• 제목/요약/키워드: Moment frame apartment

검색결과 4건 처리시간 0.018초

벽식구조 공동주택의 바닥충격음 개선에 대한 연구 (A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment)

  • 김선우
    • KIEAE Journal
    • /
    • 제12권1호
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

공동주택 적용을 위한 친환경 라멘구조 접합부 개발 (Development of Beam-Column Connection for Green Rhamen Structural Apartment)

  • 윤태호;홍원기;박선치;윤대영
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.159-165
    • /
    • 2010
  • The composite frame system suggested in this paper consists of steel reinforced concrete beam encased with structural tee and precast concrete column. This system has advantages such as reduction of materials, CO2 emissions and waste. To commercialize the new composite frame system, it is necessary to develop connections that can effectively connect each member. Therefore, a hybrid connection that has steel type connection and reinforced concrete together is utilized to connect easily at the composite frame system. To evaluate the structural performance of the composite frame system, an experimental investigation is presented. In this study, the flexural moment capacity of the composite frame was determined using the strain compatibility approach. The strain compatibility approach can be used to predict the flexural moment capacity at each limit state. As a result, all elements of the beam to column connection are represented to fully interact between each other. The specimens show errors of -1.9% in the yield limit state and 0.9% at the maximum load limit state. Also, testing shows that beam to column connections have characteristics of semi-rigid connection as per Eurocode 3.

선형해석방법을 이용한 철골 모멘트골조의 붕괴저항성능 (Collapse-Resisting Capacity of Steel Moment Frames Using the Linear Elastic Analysis)

  • 김진구;양정호;김태완
    • 한국전산구조공학회논문집
    • /
    • 제20권4호
    • /
    • pp.435-442
    • /
    • 2007
  • 1968년 영국의 Ronan Point 아파트에서 발생한 연쇄붕괴 이후 이에 대한 연구가 간헐적으로 진행되어 왔으며, 최근 미국의 World Trade Center 붕괴 후 연쇄붕괴에 대한 연구가 다시 활발히 진행되고 있다. 미국에서는 기존의 연구결과를 바탕으로 2003년 GSA 및 2005년 DoD에서 연쇄붕괴에 대한 설계 및 해석 지침을 제시하였다. 본 연구에서는 이러한 지침서에서 제시하고 있는 선형정적해석법과, 선형동적해석법을 사용하여 국내 설계기준에 의해 설계된 철골 모멘트저항골조에 대한 붕괴저항 성능을 조사하였다. 해석결과에 따르면 GSA 기준을 적용할 경우 횡력을 고려하지 않은 수직저항시스템은 연쇄 붕괴에 취약한 것으로 나타났으나, 지진력을 고려하여 설계된 수평저항시스템은 연쇄붕괴에 대해 안전한 결과를 얻었다. 하지만 DoD 기준에 따르면 두 시스템 모두 연쇄붕괴에 취약한 것으로 나타났다.

깊은보-외부기둥 접합부의 반복 횡하중 실험 (Reversed Cyclic Load Tests on Deep Beam-and-Exterior Column Joints)

  • 고동우;이한선
    • 콘크리트학회논문집
    • /
    • 제19권3호
    • /
    • pp.265-273
    • /
    • 2007
  • 최근 우리나라의 공동주택 또는 주상복합 건물의 구조 시스템으로 상부 벽식 하부 골조의 복합구조 형태가 주로 사용되고 있다. 이와 같은 건물의 경우 상부층의 하중이 전이판 또는 깊은보의 형태를 띠는 깊은보를 통해 하부 골조로 전달되고, 횡력에 대해서는 하부 골조가 연층 또는 약층에 의한 파괴가 발생할 수 있기 때문에 횡력에 대한 깊은보와 기둥은 매우 중요하다. 본 연구에서는 이러한 깊은보와 하부 기둥이 만나는 부분에서 요구되는 강도, 연성 등을 파악하고자 깊은보-외부기둥 접합부에 대해 ACI의 중진지역 상세에 의한 방법과 Sheikh가 제안한 방법에 따라 기둥을 설계한 후, 1/2.5 축소 모델 실험에 대한 반복 횡하중 실험을 수행하였다. 그 결과는 다음과 같다. (1) Sheikh의 제안식에 따라 설계할 경우 요구 횡철근이 2.9배 증가하였으며, 이는 기둥의 연성이 증가하는 결과를 가져왔다. (2) 기둥 횡변 위는 대부분 소성힌지에서 휨변형, 접합부에서 휨변형, 그리고 들뜸에 의해 발생하였다. (3) 깊은보와 외부기둥이 접하는 경우 기둥의 상세 뿐만 아니라 접합부에서 과도한 변형을 방지하기 위해 접합부 내부에도 충분한 횡철근이 배근이 되어야 할 필요가 있었다.