• Title/Summary/Keyword: Modified glassy carbon electrode

Search Result 73, Processing Time 0.02 seconds

Electrooxidation of DL-norvaline at Glassy Carbon Electrode: Approaching the Modified Electrode for Voltammetric Studies of Hydroquinone and Catechol

  • Kamel, Mahmoud M.
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.23-31
    • /
    • 2014
  • The DL-norvaline was electrochemically oxidized and deposited on the glassy carbon electrode surface using cyclic voltammetry (CV). The modified electrode was examined for electrochemical oxidation of hydroquinone (HQ) and catechol (CC). It exhibited good electrocatalytic ability towards their oxidation and simultaneous determination in a binary mixture using differential pulse voltammetry (DPV). The peak currents were linear to the concentration of HQ and CC, in the range from $5{\mu}M$ to $100{\mu}M$, and $4{\mu}M$ to $140{\mu}M$, respectively. The determination limits(S/N = 3) for HQ and CC were $1{\mu}M$ and $0.8{\mu}M$, respectively. The obtained modified electrode was applied to simultaneous detection of HQ and CC in water sample.

The Determination of Dopamine in the Presence of Ascorbic Acid at the Modified Glassy Carbon Electrode with Phytic Acid and Single-Walled Carbon Nanotubes

  • Bae, Si-Ra;Jeong, Hae-Sang;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2363-2368
    • /
    • 2007
  • A glassy carbon electrode (GCE) modified with phytic acid (PA) and single-walled carbon nanotubes (SWNTs) were investigated by voltammetric methods in buffer solution. The PA-SWNTs/GCE-modified electrode demonstrated substantial enhancements in electrochemical sensitivity and selectivity towards dopamine (DA) in the presence of L-ascorbic acid (AA). The PA-SWNTs films promoted the electron transfer reaction of DA, while the PA film, acting as a negatively charged linker, combined with the positively charged DA to induced DA accumulation in the film at pH under 7.4. However, the PA film restrained the electrochemical response of the negatively charged AA due to the electrostatic repulsion. The anodic peak potentials of DA and AA could be separated by electrochemical techniques, and the interferences from AA were effectively eliminated in the DA determination. Linear calibration plots were obtained in the DA concentration range of 0.1-10 μM and the detection limit of the DA oxidation current was determined to be 0.06 μM at a signal-to-noise ratio of 3. The results indicated that the modified electrode is used to determine DA without interference from AA.

Determination of Cadmium(II) Ion Using the Nafion-Ethylenediamine-Modified Glassy Carbon Electrode (Nafion-Ethylenediamine이 수식된 유리탄소전극에 의한 Cd(II) 이온의 정량)

  • Kim, Jin Ah;Ko, Young Chun;Park, Chan Ju;Park, Byung Ho;Chung, Keun Ho
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.123-130
    • /
    • 2001
  • Determination of cadmium(II) ion with a perfluorinated sulfonated polymer-ethylenediamine(nafion-en) modified glassy carbon electrode was studied. It was based on the chemical reactivity of an immobilized layer(nafion-en) to yield complex $[Cd(en)_2]^{2+}$. The reduction peak potential by differential pulse voltammetry(DPV) was observed at $-0.780({\pm}0.005)V$ vs. As/AgCl. The linear calibration curve was obtained in cadmium(II) ion concentration range $5.0{\times}10^{-7}-2.0{\times}10^{-5}M$, and the detection limit(3s) was $2.20{\times}10^{-7}M$. The detection limit of nafion-en modified glassy carbon electrode has been shown about 14 higher sensitivity than a bare glassy carbon electrode.

  • PDF

Determination of Cobalt(III) Ion Using a Nafion-Ethylenediamine Modified Glassy Carbon Electrode

  • Kim, Seok Jin;Ko, Young Chun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.3
    • /
    • pp.188-192
    • /
    • 2014
  • Determination of cobalt(III) ion with a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode is studied. It is based on the chemical reactivity of an immobilized layer, nafion-en, to yield complex $[Co(en)_3]^{3+}$. The reduction peak potential by differential pulse voltammetry (DPV) is observed at $-0.437{\pm}0.047$ V (vs. Ag/AgCl). The linear calibration curve is obtained in cobalt(III) ion concentration range $1.0{\times}10^{-8}{\sim}1.0{\times}10^{-3}M$ ($5.893{\times}10^{-12}{\sim}5.893{\times}10^{-5}g/mL$).

Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode

  • Xu, Guang-Ri;Xu, Guifang;Xu, Ming-Lu;Zhang, Zhengqing;Tian, Yuan;Choi, Han-Nim;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.415-419
    • /
    • 2012
  • Electrochemical characteristics of nitrite ion were investigated at a poly(methylene blue)-modified glassy carbon electrode by cyclic voltammetry and differential pulse voltammetry. The poly(methylene blue)-modified glassy carbon electrode exhibited enhanced anodic signals for nitrite. The effects of key parameters on the detection of nitrite were evaluated at the modified electrode, such as pH, accumulation time, and scan rate. Under optimum condition, the chemically modified electrode can detect nitrite in the concentration range $2.0{\times}10^{-6}$ to $5.0{\times}10^{-4}$ M with the detection limit of $2.0{\times}10^{-6}$ M and a correlation coefficient of 0.999. The detection of nitrite using the chemically modified electrode was not affected by common ions such as $Na^+$, $K^+$, $Ca^{2+}$, $Cl^-$, $HPO_4^{2-}$ and $H_2PO_4^- $. The modified electrode showed good stability and reproducibility. The practical application of the present method was successfully applied to the determination of nitrite ion in cabbage samples.

Selective Determination of Serotonin on Poly(3,4-ethylenedioxy pyrrole)-single-walled Carbon Nanotube-Modified Glassy Carbon Electrodes

  • Kim, Seul-Ki;Bae, Si-Ra;Ahmed, Mohammad Shamsuddin;You, Jung-Min;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.4
    • /
    • pp.1215-1220
    • /
    • 2011
  • An electrochemically-modified electrode [P(EDOP-SWNTs)/GCE] was prepared by electropolymerization of 3,4-ethylenedioxy pyrrole (EDOP) single-walled carbon nanotubes (SWNTs) on the surface of a glassy carbon electrode (GCE) and characterized by SEM, CV, and DPV. This modified electrode was employed as an electrochemical biosensor for the selective determination of serotonin concentrations at pH 7.4 and exhibited a typical enhanced effect on the current response of serotonin with a lower oxidation overpotential. The linear response was in the range of $1.0{\times}10^{-7}$ to $1.0{\times}10^{-5}$ M, with a correlation coefficient of 0.998 on the anodic current. The lower detection limit was calculated as 5.0 nM. Due to the relatively low currents and difference of potentials in the electrochemical responses of uric acid (UA), ascorbic acid (AA), and dopamine (DA), the modified electrode was a useful and effective sensing device for the selective and sensitive serotonin determination in the presence of UA, AA, and DA.

Electrochemical Determination of 6-Benzylaminopurine (6-BAP) Using a Single-wall Carbon Nanotube-dicetyl Phosphate Film Coated Glassy Carbon Electrode

  • Li, Chunya
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.7
    • /
    • pp.991-994
    • /
    • 2006
  • Herein, insoluble single-walled carbon nanotube (SWNT) was successfully dispersed into water in the presence of a special kind of surfactant-dicetyl phosphate (DCP), subsequently, a SWNT-DCP composite film coated glassy carbon electrode (GCE) was fabricated. The electrochemical behaviors of 6-benzylaminopurine (6-BAP) at the unmodified GCE and SWNT-DCP modified GCE were examined. It is found that the SWNT-DCP modified GCE remarkably enhances the oxidation peak current of 6-BAP, indicating great potential in the determination of trace level of 6-BAP. Finally, a sensitive and simple voltammetric method with a good linear relationship in the range of ${\times}5.0\;\;10^{-8}\sim 2.5\;{\times}\;10^{-6}$ mol/L, was developed for the determination of 6-BAP. The detection limit is as low as $2.0\;{\times}\;10^{-8}$ mol/L for 3-min accumulation. This newly-proposed method was successfully demonstrated with practical samples.

Voltammetric Study of Anionic Surfactant-Modified Glassy Carbon Electrode for Bis(2,2'-Bipyridyl)Copper(II) in 200 mM NaBr

  • Ko, Young Chun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.2
    • /
    • pp.120-123
    • /
    • 2014
  • When a hydrophobic and hydrophilic environments of bis(2,2'-bipyridyl) copper(II) ($Cu(bpy)_2{^{2+}}$) are produced in the presence of anionic surfactant sodium dodecyl sulfate (SDS), cyclic voltammetry is used to investigate the microscopic environments which occurs at the glassy carbon electrode. In order to see the relation between ${\Delta}E_p$ and a critical micelle concentration (CMC), ${\Delta}E_p$ vs. -Log[SDS] for the redox couples are plotted. The concentration at the intersection of two lines is 2.57 mM SDS, and this concentration can be determined as the CMC (relative error: below 0.03%; 2.63 mM SDS by surface tensiometry).