• 제목/요약/키워드: Momentary stability

검색결과 12건 처리시간 0.032초

Energy Stability Analysis on the Onset of Buoyancy-Driven Convection in a Horizontal Fluid Layer Subject to Evaporative Cooling

  • Kim, Min Chan
    • Korean Chemical Engineering Research
    • /
    • 제57권1호
    • /
    • pp.142-147
    • /
    • 2019
  • The onset of buoyancy-driven convection in an initially isothermal and quiescent horizontal fluid layer was analyzed theoretically. It is well-known that at the critical Rayleigh number $Ra_c=669$ convective motion sets in with a constant-heat-flux cooling through the upper boundary. Here, based on the momentary instability concept, the dimensionless critical time ${\tau}_m$ to mark the onset of convective motion for Ra > 669 was analyzed theoretically. The energy method under the momentary stability concept was used to find the critical conditions as a function of the Rayleigh number Ra and the Prandtl number Pr. The predicted critical conditions were compared with the previous theoretical and experimental results. The momentary stability criterion gives more reasonable wavenumber than the conventional energy method.

전력계통의 전압안정도향상을 위한 감시제어시스템 개발 (A Development of Monitoring and Control System for Improved the Voltage Stability in the Power System)

  • 이현철;정기석;박지호;백영식
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.437-443
    • /
    • 2013
  • This paper was developed a monitoring and control system to use reactive power control algorithm. This algorithm could be improved voltage stability in power system. This method was controlled the voltage for stability improvement, effective usage of reactive power, and the increase of the power quality. PMS(Power Management System) has been calculate voltage sensitivity, and control reactive power compensation device. The voltage control was used to the FACTS, MSC/MSR(Mechanically Switched Capacitors/Reactors), and tap of transformer in power system. The reactive power devices in power system were control by voltage sensitivity ranking of each bus. Also, to secure momentary reactive power, it had been controlled as the rest of reactive power in the each bus. In here, reactive power has been MSC/MSR. The simulation result, First control was voltage control as fast response control of FACTS. Second control was voltage control through the necessary reactive power calculation as slow response control of MSR/MSR. Third control was secured momentary reactive reserve power. This control was method by cooperative control between FACTS and MSR/MSC. Therefore, the proposed algorithm was had been secured the suitable reactive reserve power in power system.

Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding

  • Niaz, Atif Khan;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권3호
    • /
    • pp.369-376
    • /
    • 2022
  • In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in an on-off cycling operation with respect to an applied electric bias, i.e., a current density of 500 mA cm-2, and an open circuit. The ohmic and polarization resistances of the system were monitored during operation (~800 h) using electrochemical impedance spectra. Specific consideration was given to the ohmic resistance of the cell, especially that of the membrane under on-off cycling conditions, by consistently feeding the cell with KOH solution. Owing to an excess feed solution, a momentary increase in the polarization resistance was observed immediately after the open-circuit. The excess feed solution was mostly recovered by subjecting the cell to the applied electric bias. Stability tests on the AEMWE cell under on-off cycling with continuous feeding even under an open circuit can guarantee long-term stability by avoiding an irreversible increase in ohmic and polarization resistances.

Fuzzy Estimation for Fault Location

  • Tipsuwanporn, V.;Tuppadung, Y.;Suesut, T.;Rukkaphan, S.;Junkrob, N.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.453-453
    • /
    • 2000
  • This paper presented Fuzzy logic application to Electrical power system analysis for fault location estimation in distribution lines and apply the Power system theory to be fuzzy logic database. The case study referred to the Overhead distribution line of the Provincial Electricity Authority (PEA.), Thailand which mostly the distribution line of PEA. are Radial schemes. These benefits include reduced outage time, help in locating momentary faults, enhance safety to the line crews and provide notification of an outage without receiving calls from the consumer, Which these benefits also increase Reliability, Stability and Efficiency.

