• Title/Summary/Keyword: Moisture-permeability

Search Result 242, Processing Time 0.022 seconds

Study on Ultra Porous Aerogel/fiber Composite for Shoe Insole (초다공성 에어로젤 함유 섬유상 복합체를 이용한 신발 안창소재에 관한 연구)

  • Oh, Kyung-Wha;Park, Soon-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.5
    • /
    • pp.701-710
    • /
    • 2009
  • This study was conducted to develop excellent insole with good thermal insulation using new materials. We investigated that aerogel/fiber composite can be used as padding materials of shoes by comparing surface shape, moisture regain, water vapor permeability, thermal insulation and compression rate of insole materials tried with nonwoven fabric padding materials and insole sold in market. The results are as follows. Surface shapes were shown that the most appropriate material for sealing aerogel/fiber composite was high density fabric as per size of particle of aerogel. Moisture regain of aerogel/fabric composite was better than nonwoven fabric padding samples. However, when compared to insole sold in market, its moisture regain was worse than those of insole merchandises. Water vapor permeability was higher in material padded with nonwoven fabric than materials padded with aerogel/fiber composite in all three kinds of sealing fabrics. Thermal conductivity of aerogel/fabric composite was lower than nonwoven fabric material regardless of sealing fabrics. Thermal insulation of aerogel/fiber composite was higher than padding material of nonwoven fabric regardless of sealing fabrics. Compression rate of nonwoven (SP1) was higher than that of aerogel/fiber composite (SP2). Compressive elastic recovery rate of SP1 was also higher than that of SP2, which its compression rate and compressive elastic recovery rate were both poor. As the above result, ultra porous aerogel/fiber composite were proved to be material of good thermal insulation with lower thermal conductivity and also compression rate was proved to be low. Therefore, we can say that aerogel/fiber composite have high possibility to be used as insole materials for cold winter shoes requiring good thermal insulation protection.

Permeability Effect of Decomposed Granite Soil under the Influence of Crushability and Compaction Energy (화강풍화토(花崗風化土)의 파쇄(破碎) 및 다짐에너지가 투수성(透水性)에 미치는 영향(影響))

  • Lee, Hyoung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.107-116
    • /
    • 1983
  • This paper is concerned with the permeability through a decomposed granite soil layer which is influnced by change of grain sizes and crushed soils made by varied compaction energy. The change in the content of crushed soils can be described in terms of the ratio of surface area ($S_w{^{\prime}}/S_w $). The experiments were carried out to obtain the relationships of the coefficient of permeability(K) versus the optimum moisture content($w_{opt}$) by the variable head permeability test with the samples that were preapared by compaction test. The results are found as follows; (1) By the change in compaction energy, the crush ratio increased whereas the void ratio decreased with a larger maximum dry density running in parallel with the zero air void curve. (2) The ratio of surface area was $0.33(P)^{0.96}$ in $S_w{^{\prime}}/S_w $ with no relation to the compaction energy. (3) The grain size which produced the largest crush of soil particles ranged from 0.5 to 1 millimetre (4) The relationship of K versus $e^3$/1+e appeared as a straight line on the full-log-scale paper under the optimum moisture state. (5) As the compaction energy was larger, the passing percentage of #200-sieve grains increased linearly. The increment in the surface area ratio was deemed to have been caused by the decreased in the permeability.

  • PDF

Heat Transfer and Sterilization Characteristics of an ERV Element Made of Hwang-to Paper (황토지로 제작된 전열교환소자의 전열특성 및 항균특성에 관한 연구)

  • Cho, Min-Chul;Oh, Sai-Kee;Ahn, Young-Chull
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.50-56
    • /
    • 2017
  • To increase the enthalpy exchange efficiency of ERV elements, the moisture exchange character must be improved. The moisture exchange efficiency depends on material characteristics. The material used for ERV is Hwang-to paper based on Han-ji which is Korean traditional paper. The paper has excellent performance in moisture exchange and heat transfer compared with polymer and other papers. To have an anti bacteria performance and to improve moisture exchange performance of Han-ji, Hwang-to is added to the Han-ji. The enthalpy exchange efficiency of the Hwang-to paper shows 5% greater than that of the conventional paper. In case of Escherichia Coli, the reduction rate of bacteria is 96.6% and in case of Pseudomonas, the reduction rate of bacteria is 97.5%. The ERV element made of Hwang-to paper has a great possibility as an ERV element.

