• 제목/요약/키워드: Monitoring: temperature

검색결과 2,274건 처리시간 0.034초

흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

광온도센서를 이용한 분전반의 온라인 진단 및 감시 (On-Line Diagnostics and Monitoring of Distribution Panel Using IR-Sensor)

  • 윤주호;최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2110-2111
    • /
    • 2008
  • Continuous on-line temperature monitoring allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF

배전설비의 온라인 모니터링과 진단 기술 동향 (A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments)

  • 임완수;이태우;여운철;이성길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

Modeling of temperature distribution in a reinforced concrete supertall structure based on structural health monitoring data

  • Ni, Y.Q.;Ye, X.W.;Lin, K.C.;Liao, W.Y.
    • Computers and Concrete
    • /
    • 제8권3호
    • /
    • pp.293-309
    • /
    • 2011
  • A long-term structural health monitoring (SHM) system comprising over 700 sensors of sixteen types has been implemented on the Guangzhou Television and Sightseeing Tower (GTST) of 610 m high for real-time monitoring of the structure at both construction and service stages. As part of this sophisticated SHM system, 48 temperature sensors have been deployed at 12 cross-sections of the reinforced concrete inner structure of the GTST to provide on-line monitoring via a wireless data transmission system. In this paper, the differential temperature profiles in the reinforced concrete inner structure of the GTST, which are mainly caused by solar radiation, are recognized from the monitoring data with the purpose of understanding the temperature-induced structural internal forces and deformations. After a careful examination of the pre-classified temperature measurement data obtained under sunny days and non-sunny days, common characteristic of the daily temperature variation is observed from the data acquired in sunny days. Making use of 60-day temperature measurement data obtained in sunny days, statistical patterns of the daily rising temperature and daily descending temperature are synthesized, and temperature distribution models of the reinforced concrete inner structure of the GTST are formulated using linear regression analysis. The developed monitoring-based temperature distribution models will serve as a reliable input for numerical prediction of the temperature-induced deformations and provide a robust basis to facilitate the design and construction of similar structures in consideration of thermal effects.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

현장계측 및 수치해석에 의한 장대버팀보의 온도영향 분석 (The Analysis of the Temperature Effects on Long-span Strut by Field Monitoring and Numerical Analysis)

  • 이문주;최성근;신세영;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1468-1475
    • /
    • 2005
  • In this study, the effects of temperature on loading of long-span strut were studied by using field monitoring and numerical analysis. For the field monitoring, several sensors, such as stain gages, temperature gages and load cells, were installed on the struts. From the monitoring results, the relation between temperature and axial force of the struts was analysed. By numerical analysis, the changes of axial force of strut and lateral displacement of wall due to temperature change were described with the strut length and ground conditions.

  • PDF

다중 온도 모니터링을 통한 충적층 및 하상의 지열특성 평가 연구 (A Study on Geothermal Evaluation of Alluvium and Riverbed using Thermal Line Temperature Monitoring)

  • 정우성;김형수;박동순;안영섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2006
  • In advanced countries, state-of-the-art temperature monitoring technique is widely used for effective use of geothermal resources. But these kind of modern tools such as Thermal Line Sensor has not been applied to find geothermal characteristics of alluvium and riverbed in domestic area. In this research, state-of-the-art thermal line temperature sensor monitoring was introduced. And long term field test using this type of sensor was performed to find geothermal characteristics of alluvium and riverbed and evaluate the availability for heat energy source. As a result, temperature monitoring technique through thermal line sensor was very effective to obtain basic geothermal information of alluvium deposit and riverbed. Also, it was found that the groundwater temperature phase showed its potential of utilization as a energy source of heat pump. It is estimated that further study shows a specific corelation between temperature monitoring data and its availability as a energy source.

  • PDF

NOAA/AVHRR 자료 응용기법 연구 - 운정.지표온도, 반사도, 해수면 온도, 식생지수, 산불, 홍수 분석 - (A Study on the Application of NOAA/AVHRR Data -Analysis of cloud top and surface temperature,albedo,sea surface temperature, vegetation index, forest fire and flood-)

  • 이미선;서애숙;이충기
    • 대한원격탐사학회지
    • /
    • 제12권1호
    • /
    • pp.60-80
    • /
    • 1996
  • AVHRR(Advanced Very High Resolution Radiometer) on NOAA satellite provides data in five spectral, one in visible range, one in near infrared and three in thermal range. In this paper, application of NOAA/AVHRR data is studied for environment monitoring such as cloud top temperature, surface temperature, albedo, sea surface temperature, vegetation index, forest fire, flood, snow cover and so on. The analyses for cloud top temperature, surface temperature, albedo, sea surface temperature, vegetation index and forest fire showed reasonable agreement. But monitoring for flood and snow cover was uneasy due to the limitations such as cloud contamination, low spatial resolution. So this research had only simple purpose to identify well-defined waterbody for dynamic monitoring of flood. Based on development of these basic algorithms, we have a plan to further reseach for environment monitoring using AVHRR data.

Wireless health monitoring of stay cable using piezoelectric strain response and smart skin technique

  • Kim, Jeong-Tae;Nguyen, Khac-Duy;Huynh, Thanh-Canh
    • Smart Structures and Systems
    • /
    • 제12권3_4호
    • /
    • pp.381-397
    • /
    • 2013
  • In this paper, wireless health monitoring of stay cables using piezoelectric strain sensors and a smart skin technique is presented. For the cables, tension forces are estimated to examine their health status from vibration features with consideration of temperature effects. The following approaches are implemented to achieve the objective. Firstly, the tension force estimation utilizing the piezoelectric sensor-embedded smart skin is presented. A temperature correlation model to recalculate the tension force at a temperature of interest is designed by correlating the change in cable's dynamic features and temperature variation. Secondly, the wireless health monitoring system for stay cables is described. A piezoelectric strain sensor node and a tension force monitoring software which is embedded in the sensor are designed. Finally, the feasibility of the proposed monitoring technique is evaluated on stay cables of the Hwamyung Grand Bridge in Busan, Korea.

배전반 설비의 온라인 모니터링 및 진단 (On-Line Condition Monitoring and Diagnostics of Distribution Equipment)

  • 윤주호;임완수;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.525-526
    • /
    • 2007
  • Continuous on-line temperature monitoring provides the means to evaluate current condition of equipment and detect abnormality. It allows corrective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system.

  • PDF