  • PDF

Tracing Resistances of Anion Exchange Membrane Water Electrolyzer during Long-term Stability Tests

  • Niaz, Atif Khan;Lee, Woong;Yang, SeungCheol;Lim, Hyung-Tae
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권3호
    • /
    • pp.358-364
    • /
    • 2021
  • In this study, an anion exchange membrane water electrolysis (AEMWE) cell was operated for ~1000 h at a voltage bias of 1.95 V. Impedance spectra were regularly measured every ~ 100 h, and changes in the ohmic and non-ohmic resistance were traced as a function of time. While there was relatively little change in the I-V curves and the total cell resistance during the long-term test, we observed various electrochemical phenomena in the cell: 1) initial activation with a decrease in both ohmic and non-ohmic resistance; 2) momentary and non-permanent bubble resistance (non-ohmic resistance) depending on the voltage bias, and 3) membrane degradation with a slight increase in the ohmic resistance. Thus, the regular test protocol used in this study provided clear insights into the performance degradation (or improvement) mechanism of AEMWE cells.

PSCAD/EMTDC를 이용한 Micro-SMES의 시뮬레이션 (Simulation of Micro-SMES System using PSCAO/EMTOC)

  • 김봉태;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1361-1363
    • /
    • 2002
  • Micro-SMES(Superconducting Magnetic Energy Storage) has been studied as an impulsive high power supply for industrial applications. Recently, electric power reliability of our country has been improved. However, there are still remaining problems which are short-duration variations like instantaneous and momentary interruption and voltage sag by nature calamity ; typhoon, lightning, snow, etc. Besides, power quality ; harmonics, goes down because of using power electronics equipments. Malfunction of controller and stop machinery, and losing important data are caused by poor power quality at a couple of second in accuracy controllers. Due to those, battery based UPS has been used, but there are several disadvantages ; long charge and discharge time, environmental problem by acid and heavy metal, and short life time. Micro-SMES is an alternative to settle problems mentioned above. However, there need huge system apparatuses in order to verify the effect of system efficiency and stability considering the size of micro-SMES, the sort of converter type, and various conditions. This paper presents a cost effective simulation method of micro-SMES and power converter, and design for micro-SMES based system using PSCAD/EMTDC.

  • PDF

Micro SMES를 이용한 전원공급 안정화장치 시뮬레이션을 위한 PSCAD/EMTDC 컴포넌트 모델링 (Component Modeling of Micro SMES Based Design of Stabilizer Simulation for Power Supply using PSCAD/EMTDC)

  • 김봉태;박민원;성기철;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.228-230
    • /
    • 2002
  • Recently, electric power reliability of our country has been improved. However, there are still remaining problems which are short-duration variations like instantaneous and momentary interruption and voltage sag by nature calamity ; typhoon, lightning, snow, etc. Besides, power quality ; harmonics, caused by using power electronics equipments, become a hot issue Malfunction of controller and stop machinery, and losing the important data are caused by poor power quality at a couple of second. Due to those, UPS, which is made up battery, has being used, but there are several disadvantages ; long charge and discharge time, environmental problem by acid and heavy metal, and short life time. As generally know, micro-SMES is a method to settle those mentioned. However, there need huge system apparatuses in order to verify the effect of system efficiency and stability considering the size of micro-SMES, the sort of converter type, and various conditions ; inner temperature, magnetic field, quench characteristic of micro-SMES, and etc. In this paper, in order to bring the mentioned above to a settlement, a micro-SMES is modeled with characteristics of micro-SMES is interfaced to EMTOC program using Fortran program interface method. We obtained hopeful answers and made the simulation model of micro SMES.

  • PDF

하이브리드 로켓 연소실험에서의 고주파수 진동과 저주파수 연소불안정 (High Frequency Oscillations and Low Frequency Instability in Hybrid Rocket Combustion)

  • 채희상;이창진
    • 한국항공우주학회지
    • /
    • 제46권12호
    • /
    • pp.1021-1027
    • /
    • 2018
  • 하이브리드 로켓에서 고주파수 대역의 압력진동(p')과 열 방출 진동(q')이 양의 결합이 저주파수 연소불안정 발생에 필수조건임을 검증하기 위한 실험연구를 수행하였다. 후연소실 길이와 연소 당량비를 변수로 설정하여 p' 진폭과 p', q'의 위상차를 조절하였으며 저주파수 연소불안정의 억제 여부를 판단하였다. 실험 결과에 의하면, 후연소실 길이가 증가하여도 p', q'의 위상차는 ${\pi}/2$ 이하로 연소불안정 발생조건을 유지하지만 p', q'의 결합강도인 RI(Rayleigh index)의 주기적 증폭이 약화되면서 연소불안정이 억제됐다. 또한 특정한 당량비에서 연소불안정이 발생하므로 순간 당량비를 변화시켜 p', q'의 결합을 음의 결합으로 천이시켜 연소 안정화가 이루어짐을 확인하였다. 따라서 고주파수 p', q'이 양의 결합과 RI의 주기적인 증폭으로 연결될 때 저주파수 연소불안정이 나타나는 발생 메커니즘의 중간 경로도 확인하였다.

