• Title/Summary/Keyword: Moir$\acute{e}$ topography

Search Result 8, Processing Time 0.021 seconds

3-D Reconstruction of Human Face Using the Derivative Moiré Topography

  • Bae, Yoon Jae;Ha, Byeong Wan;Park, Ji An;Cho, Choon Sik
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.500-506
    • /
    • 2014
  • A new 3-D reconstruction algorithm for the human face is proposed using the derivative Moir$\acute{e}$ topography which ensures fast and robust reconstruction even for rough surfaces. The Moir$\acute{e}$ interference fringe pattern is initially obtained through the projection Moir$\acute{e}$ topography based on phase shifting, and then differentiated to provide a full unwrapped phase map for a human face. $2{\pi}$ ambiguity, which has been a chronically unsolved problem with Moir$\acute{e}$ topography, is successfully surmounted by differentiating the Moir$\acute{e}$ fringe patterns both in x- and y-directions when the object is located in the x-y plane. A real human face is used for verifying the proposed derivative Moir$\acute{e}$ topography. A human face of 4 different phase-shifted images taken in the fixed plane is almost fully reconstructed in 3-D format in 0.1 mm lateral resolution.

A Study on 3-D Shape Measurement and Application by using Digital Projection $Moir\acute{e}$ ( I ) (디지털 영사식 무아레를 이용한 3차원 형상 측정과 응용에 관한 연구( I ))

  • Ryu Weon-Jae;Rho Hyung-Min;Lee Dong-Hwan;Kang Young-June
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.88-93
    • /
    • 2005
  • $Moir\acute{e}$ topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by $Moir\acute{e}$ topography has been required, since the method was frequently applied to the engineering and medical fields. The 3-D measurement using projection $Moir\acute{e}$ topography is very attractive because of its high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection $Moir\acute{e}$ topography was tested to measuring object with $2\pi-ambiguity$ problems. The experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi-ambiguity$ problems can be effectively overcome so as to treat large step discontinuities in measured objects.

Two-Wavelength Phase-Shifting Projection $Moir\acute{e}$ Topography for Measurement of Three-Dimensional Profiles with High Step Discontinuities (고단차 불연속 형상의 3차원 측정을 위한 이중파장 위상천이 영사식 무아레)

  • Kim, Seung-Woo;Oh, Jung-Taek;Jung, Moon-Sik;Choi, Yi-Bae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1129-1138
    • /
    • 1999
  • [$Moir\acute{e}$] technique is now being extensively investigated as a fast non-contact means of three-dimensional profile measurement especially for reverse engineering. One problem with $moir\acute{e}$ technique is so called $2\pi$-ambiguity problem that limits the maximum step height difference between two neighboring sampling points to be less than half the equivalent wavelength of $moir\acute{e}$ fringes. In this investigation, a new two-wavelength scheme of projection $moir\acute{e}$ topography is proposed and tested to cope with the $2\pi$-ambiguity problem. Experimental results are discussed to assess the new method in measuring large objects with high step discontinuities.

A Study on the Small Disturbance Measurement of Liquid Film Thickness by $Moir\acute{e}$ Fringe ($Moir\acute{e}$ Fringe에 의한 액막 두께 미소 변위 측정 연구)

  • Jeon, H.S.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.2 no.4
    • /
    • pp.29-35
    • /
    • 1997
  • Liquid film thickness is measured by $moir\acute{e}$ topography which monitored liquid surface. $Moir\acute{e}$ fringe measurement techniques share the inherent simplicity found in optical interferometric techniques have the advantage of use over a greater range of displacement. $Moir\acute{e}$ fringe are the geometric interference patterns observed when two dense line grating are superposed. Light transmitted through a fixed line grating is deviated by the liquid film surface, producing a distored image of the grating. The $moir\acute{e}$ fringe produced by projection of this optically distored grating onto a second stationary grating permit visualization of the liquid surface and measurement of the liquid film thickness. This study measured the small amplitude of liquid film thickness to the $moir\acute{e}$ fringe pattern produced when spherical metal was dropped glycerin put)1 And the measurement of liquid film thickness flowing down an inclined plate are required to calculate the liquid slope in a position.

  • PDF

Clothing-ergonomical Analysis Method for the Basic Torso's Pattern Drafting (토르소 원형설계를 위한 피복인간공학적 분석방법)

  • Kim, Hye-Gyeong;Seo, Chu-Yeon;Seok, Eun-Yeong;Gang, Juk-Hyeong;Kim, Ji-Seon;Kim, Hye-Su;Heo, Ji-Hye
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.109-125
    • /
    • 2000
  • The purpose of this study was to provide basic data for a more functional torso's pattern by analyzing multidimensional anthropometric measurements and the wearing condition. For the functional torso's pattern drafting, the fitness state of basic torso's patterns(4 types) was compared and evaluated from the cross-sectioned overlap maps by $moir{\acute{e}}$ topography. The results were as follows: 1. According to the measurements of four patterns by using the one-dimensional measurement, the amount of ease in girth item for pattern A was the smallest. The ease of clothes was affected by the position of dart, the amount of dart, and the drafting method. 2. As the results of wearing evaluation by $moir{\acute{e}}$ topography method, pattern B had the largest space length for hip part, pattern A, C and D had the largest space length for bust part. Also, in the all measurement items, pattern A had the smallest amount of ease. The space length for bust and waist part of pattern B was smaller than pattern D, but, for abdomen and hip part of pattern B was larger than pattern D. The space length of pattern C was revealed intermediate for all measurement part. 3. The significant difference of space length of each pattern was shown in all parts except bust part(p<.05). The amount of space was affected by the amount of dart, the characteristics of the somatotype, and the drafting method.

