• 제목/요약/키워드: Modulation Method

검색결과 2,145건 처리시간 0.033초

영구자석 직선형 리니어 동기전동기의 오프셋 전압에 의한 공간벡터 PWM의 구현 (Realization of Space Vector PWM using Offset Voltage for PMLSM)

  • 장석명;박지훈;장원범;유대준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1088-1090
    • /
    • 2004
  • This paper presents control pattern of air-cored slotless permanent magnet linear synchronous motor using voltage modulation method which is used space vector voltage modulation and offset voltage modulation.

  • PDF

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

병렬 3레벨 AC/DC 전력변환 시스템의 영상분 순환전류 억제 (Suppression of Circulating Current in Parallel Operation of Three-Level AC/DC Converters)

  • 손영광;지승준;이영기;설승기
    • 전력전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.312-319
    • /
    • 2016
  • Zero-sequence Circulating Current (ZSCC) flows inevitably in parallel converters that share common DC and AC sources. The ZSCC commonly flowing in all converters increases loss and decreases the overall capacity of parallel converters. This paper proposes a simple and effective ZSCC suppression method based on the Space Vector PWM (SVPWM) with the ZSCC controller. The zero-sequence voltage for the proposed SVPWM is calculated on the basis of the grid voltage and not on the phase voltage references. The limit of the linear modulation region of the converters with the proposed method is analyzed and compared with other methods, thereby proving that the limit of the region can be extended with the proposed method. The effectiveness of the proposed method has been verified through the experimental setup comprising four parallel three-level converters. The ZSCC is confirmed to be well suppressed, and the linear modulation region is extended simultaneously with the proposed method. Moreover, the proposed control method does not require any communication between the converters to suppress the ZSCC unlike other conventional methods.

디지털 의료영상에서 Edge method에 의한 Modulation Transfer Function 보정방법과 특이성 (Edge Profile Correction for Modulation Transfer Function on Digital X-ray Imaging System)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.251-257
    • /
    • 2007
  • 디지털 MTF의 정확도를 결정하는 요소로는 정확한 엣지 각도의 결정, 합성 ESF 또는 합성 LSF을 작성을 위한 재 샘플링, 스무징, 커브핏팅 등을 들 수가 있다. 본 실험에서는 Edge를 이용한 MTF커브 핏팅방법을 구현하였고, 슬릿법에 의한 MTF산출결과와 비교하였다. 실험결과 공간주파수 2.0 LP/mm 근방까지의 저주파수영역에서는 엣지법이 높은 수치를 나타내며 2.0 LP/mm 이상의 주파수 영역에서는 MTF값이 역전이 되어 슬릿법이 더욱 높은 값을 나타내었다. 이는 Cunningham의 보고와 완전히 일치한다.

  • PDF

Scheme for Reducing Harmonics in Output Voltage of Modular Multilevel Converters with Offset Voltage Injection

  • Anupom, Devnath;Shin, Dong-Cheol;Lee, Dong-Myung
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1496-1504
    • /
    • 2019
  • This paper proposes a new THD reduction algorithm for modular multilevel converters (MMCs) with offset voltage injection operated in nearest level modulation (NLM). High voltage direct current (HVDC) is actively introduced to the grid connection of offshore wind powers, and this paper deals with a voltage generation technique with an MMC for wind power generation. In the proposed method, third harmonic voltage is added for reducing the THD. The third harmonic voltage is adjusted so that each of the pole voltage magnitudes maintains a constant value with a maximum number of (N+1) levels, where N is the number of sub-modules per arm. By using the proposed method, the THD of the output voltage is mitigated without increasing the switching frequency. In addition, the proposed method has advantageous characteristics such as simple implementation. As a part of this study, this paper compares the THD results of the conventional method and the proposed method with offset voltage injection to reduce the THD. In this paper, simulations have been carried out to verify the effectiveness of the proposed scheme, and the proposed method is implemented by a HILS (Hardware in the Loop Simulation) system. The obtained results show agreement with the simulation results. It is confirmed that the new scheme achieved the maximum level output voltage and improved the THD quality.

고정형(Stationary-gantry) 희소뷰(Sparse-view) CT 보안검색시스템의 공간분해능 평가 (The Evaluation of Spatial Resolution of Stationary-gantry Sparse-view CT Security-screening System)

  • 김영조;최광윤;정춘호;박형규
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.377-384
    • /
    • 2023
  • In this study, the image quality assessment, especially spatial resolution evaluation, for Sparse-view CT reconstructed images was performed. The main goal of the experiment is to evaluate Modulation Transfer Function by using American Standard Method for Measurement of Computed Tomography System Performance(ASTM E1695-95) which uses the edge test object. To compare with the ASTM method, a different method, the radial-type edge profile, to measure MTF using the edge method also performed. Both approaches were tested on the same image acquired by the stationary-gantry sparse-view CT security-screening system using cylindrical test phantom manufactured in accordance with ANSI 42.45. Both of the spatial resolutions at 10% modulation are 0.195, 0.203lp pixel-1, respectively. The method implemented by ASTM E1695-95 showed higher reliability and had a relatively more accurate spatial resolution result than the radial-type edge profile method.