전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가 (Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger)

  • 강형섭;홍영표;이인호;김기범
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.558-566
    • /
    • 2017
  • 본 연구는 MOSFET을 이용하여 안정적인 구형파를 구현함과 동시에 순간적인 전류의 상승을 최대한 줄여 전체 회로의 안정성 이 확보된 폐수처리용 전자방사식 OH radical generator를 개발하고자 하였다. 이와 같은 문제를 해결하고 안정성이 확보된 전자방사식 고압 저전력 방전을 이용한 폐수처리용 전자방사식 OH radical generator를 개발하고 그 성능을 평가하고자 하였다. 실험은 2016년 11월부터 2017년 3월까지 실시하였다. 그 결과 AC 체배 변환기의 입력 단에 연결되는 Power MOSFET의 drain 전류는 CR-스너버 구조의 부궤환(negative feedback) 회로를 통해 안정적이고 일정한 펄스 파형을 제공할 수 있었으며 AC 체배 변환기의 여기 전류(excitation current) 감소 및 발진 회로의 안정성을 상승시킬 수 있었다. 또한 이와 같은 회로를 갖는 전자방사식 OH radical generator에서 OH radical을 안정정적으로 발생시킬 수 있었다. 또한 살균능을 평가한 결과, E. coli, S. aureus와 S. flexneri는 60분 후 최대 99.9%이상의 살균력을 보였다. 본 연구 결과를 기반으로, MOSFET을 이용하여 안정적인 구형파를 구현함과 동시에 순간적인 전류의 상승을 최대한 줄여 전체 회로의 안정성이 확보된 살균능이 우수한 폐수처리용 전자방사식 OH radical generator를 개발하였다.

내장산국립공원(內藏山國立公園)의 식물군집(植物群集) 및 이용행태(利用行態)에 관한 연구(硏究)(II) -이용객(利用客) 영향(影響) 및 행태(行態)- (Studies on the Structure of Plant Community and Visitor's Activities in Mt. Naejang National Park(II) -User's Impact and Activity-)

  • 이경재;오구균;조재창
    • 한국산림과학회지
    • /
    • 제77권4호
    • /
    • pp.401-413
    • /
    • 1988
  • 내장산국립공원 내장사지구의 이용객심리행태 및 환경에 대한 이용객영향을 조사하기 위해서 3개의 주요피크닉지역에서 설문조사와 순간밀도조사를, 주요통과지점에서 출입객 수 조사를 하였으며 환경영향은 실측조사를 하였다. 총탐방객 수는 1984년부터 100만명/연 수준으로 안정을 보이고 있었다. 환경영향은 등산로와 케이블카 종점부근, 전망대와 금선계곡간 사면에서 매우 심하였다. 봄철 피크시에는 약 5,000명, 가을 단풍철 피크시에는 약 53,000 명이 동시에 체류하는 것으로 추정되었다. 총입장객 중 약20% 가금선 및 원적계곡을 이용하였고, 나머지 80%는 잔디광장, 케이블카만 이용하고 퇴장하는 것으로 나타났다. 이용특성은 원거리형 국립공원형이었으며, 가을철 단풍구경이 주이용동기이었다. 이용면적증가에 따른 이용객의 만족도는 유의하게 차이를 나타내지 않았으며, 직각회전방법에 의한 인자분석결과, 이용객의 만족도에 크게 영향을 미치는 제1인자는 주변경관에 관한 인자로 자연파괴, 혼잡도, 소음, 주변청결상태 순으로 부하되어 있었다. 다음으로 영향을 미치는 제2인자는 시설관리인자로서 화장실 수, 쓰레기통 수, 식수량, 안전성 순으로 부하되어 있었다.

  • PDF