FDS를 이용한 교번식 미분무방식의 소화 성능 분석 (Analysis for fire suppression efficiency of intermittent water spray pattern with FDS)

  • 지문학;이병곤
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.200-203
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively low and the infiltration of water mist to the fire source is not effective. In addition to lower penetration force, the evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist system is expected to improve the penetration force of water mist as well as the dilution coverage capability with the stratified spray characteristics. At this paper we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis shall be supportive to the development of the prototype of water mist nozzle.

  • PDF

FDS를 이용한 교번식 미분무방식의 소화 성능 분석 (Analysis of Fire Suppression Efficiency for Intermittent Water Spray Pattern by Fire Dynamics Simulator)

  • 지문학;이병곤
    • 한국화재소방학회논문지
    • /
    • 제22권3호
    • /
    • pp.216-220
    • /
    • 2008
  • 물분무소화설비는 화원의 냉각, 주변공기의 희석, 미세한 물방울의 증발에 의한 열차단과 같은 소화특성을 이용한다. 미분무수의 운동량은 입자가 큰 물방울에 비해 상대적으로 낮으며 화원의 침투능력도 효과적이지 못하다. 증발된 수증기에 의한 기여는 무게가 가볍고 밀도가 희박하여 화원에 일부분으로 제한되는 경향이 있다. 반면, 사이클식 미분무 패턴은 성층화된 분무 특성에 의해 공기 추출능력과 침투력이 개선될 것으로 예상된다. 이 논문에서는 유체공학적 화재모델인 FDS를 사용하여 교번식 미분무 패턴에 대해 분석된 소화능력을 다룬다. 저자는 이 분석이 미분무 노즐의 표본을 개발하기 위한 기본 개념을 제공할 수 있기를 기대한다.

수성막포 약제를 첨가한 미분무수의 식용유 화재 소화특성 (Extinguishing Characteristics of Cooking Oil Fire by Water Mist added with AFFF Agent)

  • 신창섭;김성룡
    • 한국안전학회지
    • /
    • 제24권5호
    • /
    • pp.21-27
    • /
    • 2009
  • Effective way of cooking oil fire extinguishment is using water mist system which has cooling and smothering effects. Low pressure water mist system has advantage because it is compatible with existing sprinkler systems. To increase the effectiveness of low pressure water mist system, additives can be used which increase the momentum of water particle and the chemical effect. In this experiment, aqueous film forming form(AFFF) agent is used as additive and the effect of additive concentration and water pressure are experimented. For the extinguishment of cooking oil fire such as soybean and olive oils, AFFF agent is effective and can decrease the fire extinguishing time and water consumption.

알칼리 금속염을 함유한 미분무수의 헵탄 Pool Fire 소화 (Extinguishment of n-heptane Pool Fire by Water Mist Containing Alkali Metal Agent)

  • 박재만;신창섭
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.105-111
    • /
    • 2005
  • An experimental study is performed for extinguishing of n-heptane pool fire by water mist containing potassium acetate as a fire suppression additive. Water mist was generated by a single pressure nozzle in a small-scale chamber. The drop size distribution of water mist was measured using laser diffraction(Malvern particle sizer). The flame temperature, oxygen concentration and carbon monoxide concentration were measured. In case of using additives, the fire extinguishing time was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

객차내 환기속도가 고압 미세물분무 화재제어 시스템 성능에 미치는 영향에 대한 실험적 연구 (An Experimental Study for the Effect of Ventilation Velocity on Performance of a High Pressure Water Mist Fire Suppression System)

  • 김동운;배승용;유홍선
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.1-6
    • /
    • 2008
  • This experiments are perfol1ned to investigate the effect of ventilation velocity on a high pressure water mist tire suppression in train. The experiment is conducted in half scale modeled train of a steel-welled enclosure (5.0m${\times}$2.4m${\times}$2.2m). The ventilation velocity is controlled by the ventilation duct through an inverter in the range of 0 to 3m/s. The coverage-radius and an injection angle of an high pressure water mist system are measured. The mist nozzle with 5-injection holes is operated with pressure 60bar. The heptane pool fires are used. The fire extinguishment times and the temperature are measured for the ventilation velocities. In conclusion, because the momentum of injected water mist is more dominant than that of ventilation air, the characteristics of water mist, the fire extinguishment times and the temperature are affected very little by ventilation velocity.

