• Title/Summary/Keyword: Moist Air

Search Result 113, Processing Time 0.02 seconds

The Study of Supersonic Flow with Condensation Along a Wavy Wall in a Channel (波形壁 流路내에서 凝縮이 수반되는 超音速유동에 대한 硏究)

  • 권순범;김병지;김흥균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.424-431
    • /
    • 1994
  • The characteristics of supersonic flow with condensation along a wavy wall of a small Smplitude in a channel is investigated experimentally and numerically. In the present study for the case of supersonic moist air flow, the dependency of location of reflection of oblique shock wave generated by the wavy wall, and the distributions of flow properties in the flow field, on the stagnation relative humidity and temperature is clarified by the plots of streamline, iso-Mach number and iso-flow properties of numerical result and the schlieren photographs of experiment. And. experimental and numerical results are in good agreement.

A change of local meteorological environment according to dam construction of Nakdong-River -II. Estimation using numerical model- (낙동강 수계 중의 댐 건설에 의한 주변의 국지기상환경 변화 -II. 수치모델을 이용한 추정-)

  • 전병일;이영미
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.281-288
    • /
    • 2002
  • This study was carried out for reading the change of local meteorological environment according to dam construction of Nakdong-river using numerical model. The study used PSU/NCAR Mesoscale Model version5(MM5) for inquiring effect of formation of artificial lake after dam construction. The colleague simulated temperature mixing ratio, latent heat flux and sensible heat flux in two cause of existing lake and not. Temperature and mixing ratio in southwest of Andong lake increased because of the air that was warm and moist above the lake moved to southwest due to the northeasterly wind. In the case of existing lake around Andong, latent heat flux increased much in the daytime after sunrise. However, sensible heat flux decreased but it didn't change distinctly in southwest of Andong like the other values.

An Experimental Study on Energy Losses in Steam Turbine Cascade Flow (증기터빈 익렬유동의 에너지손실에 관한 실험적 연구)

  • ;;Ahn, Hyung-Joon;Lee, Kwon-Hee
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.11
    • /
    • pp.3022-3030
    • /
    • 1995
  • The irreversibility of condensation process in the supersonic flow of steam turbine cascade causes the entropy to increase and the total pressure loss to be generated. In the present study, in order to investigate the moist air flow in two dimensional steam turbine cascade made as the configuration of the last stage tip section of the actual steam turbine moving blade, the static and total pressures along suction side of the blade are measured by pressure taps and Pitot tube. The flow field is visualized by a Schlieren system. The effects of stagnation temperature and the degree of supersaturation on energy loss and entropy change in the flow are clearly identified.

On the Regional Background Levels of $CH_4$ Observed Peninsula in Korea during 1990~1992 (한국의 태안반도에서 관측된 $CH_4$의 지역적 배경농도에 관한 연구 -1990~1992년 자료를 중심으로-)

  • 정용승;이근준
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.33-48
    • /
    • 1992
  • Since November 1990, the observations of methane (CH4) level have been carried out at Tae-ahn Peninsula (TAP) in Korea. Analysis on atmospheric data obtained in the period from November 1990 to August 1992 is carried out and the results are included in this study. We 임ole that CIL does not have a clear seasonal cycle with a minor maximum in August- september and with a minimum in June-July. The variations in monthly average level are much larger with 1765.01∼ 1857.21 pub (amplitude 92.20 ppb). The occurrence of a minimum in June-July is due to the inflow of the North Pacific air, an increase of OH radical and due to a decrease in CH4 emission from rice paddy. A maximum in August and September appears to result from an increase in organic materials in agriculture (rice paddy) and forests, inputs of local sources due to weak airflows, stagnation of the warm and moist air and from a decrease in OH radical.'rho present analysis indicates that according to CH4 data from Mongolia and from several sites in North Pacific TAP is influenced as much as 31 pub in average from the inputs of Chinese omission. When the atmospheric CH4 of TAP is compared with data observed at Korea National University of Education (KNU), the values of KNU are higher (127 ppb) than those of TAP. It is clear that air samples taken at KNU are influenced strongly by local sources in central Korea than those at TAP. According to analysis of trajectories and airflows, we find that there are 4 types in classification. Firstly, when an air flow is originated mainly in China values of CH4 gas are in medium ranges. Secondly, when an airflow is from both local (Korea) and China we find higher values. Thirdly, with an airflow from both local (Korea) and Japan origins medium values are recorded. Fourths)r, when an airflow of maritime origin arrives low values of atmospheric CH4 are observed at TAP.