  • PDF

Assessment of the Breast-Firmming Effects of a Cosmetic Preparation with Moir$\acute{e}$ Tophography in Combination with 2D and 3D Digital Image Analyses (2D 및 3D 디지털 이미지 분석과 함께 Moir$\acute{e}$ Tophography 분석을 이용한 화장품의 가슴 탄력개선 효과 평가)

  • Seo, Young Kyoung;Yoo, Mi Ae;Ryu, Ja Hyun;Kim, So Jeong;Cho, Seong A;Nam, Gae Won;Cho, Jun-Cheol;Boo, Yong Chool;Koh, Jae-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • Cosmetic products which might augment the breast have attracted an attention and objective methods for the evaluation of such products are in high demand. This study was conducted to establish a method for assessing the breast-firmming effects of cosmetics. This study included a total of 30 healthy Korean females aged 20-50 years. A cosmetic product was applied by massaging it onto the breast twice a day for 8 weeks. Measurement of breast girth with a tape ruler, 2D and 3D digital image analyses, and Moir$\acute{e}$ topographic analysis were performed before and following the treatment. The application of a cosmetic onto the breast significantly increased breast girth at 2, 4 and 8 weeks without a significant change in underbreast girth, implicating the breast might be augmented. The 2D image analysis indicated that the arc length of the breast which represents the surface distance from the nipple to the periphery of the under-breast was significantly increased at 2, 4 and 8 weeks. The height of the breast which represents the perpendicular distance from the nipple to the periphery of the under-breast was also increased significantly at 4 and 8 weeks. The 3D image analysis of body surface also demonstrated a significant increase of breast volume at 2, 4 and 8 weeks. Moir$\acute{e}$ topographic analysis indicated that breast sagging was significantly reduced at 2, 4 and 8 weeks. The results of this study suggest that Moir$\acute{e}$ topography in combination with 2D and 3D digital image analyses may be useful for evaluating the breast-augmenting effects of cosmetics.

A Study on MBES Error Data Removing using Motion Sensor (Motion Sensor를 이용한 MBES 오측자료 제거 연구)

  • Kang, Moon-Kwon;Choi, Yun-Soo;Chang, Min-Chol;Yoon, Ha-Su
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.39-46
    • /
    • 2010
  • Sounding data is the essential source for the safety of ships navigation system, and fundamental to the reasonable usage and maintenance of the ocean as well. As IT tech, positioning equipment such as GPS and INS, echo sounder are developed, recently, the precise submarine topography database bas been built by Multi-Beam Echo Sounder. However, MBES data includes some inevitable error caused by several factor, and some data have errors where the terrain is wobble. The error, which causes the $moir\acute{e}$ pattern error is the main factor hindering the accuracy of MBES data results, and therefore it is necessary to figure out the main cause of the error for the improvement of the accuracy by removing error data. On this research, the main cause of the error data is studied by analyzing motion sensor value of data including the $moir\acute{e}$ pattern error. Thus, as the result of examination, it turns out that the $moir\acute{e}$ pattern error is related to the standard deviation of Roll, and error data values are results of the non-correspondence between Swath data and Roll values caused by the drastic change of Roll values. Accordingly, the error data is removed by comparing between the gradient of Swath data and Roll values. Finally, as the result of removing error data, it is expected to be able to estimate the quality of MBES using the standard deviation of Motion sensor's Roll value, and calculate the additive error factor, which minimize non-corresponding data, and also this research must be contributed to improve the accuracy of sounding for small vessels with lots of motion in the bad circumstance for navigation.

The Effects of 24 weeks passive aquatic rehabilitation exercise on change muscular body type in Women with Osteoarthritis (24주간의 수동적 수중재활운동이 골관절염 여성의 근체형 변화에 미치는 영향)

  • Lee, Hye-Jin
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.349-356
    • /
    • 2017
  • The purpose of this study is to provide guidelines for effective osteoarthritis passive aquatic rehabilitation program and form of exercise prescription through passive aquatic rehabilitation exercise for 24 weeks for women with osteoarthritis. The subjects of this study were the passive aquatic rehabilitation group (CG, n = 10) and the control group (AREG, n = 10) among the subjects who had been diagnosed with osteoarthritis by the K orthopedic surgeon and visited the hospital more than 3 times were selected. The results of this study showed that the change of shoulder height in the group was significantly different in passive aquatic rehabilitation exercise group (p <.001). There were significant differences in passive aquatic rehabilitation exercise group (p <.001) between the groups with inhaled sacpula patterns. Changes in the pelvis patterns inferior pattern of the left and right pelvis patterns in the group were significantly different in passive aquatic rehabilitation exercise group (p <.001).