• Title/Summary/Keyword: Module design

Search Result 4,011, Processing Time 0.03 seconds

A study on the Characteristics of RF switch module on 1${\sim}$3 GHz Band (1${\sim}$3 GHz 대역의 GMS Type Switch Module 특성에 관한 연구)

  • Kim, In-Sung;Song, Jae-Sung;Suh, Young-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1673-1675
    • /
    • 2004
  • The design, modeling and measurement of RF switch module for GSM applications is presented in this paper. RF switch module is constructed using a LTCC multi-layer switching circuit and integrated low pass filter. Insertion and return loss of the low pass filter were designed less than 0.3 dB and better than 12.7 dB at 900 MHz. The RF switch module contained 10 embedded passives and 3 surface mount components integrated on $4.6{\times}4.8{\times}1.2$ mm, 6-layer multi-layer integrated circuit. The insertion loss of switch module was measured at 900 MHz was 11 dB.

  • PDF

A Study on Low Power Force-Directed scheduling for Optimal module selection Architecture Synthesis (최적 모듈 선택 아키텍쳐 합성을 위한 저전력 Force-Directed 스케쥴링에 관한 연구)

  • Choi Ji-young;Kim Hi-seok
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.459-462
    • /
    • 2004
  • In this paper, we present a reducing power consumption of a scheduling for module selection under the time constraint. A a reducing power consumption of a scheduling for module selection under the time constraint execute scheduling and allocation for considering the switching activity. The focus scheduling of this phase adopt Force-Directed Scheduling for low power to existed Force-Directed Scheduling. and it constructs the module selection RT library by in account consideration the mutual correlation of parameters in which the power and the area and delay. when it is, in this paper we formulate the module selection method as a multi-objective optimization and propose a branch and bound approach to explore the large design space of module selection. Therefore, the optimal module selection method proposed to consider power, area, delay parameter at the same time. The comparison experiment analyzed a point of difference between the existed FDS algorithm and a new FDS_RPC algorithm.

  • PDF

Design and Implementation of a Fully Synthesizable Bluetooth Baseband Module Considering IP Reuse

  • Chun, Ik-Jae;Kim, Bo-Gwan
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.1304-1307
    • /
    • 2002
  • In this paper, we describe the structure and the test results of a Bluetooth baseband module we have developed. The module has a distributed buffer, i.e. FIFO, for data stream. Bus interface of the module is designed on the basis of interface of microprocessor widely used and the external interface is designed to consider chips connected directly. Since the module performs as many hardware efficient tasks as possible, processing load of microprocessor is very small. It can also be controlled either by software or by hardware for flexibility. The fully synthesizable baseband module was fabricated in a $0.25\mu\textrm{m}$ CMOS technology occupying $2.79\times2.8{\textrm{mm}^2}$ area. And an FPGA implementation of this module is tested for file and bit-stream transfers between PCs.

  • PDF

The Study of Impact Analysis of TFT-LCD Module (TFT-LCD 모듈의 충격해석에 관한 연구)

  • Lee, Jeoung-Gwen;Choi, Sung-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.5
    • /
    • pp.571-577
    • /
    • 2004
  • The impact behavior of TFT-LCD module is very complicated because the module is assisted with three parts such as back light unit, LCD Panel and top chassis. Especially, the back light unit is constructed with several small and thin parts made by plastics or steels. The design of the back light unit is very important because the recent demand is more lighter, thinner and narrower module. The aim of the present study is the investigation of mechanical characteristics during impact loading. The back light unit must assist TFT-LCD Panel made by glass and guide qualification of handling environment. This paper focus on the dynamic behavior of module and carries out a series of computer simulation using LS-DYNA program. Comparing with test results previously performed, dynamic characteristics of TFT-LCD module are estimated.

Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module (태양광 접속반의 자동 화재 예방 및 진압 시스템 설계)

  • Lee, Kang Won;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.

Preliminary Design of Monitoring and Control Subsystem for GNSS Ground Station (위성항법 지상국 감시제어시스템 예비설계)

  • Jeong, Seong-Kyun;Lee, Jae-Eun;Park, Han-Earl;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.2
    • /
    • pp.227-238
    • /
    • 2008
  • GNSS (Global Navigation Satellite System) Ground Station monitors navigation satellite signal, analyzes navigation result, and uploads correction information to satellite. GNSS Ground Station is considered as a main object for constructing GNSS infra-structure and applied in various fields. ETRI (Electronics and Telecommunications Research Institute) is developing Monitoring and Control subsystem, which is subsystem of GNSS Ground Station. Monitoring and Control subsystem acquires GPS and Galileo satellite signal and provides signal monitoring data to GNSS control center. In this paper, the configurations of GNSS Ground Station and Monitoring and Control subsystem are introduced and the preliminary design of Monitoring and Control subsystem is performed. Monitoring and Control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation solution determination module, independent quality monitoring module, and system operation and maintenance module. The design process uses UML (Unified Modeling Language) method which is a standard for developing software and consists of use-case modeling, domain design, software structure design, and user interface structure design. The preliminary design of Monitoring and Control subsystem enhances operation capability of GNSS Ground Station and is used as basic material for detail design of Monitoring and Control subsystem.

Design of PV-AC Module Flyback Inverter with Decoupling and Energy Storage Functions (디커플링과 에너지 저장 기능을 갖는 PV-AC 모듈형 단상 플라이백 인버터 설계)

  • Ha, Eun-Jung;Ryu, Moo-Young;Noh, Yong-Su;Lee, Taeck-Kie;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.103-104
    • /
    • 2014
  • This paper presents design method of 250[W] grid connected PV-AC module with decoupling and energy storage functions to select optimized passive elements for stable operation. The validity of design of optimized elements is verified by simulation results.

  • PDF

A Multi-Module Three-Loop Controlled Boost Converter for Distributed Power Applications (삼중 루우프 제어방식을 채택한 분산형 전력시스템을 위한 멀티 모듈 승압형 컨버터)

  • Cho, Byung-Cho;Han, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.1041-1045
    • /
    • 1998
  • This paper presents the control design of a three-module boost converter with a two-stage output filter. An advanced three-loop control scheme is employed to the control design in order to obtain good dynamic performance of the converter at the presence of the secondary filter stage. The paper presents the control design, dynamic analysis and performance improvement with the three-loop control.

  • PDF

A Study on the User Toilet Interface for Train Design (철도차량 화장실디자인에 대한 사용자와 제품의 인터페이스)

  • Jin Mi-Ja;Han Suk-Woo;Choe Chel-Hun
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.210-216
    • /
    • 2003
  • This study focuses on the physical environment and human activity of the user of train toilets, on the analysis of factors needed to obtain reasonable toilet design and it also focuses on the understanding of the interface between its user. Moreover it proposes a module of the development process and methods of approaching the User Toilet Interface. The study so presents a design standard under which the concrete data of the characteristics and practicable range and the convergent demands accelerate to the module could be confirmed and criticized.

  • PDF

A Multi-Module Three-Loop Controlled Boost Converter for Distributed Power Applications (삼중 루우프 제어방식을 채택한 분산형 전력시스템을 위한 멀티 모듈 승압형 컨버터)

  • Choi, Byung-Cho;Han, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.693-697
    • /
    • 1998
  • This paper presents the control design of a three-module boost converter with a two-stage output filter. An advanced three-loop control scheme is employed to the control design in order to obtain good dynamic performance of the converter at the presence of the secondary filter stage. The paper presents the control design, dynamic analysis and performance improvement with the three-loop control.

  • PDF