  • PDF

Arabidopsis thaliana as Bioindicator of Fungal VOCs in Indoor Air

  • Lee, Samantha;Hung, Richard;Yin, Guohua;Klich, Maren A.;Grimm, Casey;Bennett, Joan W.
    • Mycobiology
    • /
    • v.44 no.3
    • /
    • pp.162-170
    • /
    • 2016
  • In this paper, we demonstrate the ability of Arabidopsis thaliana to detect different mixtures of volatile organic compounds (VOCs) emitted by the common indoor fungus, Aspergillus versicolor, and demonstrate the potential usage of the plant as a bioindicator to monitor fungal VOCs in indoor air. We evaluated the volatile production of Aspergillus versicolor strains SRRC 108 (NRRL 3449) and SRRC 2559 (ATCC 32662) grown on nutrient rich fungal medium, and grown under conditions to mimic the substrate encountered in the built environment where fungi would typically grow indoors (moist wallboard and ceiling tiles). Using headspace solid phase microextraction/gas chromatography-mass spectrometry, we analyzed VOC profiles of the two strains. The most abundant compound produced by both strains on all three media was 1-octen-3-ol. Strain SRRC 2559 made several terpenes not detected from strain SRRC 108. Using a split-plate bioassay, we grew Arabidopsis thaliana in a shared atmosphere with VOCs from the two strains of Aspergillus versicolor grown on yeast extract sucrose medium. The VOCs emitted by SRRC 2559 had an adverse impact on seed germination and plant growth. Chemical standards of individual VOCs from the Aspergillus versicolor mixture (2-methyl-1-butanol, 3-methyl-1-butanol, 1-octen-3-ol, limonene, and ${\beta}-farnesene$), and ${\beta}-caryophyllene$ were tested one by one in seed germination and vegetative plant growth assays. The most inhibitory compound to both seed germination and plant growth was 1-octen-3-ol. Our data suggest that Arabidopsis is a useful model for monitoring indoor air quality as it is sensitive to naturally emitted fungal volatile mixtures as well as to chemical standards of individual compounds, and it exhibits relatively quick concentration- and duration-dependent responses.

EFFECT OF WETNESS ON THE ENAMEL BONDING (법랑질 접착에 대한 습윤 효과)

  • Ko, Keun-Ho;Cho, Young-Gon;Jin, Cheul-Hee;Yoo, Sang-Hoon;Kim, Jong-Uk;Park, Byung-Cheul;Ki, Young-Jae;Choi, Hee-Young;Kim, Jong-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.205-211
    • /
    • 2004
  • This study evaluated the microleakage and interfacial gap between enamel and composite resin under the dry and wet condition of the enamel surface. V shaped class 5 cavities were prepared on the occlusal portion of extracted human molars. Samples were divided into three groups:D group (air dry for 10-15s), BD group (blot dry with moist cotton pellet), and DR group (air dry for 10-15s and rewet with Aqua-Prep F for 20s), Cavities were filled using Aelitefil composite resin after applied One-Step. Microleakage was tested by 2% methylene blue dye solution and the data were statistically analysed by Kruskal-Wallis test and Mann-Whitney test. Also Enamel-resin interface was observed under SEM. Group BD showed statistically lower microleakage than group D (p < 0.05). but there was no statistically significant difference between group BD and DR (p > 0.05). At the enamel-resin interface, group D showed the gap of $2{\;}{\mu}m$ thickness, but group BD and DR showed close adaptation. In conclusion, the use of blot dry and rewetting agent (Aqua-Prep F) resulted in decreased microleakage and improved adhesion between enamel and resin when using One-Step.

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s

On Extratropical Transition of Tropical Cyclone MINDULLE (태풍 민들레의 온대저기압화 과정에 대하여)

  • Kwon, H. Joe;Kim, Ji-Young
    • Atmosphere
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 2005
  • A significant number of tropical cyclones move into the midlatitudes and go through transformation procedure into extratropical cyclones. This process is generally referred to as extratropical transition of the tropical cyclone. In this study, MIDULLE(0407) case is selected. A thorough analysis is made using the GDAPS analysis data and MTM (Moving-nest Typhoon Model) model output. It is found that during the extratropical transition an important dynamics in the environmetal flow field occurs in which colder, drier (warm, moist) air penetrates in the western (eastern) quadrant of MINDULLE's outer circulation, which in turn initiates an asymmetry in the distribution of wind and temperature of the tropical cyclone. Simulated MTM result also reveals similar properties as in GDAPS analysis data. MTM result shows the gradual transition to the asymmetric distribution of wind and thickness as the extratropical transition proceeds. It is also found that the warm core disappears during the extratropical transition stage. Also, vortex tube is shown tilting towards the west during the transition. And the precipitation expands poleward of the center and the maximum precipitation appears to the left of MINDULLE which is consistent to the observations.

Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method (다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석)

  • ;;Yun, In-Chul;Yoo, Je-In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

Thw Characteristic of Supersonic Flow with Condensation along a Wavy Wall of Small Amplitute in Channel (미소진폭 파형벽을 가진 유로내에서 凝縮을 수반하는 超音速 유동의 特性 - 수치해석 결과)

  • 김병지;권순범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1990-1997
    • /
    • 1992
  • The characteristic of supersonic flow with condensation along a wavy wall of small amplitude in channel is investigated through the direct marching method of characteristics. The very complex problem that may appear where the overlapping of the same family characteristics occurs, can be satisfactorily solved by means of the modified method suggested by Zucrow. In the present study for the case of supersonic moist air flow, the dependency of location of formation and reflection of oblique shock wave generated by the wavy wall, and the distributions of flow properties, on the relative humidity and temperature at the entrance of wavy wall is clarified by plots of streamline, ios-Mach umber and ios-flow properties. Also, it is confirmed that the wavy wall plays an important key role in the formation of oblique shock wave, and that the effect of condensation on the flow field appears apparently.