• Title/Summary/Keyword: Moisture , Sensor

Search Result 188, Processing Time 0.023 seconds

Humidity Dependence Removal Technology in Oxide Semiconductor Gas Sensors (산화물 반도체 가스 센서의 습도 의존성 제거 기술)

  • Jiho Park;Ji-Wook Yoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.4
    • /
    • pp.347-357
    • /
    • 2024
  • Oxide semiconductor gas sensors are widely used for detecting toxic, explosive, and flammable gases due to their simple structure, cost-effectiveness, and potential integration into compact devices. However, their reliable gas detection is hindered by a longstanding issue known as humidity dependence, wherein the sensor resistance and gas response change significantly in the presence of moisture. This problem has persisted since the inception of oxide semiconductor gas sensors in the 1960s. This paper explores the root causes of humidity dependence in oxide semiconductor gas sensors and presents strategies to address this challenge. Mitigation strategies include functionalizing the gas-sensing material with noble metal/transition metal oxides and rare-earth/rare-earth oxides, as well as implementing a moisture barrier layer to prevent moisture diffusion into the gas-sensing film. Developing oxide semiconductor gas sensors immune to humidity dependence is expected to yield substantial socioeconomic benefits by enabling medical diagnosis, food quality assessment, environmental monitoring, and sensor network establishment.

The moisture measurement of sintering material by the NIR simulator (근적외선 분광법을 이용한 simulator를 통한 소결원료 수분측정)

  • 이진우;정재인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1273-1275
    • /
    • 1996
  • Moisture measurements of s intering materials were performed using the simulator which can simulate various conditions taking place at the belt-conveyor of sintering process. The moisture sensor used in this experiment is NIR moisture meter(JE-330, KETT Electric Lab.). Using the simulator, we measured the moisture contents of sintering materials at different conditions. We found that the moisture content decreased as the rotation speed increased and the size of the sintering materials became smaller.

  • PDF

NON-CONTACT SENSORS FOR DETECTING DISTANCE FROM THE FIELD SURFACE

  • Lee, Jeyong-;Minoru-Yamazaki;Akira-oida;Hiroshi-Nakashima;Hiroshi-Shimizu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.373-382
    • /
    • 1993
  • A non-contact sensor for detecting distance from field surface to a predetermined location of a tractor will be useful to control precise height of implements such as tillage machinery, mowers etc.. An optical and an ultrasonic sensors were designed and fabricated . The indoor and outdoor experiments were conducted to obtain the static and dynamic characteristics of the two sensors at several moisture levels of four soils and on the soil surface with a designed shape. The results revealed that the optical sensor is unsuitable for soils with high moisture content but showed better detecting accuracy on the irregularity of soil surface.

  • PDF

An Experimental Study on the Evaluation of Unit-Water Content in Mortar Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 모르타르의 단위수량 평가에 관한 실험적 연구)

  • Cho, Yang-Je;Yu, Seung-Hwan;Yang, Hyun-Min;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.17-18
    • /
    • 2021
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구)

  • Cho, Yang-Je;Kim, Min-Seo;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

An Experimental Study on the Evaluation of Concrete Unit-Water Content Using High Frequency Moisture Sensor (FDR) (고주파수분센서(FDR)를 활용한 콘크리트 단위수량 평가에 관한 실험적 연구)

  • Lee, Seung-Yeop;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.59-60
    • /
    • 2021
  • The unit-water content has a major problem in concrete structures which leads to micro cracks on the concrete during drying time. Thus, the compressive strength and durability of the concrete structures are significantly reduced. Several techniques have been developed to measure the unit-water content in concrete structures such as heating drying, unit volume mass, and capacitance measurements. However, these techniques have problems in during measurement such as longer time, expensive and difficult in analysis of data. Frequency Domain Reflectivity (FDR) is one of the sensors which used to measure the water content. This method has several advantages including easy to measure, inexpensive, and capable of measuring moisture in real time. In this study, an attempt has been made to evaluate the unit-water content in concrete using the FDR sensor and interpret the data with deep learning method.

