• Title/Summary/Keyword: Modified electrode

Search Result 490, Processing Time 0.028 seconds

A Study on Oxygen Reduction Reaction of PtM Electrocatalysts Synthesized by a Modified Polyol Process (수정된 폴리올 방법을 적용하여 합성한 PtM 촉매들의 산소환원반응성 연구)

  • Yang, Jongwon;Hyun, Kyuwhan;Chu, Cheunho;Kwon, Yongchai
    • Applied Chemistry for Engineering
    • /
    • v.25 no.1
    • /
    • pp.78-83
    • /
    • 2014
  • In this research, we evaluated the performance and characteristics of carbon supported PtM (M = Ni and Y) alloy catalysts (PtM/Cs) synthesized by a modified polyol method. With the PtM/Cs employed as a catalyst for the oxygen reduction reaction (ORR) of cathodes in proton exchange membrane fuel cells (PEMFCs), their catalytic and ORR activities and electrical performance were investigated and compared with those of commercial Pt/C. Their particle sizes, particle distributions and electrochemically active surface areas (EAS) were measured by TEM and cyclic voltammetry (CV), while their ORR activity and electrical performance were explored using linear sweeping voltammetries with rotating disk electrodes and rotating ring-disk electrodes as well as PEMFC single cell tests. TEM and CV measurements show that PtM/Cs have the compatible particle size and EAS with Pt/C. When it comes to ORR activity, PtM/C showed the equivalent or better half-wave potential, kinetic current density, transferred electron number per oxygen molecule and $H_2O_2$ production(%) to or than commerical Pt/C. Based on results gained by the three electrode tests, when the PEMFC single cell tests were carried out, the current density measured at 0.6 V and maximum power density of PEMFC single cell adopting PtM/C catalysts were better than those adopting Pt/C catalyst. It is therefore concluded that PtM/C catalysts synthesized by modified polyol can result in the equivalent or better ORR catalytic capability and PEMFC performance to or than commercial Pt/C catalyst.

Enhanced High-Temperature Performance of LiNi0.6Co0.2Mn0.2O2 Positive Electrode Materials by the Addition of nano-Al2O3 during the Synthetic Process (LiNi0.6Co0.2Mn0.2O2 양극 활물질의 합성공정 중 나노크기 알루미나 추가에 의한 고온수명 개선)

  • Park, Ji Min;Kim, Daeun;Kim, Hae Bin;Bae, Joong Ho;Lee, Ye-Ji;Myoung, Jae In;Hwang, Eunkyoung;Yim, Taeeun;Song, Jun Ho;Yu, Ji-Sang;Ryu, Ji Heon
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.80-86
    • /
    • 2016
  • High Ni content layered oxide materials for the positive electrode in lithium-ion batteries have high specific capacity. However, their poor electrochemical and thermal stability at elevated temperature restrict the practical use. A small amount of $Al_2O_3$ was added to the mixture of transition metal hydroxide and lithium hydroxide. The $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ was simultaneously doped and coated with $Al_2O_3$ during heat-treatment. Electrochemical characteristics of modified $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ were evaluated by the galvanostatic cycling and the LSTA(linear sweep thermmametry) at the constant voltage conditions. The nano-sized $Al_2O_3$ added materials show better cycle performance at elevated temperature than that of micro-sized $Al_2O_3$. As the added amount of nano-$Al_2O_3$ increased, the thermal stability of electrode also enhanced, but the use of 2.5 mol% Al showed the best high temperature performance.

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

AN EXPERIMENTAL STUDY ON THE OSSEOINTEGRATION OF THE TI-6AL-4V BEAD COATING IMPLANTS (Ti-6Al-4V 비드코팅 임프란트 시제품의 골유착에 대한 실험적 연구)