Recent Progress in Methods of Generating Water Mist for Fire Suppression

  • Guangxuan, Liao;Xin, Huang;Beihua, Cong;Jun, Qin;Jianghong, Liu;Xishi, Wang
    • 한국분무공학회지
    • /
    • 제11권4호
    • /
    • pp.251-265
    • /
    • 2006
  • To prevent the ozonosphere from being destroyed by Halon, it is an urgent task to find out Halon replacement. As one of the replacements water mist have showed broad applications by its advantages: little pollution to environment (not destroying the ozone layer or bring green house effect), extinguishing fire quickly, consuming a small quantity of water and having little damage to the protected objects. The methods of generating water mist strongly influence fire suppression effectiveness, which determine the cone angle, drop size distribution, flux uniformity, and momentum of the generating spray. The traditional water mist nozzle included pressure jet nozzles, impingement nozzles and twin-fluid nozzles. All of them have more or less disadvantages for fire suppression. Therefore, many research institutes and corporations are taking up with innovations in mist generation. This article provided some recent studies in State Key Laboratory of Fire Science (SKLFS) of University of Science and Technology of China. SKLFS have investigated new methods of generating water mist (i.e. effervescent atomization and ultrasonic atomization). and self developed a series of nozzles and developed advanced DPIVS (Digital Particle Image Velocimetry and Sizing) technique. Characteristics of water mist (the distribution of droplet sizes, flux density, spray dynamics and cone angle) produced by these nozzles were measured under different conditions (work pressure, nozzle geometry, etc.) using LDV/APV and DPTVS systems. A series of experiments were performed to study the fire suppression effectiveness in different fire scenario (different kindsof the fuel, fire size and ventilation conditions). The fire extinguishing mechanisms of water mist was also discussed.

  • PDF

지하철 객차 내 환기 속도가 고압 미세물분무 화재제어 시스템의 성능에 대한 실험평가 (An Experimental Evaluation for the Effect of Ventilation Velocity in Subway Train on Performance of a High Pressure Water Mist Fire Suppression)

  • 김동운;배승용;김동석;박원희;유홍선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1307-1312
    • /
    • 2007
  • This experiments are performed to investigate the effect of ventilation velocity on a high pressure water mist fire suppression in subway train. The experiment is conducted in half scale modeled train of a steel-welled enclosure (8.0m*2.4m*2.1m). The ventilation velocity is controlled by the ventilation duct through an inverter in the range of 0 to 2 m/s. The coverage-radius and an injection angle of an high pressure water mist system are measured. The mist nozzle with 7-injection holes is operated with pressure 80 bar. The heptane pool fires are used. The fire extinguishment times and the temperatures are measured for the ventilation velocities. In conclusion, because the momentum of injected water mist is more dominant than that of ventilation air, the characteristics of water mist, the fire extinguishment times and the temperatures are affected very little by ventilation velocity.

  • PDF

Extinguishment of Liquid Fuel Fire by Water Mist Containing Additives

  • Park, Jae-Man;Won, Jung-Il;Shin, Chang-Sub
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.24-29
    • /
    • 2005
  • An experimental study was presented for extinguishing characteristics of liquid fuel fire by water mist($Dv_{0.99}{\leq}200{\mu}m$) containing potassium acetate and sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing additives, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space. During the experiments, flame temperatures were measured, and concentrations of oxygen and carbon monoxide were analyzed by a combustion gas analyzer. The average evaporation rate of water droplet containing additives was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid-film and change of surface tension. In case of using additives, the fire extinguishing times was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium or sodium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4 MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

분무 증발을 이용한 칩 냉각 향상에 대한 수치적 연구 (NUMERICAL STUDY OF CHIP COOLING ENHANCEMENT WITH EVAPORATING MIST FLOW)

  • 노상은;김동철;손기헌
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.9-16
    • /
    • 2013
  • The heat transfer enhancement of heat sink with mist flow is studied numerically by solving the conservation equations for mass, momentum and energy in the continuous and dispersed phases. A Lagrangian method is used for tracing dispersed water droplets in the heat sink and an Eulerian species transport model for air and steam mixture. The continuous and dispersed phases are interacted with the drag and evaporation source terms. The computed results show that addition of evaporating mist droplets enhances the cooling performance of heat sink significantly.

나트륨 염이 첨가된 미분무수의 액체 pool fire소화특성 (Extinguishing Characteristics of Liquid Pool Eire by Water Mist Containing Sodium Salt)

  • 박재만;신창섭
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.13-19
    • /
    • 2005
  • 본 논문에서는 금속염 첨가제를 함유한 미분무수의 소화성능을 연구하고자 아세트산 나트륨을 함유한 단일 액적의 증발속도를 측정하였으며, small-scale 챔버내에서의 헵탄 pool fire에 대한 소화실험을 실시하여, 화염의 온도를 분석함으로써 첨가제에 의한 미분무수 소화특성을 분석하였다. 순수물과 수용액의 증발특성을 비교한 결과 핵비등 영역에서 온도가 높을수록 용해된 첨가제의 석출 및 표면장력의 변화 등 물리적 영향으로 순수물에 비해 수용액의 증발속도가 현저히 느리게 나타났다. 소화실험 결과, 저압에서는 물 액적이 화염의 플림을 뚫지 못하기 때문에 소화는 이루어지지 않았고 단순히 화염의 크기를 작아지게 하였다. 중압에서는 첨가제를 넣었을 경우 액적의 운동량 증가에 따른 물리적 소화효과와 첨가제의 화학적 소화효과가 상승작용을 하여 화염을 억제하였고, 고압에서는 미분무수 시스템의 주요 소화 메커니즘 이외에도 blowing효과에 의해서 화염이 소화되는 것을 관찰할 수 있었다.