Analysis about Fill Deposit Poor Drainage through Permeability Test and Groundwater Monitoring (투수시험과 지하수 모니터링을 통한 매립층의 배수불량 원인 분석)

  • Jung, Hee-Suk;Lee, Kang-Il;Kim, Joon-Seok
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.165-173
    • /
    • 2018
  • Purpose: The area such as historic sites where distributed in the hills surrounded by the mountains in the past, if heavy rains occur, soil that distributed in the substructure of a sedimentary layer's permeability decreases therefore, water do not smoothly drainage and increases surface structures' moisture content. Therefore, many phenomena occur such as the muddy ground. This experiment tried to figure out the cause of poor drainage, predicting poor drainage system when rainfall occur. So not only the base of cultural properties distributed in the historic site, but also have big influences on the upper structure. Method: We are going to propose an improvement plan through the various sites exploration and the field permeability test. In addition, analyze interrelationship to figure out the cause of the poor drainage through monitoring under ground water. Conclusion: As the result of the experiment, the cause of the poor drainage system formed on shallow depth of ground level inside of a land. We can see that soil of surface and fill deposit permeability was in poor condition. Therefore, it was in very inappropriate hydrogeological condition when surface water permeate into the underground when rainfall occurs.

Studies on the Oxygen Permeability and It's Proofness of the Various Commercial Polymer Films (상업용 고분자 필름의 산소투과도 및 산소투과 방지도에 관한 연구)

  • Suh, Hwan-Kyu;Kim, Joon-Soo;Lee, Jung-Keun
    • Elastomers and Composites
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 1980
  • The oxygen permeability and it's proofness of te various commercial polymer films have been investigated at the constant pressure and temperature. Oxygen proofness, the reciprocals of the oxygen permeability for the various samples, were determined by means of a coulometric oxygen permeability tester. The testing of sample films was performed at constant temperature $(23{\pm}1^{\circ}C)$ under 1 atm. for 24 hours. The order of the relative proofness observed are as follows; oriented Nylon (O. Nylon)> oriented Polyester (O. PET)>nonoriented Nylon (N. Nylon)>nonoriented Polyester (N.PET)> rigid Polyvinyl chloride (Rigid PVC)>semirigid Polyvinyl chloride (Semirigid PVC)> oriented Polypropylene (O. PP)>plasticized Polyvinyl chloride (P. PVC)> casted Polypropylene (C. PP)> low density Polyethylene (LDPE)>high density Polyethylene (HDPE, Inflation)> high density-polyethylene (HDPE, T-die) The oxygen proofness of the films was increased with the polarity cf polymer, the film thickness and mechanical orientation and decreased with the addition of plasticizer in PVC. For the use of wrapping materials, one film with the polar property in the main chain of the polymer molecule and the others with nonpolar property in it are laminated for the protection from oxygen and moisture.

  • PDF

The Geotechnical Properties of Municipal Solid Waste Incinerator Fly Ash and Cement Stabilization (도시고형폐기물 소각 비산재의 지반공학적 특성 및 시멘트 안정화에 관한 연구)

  • 조진우;김지용;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.528-535
    • /
    • 2000
  • Solid waste incinerator is expected to become widely used in Korea. The incineration of solid waste produces large quantities of bottom and fly ash, which has been disposed of primary by landfilling. However, as landfills become undesirable other disposal method are being sought. In this study, an experimental research is conducted to determine the geotechnical properties of municipal solid waste incinerator fly ash(MSWIF) in order to evaluate the feasibility of using the material for geotechnical applications. Basic pysicochemical characteristics, moisture-density relationship, strength, permeability, and leaching characteristics are examined. The results of MSWIF are compared to other MSWIF and coal fly ash which are used as construction material. In addition, the effectiveness of cement stabilization is investigated using various mix ratios. The result of stabilized mixes are compared to the unstabilized material. Cement stabilization is found to be very effective in reducing permeability, increasing strength, and immobilizing heavy metals. This results indicate that MSWIF with cement stabilization may be used effectively for geotechnical application.

