• 제목/요약/키워드: Molded transformer

검색결과 24건 처리시간 0.02초

건식변압기 코일의 열적 수명평가 (Thermal Lifetime Estimation of Coil Used for Dry-type Transformer)

  • 김민규;허대행;김익수;장진영;문병철;고재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.131-132
    • /
    • 2008
  • This paper describes a method to estimate the thermal lifetime of coil used in the dry-type molded transformer which is widely used in the domestic distribution system. In order to reduce the testing time, temperature accelerated aging test is planned. Finally, the thermal lifetime estimation method is composed of a temperature aging test and a cyclic test of temperature, humidly and lightning impulse voltage withstand test.

  • PDF

반도체 변압기 및 스위치드 릴럭턴스 전동기(SRM)를 적용한 철도차량 추진제어 (Propulsion Control of Railway Vehicle using Semiconductor Transformer and Switched Reluctance Motor)

  • 정성인
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.127-132
    • /
    • 2022
  • 철도차량에 탑재된 전장품 중 가장 큰 하중을 차지하는 것은 주변압기로 낮은 운전 주파수(60Hz)로 인해 전력밀도가 0.2~0.4 MVA/ton 정도로 낮아 경량화에 중요한 요소로 작용하고 있다. 따라서 철도차량용 주변압기를 개선하기 위해 몰드 변압기, 반도체 변압기 등에 관한 연구가 국내외적으로 활발히 진행 중이다. 한편 국내외 철도차량에 대부분 적용되는 견인전동기로 최근에는 유도전동기를 대체하여 영구자석 동기전동기(PMSM)를 적용하려는 시도가 이루어지고 있다. 영구자석 동기전동기(PMSM)는 유도전동기에 비해 높은 출력밀도와 효율 확보가 가능하지만 제작에 필요한 재료의 가격이 비싸고 설계가 유도전동기 대비 다소 어렵다는 단점이 있다. 이러한 문제점을 고려하여 본 논문에서는 소형 경량화가 가능한 반도체 변압기를 적용하고, 철도차량의 경량화, 고효율화 등의 요구사항에 맞춰 구조가 간단하면서 회전수가 높고 고토크, 저비용인 SRM을 적용할 수 있는 연구내용을 제안하고자 한다.

저손실형 몰드 단권변압기 개발 (A study on the Development of Low-loss Type Mold Autotransformers)

  • 이종수;신명호;문병철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.92-94
    • /
    • 2003
  • The autotransformer currently used on the electric railway system is made of class A insulation material and uses the paper insulation method. As a power converter supplying power to the trolley wire, the autotransformer is one of critical equipment in the railway system. In the autotransformer, load irregularly changes and overload often occurs. These cause overheating of the autotransformer and facilitate deterioration of the autotransformer resulting in burnout accidents due to insulation breakdown. Also, the current autotransformer has poor insolation and short-circuit strength which often badly affect the service life of the transformer, and needs to improve its quality urgently. To overcome one of existing shortcomings of the mold transformer, manufacturers use epoxy resins that have superior flame retardancy to get rid of fro and explosion possibilities during accidents. Currently, new mold transformers are used in indoor distribution facilities with fire-fighting equipments. Coils molded in epoxy resins do not have their insulation performance compromised by humidity, dust, etc enabling easy inspection and maintenance. Comparing to the oil immersed transformer, the mold transformer does not have any concern about environmental pollutions by oil leak or replacement Therefore, to reduce breakdowns and improve reliability of the autotransformer, it is necessary to develop a new mold autotransformer with low loss suitable for our environment to suppress breakdowns of the autotransformer and improve the reliability. This study is about development of a low-loss mold autotransformer necessitated by reasons mentioned earlier.

  • PDF

탄소재 성형품에 대한 정밀 치수 검사 시스템에 관한 연구 (A Study on the System of the Precision Dimensional Measurements for Molded Product Carbon Materials)

  • 김대년
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.37-42
    • /
    • 2016
  • This paper proposes a method to develop a high-precision dimension measurement system using a linear variable differential transformer sensor. The Dimension targets for measurement is carbon material vanes of key element in the rotating parts within vehicle circulating pump. Data acquisition system for dimension measurement is designed using the NI Compact RIO. And the program applying the dimension measurement algorithm is built using NI LabVIEW. The dimension measuring program is composed of a FPGA program, Real Time program and Host program. The method of the experiment compares master vane with target vane for measure the length of the carbon material vane. The experimental results confirmed the usefulness of the accuracy within ${\pm}4um$.

