of voltage sag frequency estimation heavily depends on the length of monitoring period and the number of recorded events. Short monitoring period and insufficient recorded data can not provide a reliable assessment result. This paper proposes a compensation assessment method by combining a computer simulation approach for in case that monitoring period and data are not enough for a valid assessment.

육상풍력실증연구단지 풍황계측 모니터링 시스템 개발 (The Development of the Monitoring System for Wind resource measurement in onshore wind energy experimental research complex)

  • 고석환;장문석;이윤섭
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.277-280
    • /
    • 2009
  • Wind monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind energy generator in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house and of utilizing the measured data for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind energy generator during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized, This paper is intended to explain the developed wind data monitoring system.

  • PDF

Development of integrated marine monitoring network on southern coastline of Caspian sea

  • Najafi-Jilani, A.;Nik-Khah, A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제3권2호
    • /
    • pp.136-140
    • /
    • 2011
  • Monitoring of water surfaces through permanent measurement of hydrodynamic and meteorological data is one of the main requirements in safe and sustainable water management. The Caspian Sea, the major surface water body in Iran, significantly affects more than 600 km of urban and industrial coastline. In the present work, an integrated marine monitoring network for the entire southern coastline of the Caspian Sea was developed. The main design concerns centered on the network measuring components and data recording, checking, filtering, gap recognition, and transferring systems. Four coastal monitoring stations were assigned, along with two regional collecting stations and one central data station for gathering, checking and delivering recorded data at different access levels. Applicable guidelines on selection of measuring devices for both shallow and deep water zones are presented herein.

반도체 공정의 SCRUBBER 감시 시스템 개발 (The Development of Monitoring System in the Scrubber of Semiconductor Manufacture Processing)

  • 김준환;김상우;김병진;문학룡;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2390-2392
    • /
    • 1998
  • In this paper, we discuss the development of monitoring system with data process equipment which transfers data from Remote Terminal Unit(RTU) to monitoring computer. The RTUs sense temperature, pressure and PLC(Programmable Logic Controller) nodes conditions of scrubber in semiconductor manufacture processing. The data Process equipment is connected every RTU and a monitoring computer through serial communication. This equipment receives informations from RTU, process data, and transfers them to monitoring computer. To avoid congestion in data communication, task scheduling algorithm used RT O/S(Real-Time Operating System) is embedded in ROM which is a part of data Process equipment.

  • PDF

가로등 원격감시 중앙관제시스템 개발 (Development of a Remote Central Monitoring System of Street Lights)

  • 하관용;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.43-45
    • /
    • 2004
  • A remote monitoring system was developed to improve inconveniences of manual work such as monitoring street lights by using current sensors, microprocessor and RF communication system. In order to control the street lights on the roads effectively and monitor them in real time, we can attach current sensor to the street lights which monitors Lamp, the broken part and state of the Balast, and the amount of an electric leak precisely we developed a system which makes it possible to transmit the data on monitoring results in breakdown of street lights and Balasts to the central monitoring computer without setting up extra data transmission line. The system we devised can transmit data through Power Line Modem and RF communication using relay method to the central controlling computer without any loss of data.

  • PDF