  • PDF

Application Properties of Ultra Light Weight Silica Aerogel to Polyurethane Membrane (극초경량 실리카 에어로겔의 폴리우레탄 멤브레인 적용 특성)

  • Min, Munhong;Jeong, Cheonhee;Yoon, Seokhan;Yang, Junghan;Kim, Taekyeong
    • Textile Coloration and Finishing
    • /
    • v.25 no.4
    • /
    • pp.279-286
    • /
    • 2013
  • Application properties of ultra light weight silica aerogel toward polyurethane membranes were investigated. From the results of pre-milling process of the silica aerogel, the solvent for dispersion of the aerogel was determined for methyl ethyl ketone and its content in the solvent was determined by 30%. Using this aerogel dispersion, the polyurethane membranes were prepared according to the mixing amount of silica aerogel and various properties of the membranes were investigated. As results, the optimum mixing amount of silica aerogel inside polyurethane membranes was decided at 11%, because the improvement of light weight property, air permeability, and moisture vapor permeability were improved upto 11% of silica aerogel content, maintaining the water penetration resistance almost unchanged.

The Changes in Properties of Dress Shirts by Repeated Washing and Drying (II) (반복세탁 및 건조방법이 드레스셔츠의 물성에 미치는 영향(II))

  • Lee, Song-Ja;Sung, Su-Kwang;Kwon, Hyun-Sun
    • Fashion & Textile Research Journal
    • /
    • v.1 no.3
    • /
    • pp.259-263
    • /
    • 1999
  • This study was carried out to investigate the changes of thermal properties such as warmth retaining and contact warm/cool feeling of commercial dress shirts by repeated washing and drying by sun and dryer. Three kinds of fabrics such as cotton 100%, cotton/polyester 80/20% and polyester 100% were repeatedly washed and dried, and then used as specimen. Thermo Labo II type was employed to measure the thermal properties. At the same time, structural properties such as thickness, weight, bulk density, porosity, moisture vapor permeability and air permeability were analysed.

  • PDF

The estimation on the insulation performance of thermal insulation materials according to water vapor permeance (투습성에 따른 단열재의 단열성능평가 및 고찰)

  • Kim, Seok-Hyun;Park, Jong-Il;Lee, Min-Woo;Hong, Jin-Kwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1012-1018
    • /
    • 2006
  • In this study, the insulation performance of thermal insulation materials such as glass wool, polyetylene and flexible lastomeric foam according to water vapor permeance was estimated by using experimental correlation equation. The results showed the conductivity increment of flexible lastomeric foam which has very low-permeability (${\le}0.15[ng/{\cdot}s{\cdot}Pa]\;or\;{\mu}{\ge}1,000$) is about 50% lower than that of glass wool with the lapse of ten years. The conclusion is that moisture inevitably accumulated in permeable Insulations reduces insulation performance and also accelerates surface condensation in the case of cold water system.

  • PDF

Finite element analysis of concrete cracking at early age

  • Aurich, Mauren;Filho, Americo Campos;Bittencourt, Tulio Nogueira;Shah, Surendra P.
    • Structural Engineering and Mechanics
    • /
    • v.37 no.5
    • /
    • pp.459-473
    • /
    • 2011
  • The study of the early age concrete properties is becoming more important, as the thermal effects and the shrinkage, even in the first hours, could generate cracks, increasing the permeability of the structure and being able to induce problems of durability and functionality in the same ones. The detailed study of the stresses development during the construction process can be decisive to keep low the cracking levels. In this work a computational model, based on the finite element method, was implemented to simulate the early age concrete behavior and, specially, the evaluation of the cracking risk. The finite element analysis encloses the computational modeling of the following phenomena: chemical, thermal, moisture diffusion and mechanical which occur at the first days after the concrete cast. The developed software results were compared with experimental values found in the literature, demonstrating an excellent approach for all the implemented analysis.