  • Woo, Jin-Oh;Park, Bong-Wook;Byun, June-Ho;Kim, Seung-Eon;Kim, Gyoo-Cheon;Park, Bong-Soo;Kim, Jong-Ryoul
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.1
    • /
    • pp.52-59
    • /
    • 2008
  • The geometric design of an implant surface may play an important role in affecting early osseointegration. It is well known that the porous surfaced implant had much benefits for the osseointegration and the early stability of implant. However, the porous surfaced implant had weakness from the transgingival contamitants, and it resulted in alveolar bone loss. The other problem identified with porous surface implant is the loss of physical properties resulting from the bead sintering process. In this study, we developed the new bead coating implant to overcome the disadvantages of porous surfaced implant. Ti-6Al-4V beads were supplied from STARMET (USA). The beads were prepared by a plasma rotating electrode process (PREP) and had a nearly spherical shape with a diameter of 75-150 ${\mu}m$. Two types of titanium implants were supplied by KJ Meditech (Korea). One is an external hexa system (External type) and the other is an internal system with threads (Internal type). The implants were pasted with beads using polyvinylalcohol solution as a binder, and then sintered at 1250 $^{\circ}C$ for 2 hours in vacuum of $10^{-5}$ torr. The resulting porous structure was 400-500 ${\mu}m$ thick and consisted of three to four bead layers bonded to each other and the implant. The pore size was in the range of 50-150 ${\mu}m$ and the porosity was 30-40 % in volume. The aim of this study was to evaluate the osseointegration of the newly developed dental implant. The experimental implants (n=16) were inserted in the unilateral femur of 4 mongrel dogs. All animals were killed at 8 weeks after implantation, and samples were harvested for hitological examination. All bead coated porous implants were successfully osseointegrated with peripheral bone. The average bone-implant contact ratios were 84.6 % (External type) and 81.5 % (Internal type). In the modified Goldner's trichrome staining, new generated mature bones were observed at the implant interface at 8 weeks after implantation. Although, further studies are required, we could conclude that the newly developed vacuum sintered Ti-6Al-4V bead coating implant was strong enough to resist the implant insertion force, and it was easily osseointegrated with peripheral bone.

Detection of Groundwater Table Changes in Alluvium Using Electrical Resistivity Monitoring Method (전기비저항 모니터링 방법을 이용한 충적층 지하수위 변동 감지)

  • 김형수
    • The Journal of Engineering Geology
    • /
    • v.7 no.2
    • /
    • pp.139-149
    • /
    • 1997
  • Electrical resistivity monitoring methods were adopted to detect groundwater table change in alluvium. Numerical modelling test using finite element method(FEM) and field resisfivity monitoring were conducted in the study. The field monitoring data were acquired in the alluvium deposit site in Jeong-Dong Ri, Geum River where pumping test had been conducted continuously for 20 days to make artificial changes of groundwater table. The unit distance of the electrode array was 4m and 21 fixed electrodes were applied in numerical calculation and field data acquisition. "Modified Wenner" and dipole-dipole array configurations were used in the study. The models used in two-dimensional numerical test were designed on the basis of the simplifving geological model of the alluvium in Jeong Dong Ri, Geum River. Numerical test results show that the apparent resistivity pseudosections were changed in the vicinity of the pootion where groundwater table was changed. Furthermore, there are some apparent resistivity changes in the boundary between aquifer and crystalline basement rock which overlays the aquifer. The field monitoring data also give similar results which were observed in numerical tests. From the numerical test using FEM and field resistivity monitoring observations in alluvium site of Geum River, the electrical monitoring method is proved to be a useful tool for detecting groundwater behavior including groundwater table change. There are some limitations, however, in the application of the resistivity method only because the change of groundwater table does not give enough variations in the apparent resistivity pseudosections to estimate the amount of groundwater table change. For the improved detection of groundwater table changes, it is desirable to combine the resistivity method with other geophysical methods that reveal the underground image such as high-resolution seismic and/or ground penetrating radar surveys.

  • PDF

Sintering of ZrO2-modified 0.96(K0.5Na0.5)NbO3-0.04SrZrO3 Piezoelectric Ceramics in a Reduced Atmosphere (ZrO2 첨가된 0.96(K0.5Na0.5)NbO3-0.04SrZrO3 압전세라믹스의 환원분위기 소결)

  • Kang, Kyung-Min;Cho, Jeong-Ho;Nam, Joong-Hee;Ko, Tae-Gyung;Chun, Myoung-Pyo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.563-567
    • /
    • 2011
  • The most widely used piezoelectric ceramics are lead oxide based ferroelectrics (PZT). However, the toxicity of lead oxide and its high vapor pressure during processing have led to a demand for alternative lead-free piezoelectric materials. We synthesized Lead-free piezoelectric ceramics of $0.96(K_{0.5}Na_{0.5})NbO_3-0.04SrZrO_3+x$ mol% $ZrO_2$ [KNN-SZ+$xZrO_2$; x= 0~0.10] doped with 0.1 wt% $MnO_2$ by a conventional solid state method. We investigated the piezoelectric properties and microstructures of these disk samples sintered in reduced atmosphere in order to evaluate the possibility of the multilayered piezoelectric ceramics having the base metal such as Ni as a internal electrode. All of these KNN-SZ samples sintered in 3%$H_2-97%N_2$ atmosphere at $1,140^{\circ}C$ exhibit pure perovskite structure irrespective of the content of $ZrO_2$. Meanwhile, the sintering denisty and piezoelectric properties such as $K_p$, $Q_m$ and $d_{33}$ of KNN-SZ samples as a function of $ZrO_2$ content show the maxima ($k_p$=28.07%, $Q_m$= 101.34, $d_{33}$= 156 pC/N) at x= 0.04 and it is likely that there is some morphotropic phase boundary(MPB) in this KNN-SZ+$xZrO_2$ composition system. These results indicate that the ceramic composition is a promising candidate material for applications in lead free multilayer piezoelectric ceramics.