GSM을 위한 우선순위 기반 저복잡도 ML 검출 기법 (A Low-Complexity ML Detector for Generalized Spatial Modulation Based on Priority)

  • 이만희;신수용
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.731-738
    • /
    • 2017
  • 본 논문은 Multiple-input Multiple-output (MIMO) 기법 중에 하나인 Generalized Spatial Modulation (GSM)을 위해 변형된 ML 검출 기법을 제안한다. 기존의 일반적인 ML 검출 기법은 활성 안테나의 수가 증가함에 따라 채널 정보의 크기가 커지기 때문에 높은 복잡도를 가지는 문제가 있다. 이를 해결하기 위하여 송수신 안테나의 수로 고정되는 채널 정보를 이용하고 우선순위를 정하여 그에 따라 활성 안테나 인덱스를 하나씩 검출함으로써 낮은 복잡도를 가지는 기법을 제안한다. 본 논문에서는 모의실험을 통해서 기존의 ML 검출 기법과 제안하는 기법의 복잡도와 Bit Error Rate (BER)을 통해 성능을 평가하고 비교하였다. 복잡도 계산을 위한 모의실험에서 제안하는 검출기법으로 송신 안테나의 수가 10개일 때, 복잡도가 약 45% 감소하는 것을 확인하였다.

DS-CDMA 셀룰라 이동통신 시스템에서 적응변조방식을 이용한 Truncated Type-II Hybrid ARQ 방식과 최대비 합성 다이버시티 기법에 의한 성능 개선 (Improvement Performance of Truncated Type-II Hybrid ARQ Scheme and MRC Diversity Techniques using an Adaptive Modulation in DS -CDMA Cellular Mobile Communication System)

  • 양재훈;김지웅;강희조
    • 한국정보통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.661-667
    • /
    • 2001
  • 본 논문에서는 DS-CDMA 셀룰라 이동통신 시스템에서 고속의 전송데이터를 전송할 시스템을 이루기 위해 적응변조 방식을 적용한 Truncated Type-II Hybrid ARQ 방식을 제안했다. 여기서, 나카가미 페이딩 채널 환경으로 적응변조 방식을 해석하였다. 적응변조 시스템은 나카가미 페이딩 지수에 따라서 변조 레벨과 심볼율을 제어할 수 있다. Eb/No가 높거나 나카가미 페이딩 지수 m이 높을 경우 이 시스템은 높은 변조 레벨과 높은 심볼율을 선택하여 전송 효율을 증가시키는데 목적이 있다. 이와 반대로, $E_b/N_0$가 낮을 경우, 전송 성능 감소를 막기 위해 낮은 변조 레벨과 낮은 심볼율을 선택한다. 변조 방법으로는 QPSK 16QAM, 64QAM, 256QAM을 채용하였다. Truncated Type-II Hybrid ARQ 기법에 의한 적응변조 방식은 실시간 (delay-limited)처리 및 고신뢰도가 요구되는 이동 통신 및 무선 데이터 통신 시스템에 적용이 가능하리라 판단된다.

  • PDF

첨단 지상파항법시스템(eLoran) 시범서비스의 LDC 메시지 변조기법에 따른 수신성능 분석 (Analysis of LDC Message Reception Performance of Korean eLoran Pilot Service according to Modulation Methods)

  • 손표웅;이삭;황태현;서기열
    • 한국항해항만학회지
    • /
    • 제46권6호
    • /
    • pp.525-529
    • /
    • 2022
  • eLoran 시스템에서 보다 높은 정확도로 시각 및 위치 정보를 제공하기 위해 별도의 데이터 채널인 Loran Data Channel (LDC)를 사용한다. LDC 메시지는 기존의 8개의 Loran 펄스 중 항법에 사용하지 않는 3-8번째 펄스의 전송시각을 변조하여 송출하는 Eurofix 방식과 9번째 추가 펄스를 이용해 데이터를 변조하는 9th 펄스 방식으로 변조될 수 있다. 본 논문에서는 eLoran 송신국에서 송출하는 LDC 메시지의 변조방법에 따른 수신 성능을 분석하였다. 인천에 설치하여 시범운영 중인 eLoran 시험 송신국에서 9th 펄스 변조방법과 Eurofix 변조방법으로 동시에 LDC 메시지를 송출할 수 있도록 설정하고, 인천과 평택의 eLoran 보정기준국의 데이터베이스 내 저장된 LDC 메시지를 분석해 변조방법에 따른 LDC 메시지 수신률을 분석하였다. 또한 항로표지 관리선 인성 1호를 이용해 인천항 인근에서 실제 사용자의 LDC 메시지 수신률을 분석하였다. 본 연구결과는 향후 정식 eLoran 서비스 과정에서 공식적인 LDC 방송 메시지를 확정하기 위한 기술자료로 활용될 수 있을 것이다.

여유구동을 지닌 인체의 능동스프링 현상에 대한 해석과 운동주파수 제어방식으로의 적용 (Analysis on Active spring effect in human-body having redundant actuation with application to motion frequency)

  • 이병주
    • 제어로봇시스템학회논문지
    • /
    • 제5권8호
    • /
    • pp.977-989
    • /
    • 1999
  • The purpose of this study is to analyze how the human body having more muscles than its degree-of-freedom modulates an effective stiffness using redundant actuation, and to apply this concept to the design and control of advanced machines which requires adaptable spring. To investigate the adaptable stiffness phenomenon due to redundant actuation in the human body, this paper derives a general stiffness model of the Human body. In particular, for a planar 1 DOF human arm model, a planar 2 DOF human arm model, a spherical 3 DOF shoulder model, a 4 DOF human arm model, and a 7 DOF human arm model, the required nonlinear geometry ad the number of required actuator for successful modulation of the effective stiffness are analyzed along with a load distribution method for modulation of the required stiffness of such systems. Secondly, the concept of motion frequency modulation is introduced to show the usefulness of adaptive stiffness modulation. The motion frequency modulation represents a control of stiffness and / or inertia properties of systems. To show the effectiveness of the proposed algorithm, simulations are performed for 2 DOF anthropomorphic robot.

  • PDF