  • PDF

Experimental Study on Temperature-Moisture Combined Measurement System for Slope Failure Monitoring (사면붕괴 모니터링에 사용되는 온도-함수비 복합계측시스템 개발에 관한 실험적 연구)

  • Nam, Jin-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • Recently, the event of slope failure has been occurring frequently due to rapid climate changes and broad development of infrastructures, and the research for establishment of monitoring and prevention system has been an attentive issue. The major influence factors of slope failure mechanism can be considered moisture and temperature in soil, and the slope failure can be monitored and predicted through the trend of moisture-temperature change. Therefore, the combined sensing technology for the continuous measurement of moisture-temperature with different soil depths is needed for the slope monitoring system. The various independent sensors for each item (i.e. temperature and moisture respectively) have been developed, however, the research for development of combined sensing system has been hardly carried out. In this study, the high-fidelity sensor combing temperature-moisture measurement by using the minimized current consuming temperature circuit and the microwave emission moisture sensor is developed and applied on the slope failure monitoring system. The feasibility of developed monitoring system is verified by various experimental approaches such as standard performance test, mockup test and long-term field test. As a result, the developed temperature-moisture combined measurement system is verified to be measuring and monitoring the temperature and moisture in soil accurately.

Calibrating Capacitance Sensor for Determining Water Content of Volcanic-Ash Soils (화산회토양의 수분함량측정을 위한 Capacitance Soil Moisture Sensor의 Calibration)

  • Moon, Kyung-Hwan;Joa, Jae-Ho;Choi, Kyung-San;Seo, Hyoeng-Ho;Lim, Han-Cheol;Hyun, Hae-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.331-336
    • /
    • 2011
  • Capacitance soil moisture sensor is extensively used by soil research and irrigation management with its convenience and accuracy. This experiment was conducted to evaluate the acceptability of capacitance soil moisture sensor, named EnviroSCAN made by Sentek Ltd., in Jeju Island where volcanic ash soils are widely distributed, and to calibrate it to various soils with different amount of soil organic matter. For sensor calibration equation of volcanic ash soils, a logarithm function is better than a typical power function of non-volcanic ash soils. So there are possibilities of under evaluated in soil water contents in very wet and very dry conditions by using typical power function with volcanic ash soil areas. We suggested practical coefficients of typical calibration equation for using capacitance sensor in volcanic ash soils, also suggested equations for estimation of them with soil organic matter contents. The measurement of soil water content with a capacitance sensor can be affected by some soil characteristics such as porosity, soil organic matter content, EC, etc. So those factors should be controlled for improving the accuracy of measurement.

A Study on Oil's Contamination Detection System using Optical Fiber Sensor (광섬유 센서를 이용한 오일 오염도 검사시스템 연구)

  • Song, Doo-Sang;Hong, Jun-Hee;Ryu, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.4
    • /
    • pp.541-546
    • /
    • 2012
  • This study investigates the detection system of oil pollution level using single optical fiber sensor. This study focus on sensing of oil pollution by moisture and iron powder which are representatives of oil pollution factor. In addition, It is placed that the water and iron powder as an oil pollution factor in the oil tank which is the oil circulation in. The oil pollution detection system was measured by the changing of intensity of light and sensing gap. The result of this experimentation not only confirmed the contamination by moisture volume in the oil tank from the section 190ppm to 540ppm, but also monitored the contamination by iron volume from the section 1200ppm to 3500ppm. This study confirmed effectiveness of this detection system using optical fiber sensor. There is expectations of measuring another section by various optical fiber sensor.

A Study on Factors Influencing P-wave Velocity of Concrete (콘크리트의 P파 속도에 영향을 주는 인자에 관한 연구)

  • 이광명;이회근;김동수;김지상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.725-730
    • /
    • 1998
  • Recently, non-destructive tests are getting popular in evaluating concrete properties without braking specimens. Among several NDT methods, P-wave velocity measurement technique has been widely used to evaluate the stiffness and strength of concrete. The purpose of this study is to investigate factors influencing P-wave velocity measured by impact-resonant method and ultrasonic pulse velocity method, such as moisture content of concrete, existence and size of coarse aggregates, sensor and sampling rate. Test results show that rod-wave velocity measured by impact-resonant method and ultrasonic pulse velocity are significantly affected by the moisture content of concrete, i.e., the lower moisture content, the lower velocity. Moisture content influences rod-wave velocity stronger than ultrasonic pulse velocity. Rod-wave velocity is faster in concrete than in mortar and is also faster in concrete containing small size aggregates. Sensor and sampling rate have little influence on velocity.

  • PDF