배전용 몰드변압기 적용을 위한 EMNC의 교류절연파괴특성 연구 (AC Insulation Breakdown Properties of the EMNC to Application of Distribution Molded Transformer)

  • 박재준
    • 전기학회논문지
    • /
    • 제62권5호
    • /
    • pp.649-656
    • /
    • 2013
  • A conventional epoxy-microsilica composite (EMC) and an epoxy-microsilica-nanosilicate composite (EMNC) were prepared in order to apply them to mold-type transformers, current transformers (CT) and potential transformers (PT). Nanosilicate was exfoliated in a epoxy resin using our electric field dispersion process and AC insulation breakdown strength at $30{\sim}150^{\circ}C$, glass transition temperature and viscoelasticity were studied. AC insulation breakdown strength of EMNC was higher than that of EMC and that value of EMNC was far higher at high temperature. Glass transition temperature and viscoelasticity property of EMNC was higher than those of EMC at high temperature. These results was due to the even dispersion of nanosilicates among the nanosilicas, which could be observed using transmission electron microscopy (TEM). That is, the nanosilicates interrupt the electron transfer and restrict the mobility of the epoxy chains.

MCCB내부 금속 그리드 재질이 차단성능에 미치는 영향 (An Influence of Material of Metal Grid for Interrupting Property)

  • 김길수;윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.101-101
    • /
    • 2010
  • Power distribution system requires the transformer with higher capacity than ever, but this ever, but this may be the cause of the increasing of short circuit current in contrast to conventional one when short-circuit accident is occurred. Therefore molded case circuit breaker improved in aspects of interrupting capacity of short circuit current in this system is needed. The arrangement and quality of the material of grids in arc quenching room are also designed optimally by the analysis of arc driving forces.

  • PDF

FEM을 이용한 몰드변압기의 예방진단에 관한 연구

  • 청영기;정종욱;최명준;김재철;박일한;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.70-73
    • /
    • 1997
  • This paper describes the technique for detecting failure symptom of mold transformer. This study uses the vibration signal analysis method and FEM as the technique. A loading back method is constructed for experiment, accelation sensors are adhered for measurement of vibration signal. Vibration signal measured by this method is analyzed into variation trend of measurement variables by control of control variables. Magnetic field distribution of molded winding is also acquired by FEM considering the design specfication and the characteristics of insulation material, in conclusion, he relation of results between vibration signal and FEM is studied by these methods.

  • PDF

30kV 절연성능을 갖는 고절연 DC-DC 컨버터에 관한 연구 (A study and implementation of a 30kV highly isolated DC-DC converter)

  • 김정우;부한영;조영훈;김호성;김주용
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.355-356
    • /
    • 2017
  • In this paper, a highly isolated DC-DC converter is designed as a power supply, and an insulator-molded transformer is used to achieve high insulation performance. Finally, the insulation performance of the power supply was verified by experimental results.

  • PDF

25.8 kV용 PT에서 발생하는 부분방전 저감에 관한 연구 (A study on the reduction of PD generated in the PT for 25.8 kV)

  • 송재주;이중근;김성홍;서용균;나도간;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.631-635
    • /
    • 2000
  • Recently, the epoxy molded type PT for indoor and applied 25.8kV was often distroyed by degradation of insulation that effected many electric stress and defect of manufactured goods. therefore In this work, We can present a method of solution in the process of produce the PT through analysis of experiments. In order to reduce the PD (Partial Discharge) which was occurred at the insulation material of epoxy resin, we has many tried to remove faults In the process of the products,

  • PDF

산화마그네슘 첨가에 따른 나노컴퍼지트의 수명평가 (Life Evaluation of Nano-Composites According to the Addition of MgO)

  • 신종열;정인범;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.390-395
    • /
    • 2015
  • Molded insulation materials are widely used from large electric power transformer apparatus to small electrical machinery and apparatus. In this study, by adding MgO with the average particle of several tens nm and the excellent thermal conductivity into molding material, we improved the problem of insulation breakdown strength decrease according to rising temperature in overload or in bad environmental condition. We confirmed the life evaluation by using the insulation breakdown and inverse involution to investigate the electrical characteristics of nano-composites materials. By using a scanning electron microscope, it is confirmed that MgO power with the average particle size of several tens nm is distributed and the filler particles is uniformly distributed in the cross section of specimens. And it is confirmed that the insulation breakdown strength of Virgin specimens is rapidly decreased at the high temperature area. But it is confirmed that the insulation breakdown strength of specimens added MgO slow decreased by thermal properties in the high temperature area improved by the contribution of the heat radiation of MgO and the suppression of tree. The results of life prediction using inverse involution, it is confirmed that the life of nano-composites is improved by contribution of MgO according to the predicted insulation breakdown strength after 10 years of specimens added 5.0 wt% of MgO is increased about 2.9 times at RT, and 4.9 times at $100^{\circ}C$ than Virgin specimen, respectively.