Relationship of the use of some fluoride containing dentifrice on the korean market to children's fluoride intake in different age groups (국내 시판 일부 불소함유치약 사용 시 연령별 어린이 불소섭취량)

  • Lee, Kyeong-Hee;Choi, Choong-Ho;Hong, Suk-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.5
    • /
    • pp.881-896
    • /
    • 2012
  • Objectives : The purpose of this study was to examine the amount of daily fluoride intake among children using fluoride-containing dentifrice in an effort to pave the way for the selection of criteria for the development of safe dentifrice for different age groups to make a contribution to children's oral health. Methods : This study was implemented over approximately six months from May to October 2008 by recruiting subjects, asking their consent, conducting a survey, collecting samples and analyzing the collected data. The subjects in this study were preschool residents in Seoul and Gyeonggi province, who were at the western age of 2 to 5. The amount of fluoride withdrawn from their one-time toothbrushing was measured in two different ways. One was by using HMDS-facilitated modified diffusion method and fluoride ion electrode, and the other was by applying ion chromatography without the diffusion procedure. Results : The fluoride intake accounted for $46.5{\pm}19.1$ percent of the amount of fluoride used, and that percentage was statistically significantly different according to age(p<0.01). The one-time fluoride intake from dentifrice per weight(kg) was a mean of $0.009{\pm}0.006mg$. As a result of multiplying this amount by daily toothbrushing frequency, the daily fluoride intake from dentifrice per weight(kg) appeared to be $0.023{\pm}0.016mg$ on average. There was a large difference among the children in that regard, since that ranged from a low of 0.003mg to a high of 0.070mg. And age made a statistically significant difference to that(p<0.01). Conclusions : The above-mentioned findings of the study showed that the children's daily fluoride intake from dentifrice per weight was lower than the recommended daily fluoride intake from diets per weight for young children aged 1 to 12(0.05-0.07mg). However, there was a great disparity among the children in that aspect, and they are likely to take more fluoride from other things as well. Therefore it is required to prepare separate criteria for preschool and school-aged children.

Improving Charge Injection Characteristics and Electrical Performances of Polymer Field-Effect Transistors by Selective Surface Energy Control of Electrode-Contacted Substrate (에폭시 개질 한 다관능 아크릴레이트를 포함하는 충격 저항성이 향상된 불포화폴리에스터 SMC (Sheet Molding Compound) 소재제조 및 그의 물성연구)

  • Jang, Jeong Beom;Kim, Taehee;Kim, Hye Jin;Lee, Wonjoo;Seo, Bongkuk;Kim, Yongsung;Kim, Changyoon;Lim, Choong-Sun
    • Journal of Adhesion and Interface
    • /
    • v.21 no.3
    • /
    • pp.101-106
    • /
    • 2020
  • In this study, epoxy-modified acrylate was synthesized. The synthesized acrylate was added to the composition for sheet molding compound (SMC) in the range of 5 phr to 15 phr. The prepared SMC prepreg was molded at high temperature and pressure to produce a glass fiber reinforced composite. Physical properties such as tensile and impact strength of the composite were measured, respectively. Experimental data show that the composite with 5 phr of synthesized acrylate has 20% improved tensile strength and 12% improved impact strength than that of the reference sample.

Electromyographic studies on the masseter and temporal muscles during exchange of the deciduous teeth (유치 교환기의 교근 및 측두근의 근전도 연구)

  • Lee, Jong-Heun
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.33-44
    • /
    • 1969
  • Electoromyographic studies were performed on the action of the muscles of the temporomandibular joints following exfoliation of the deciduous teeth. The subjects examined, being 50 children. between the age of 6 and 13 years, divided into 5 groups. They were; 1) Deciduous dentition were complete in the first group. 2) Deciduous incisors were missing in either upper or lower jaw in the second group. 3) Deciduous canine and molars were missing in the left side of either upper or lower jaw in the third group. 4) Deciduous canine and molars were missing in the right side of either upper or lower jaw in the fourth group. 5) Permanent dentition completed in the fifth group(except third molars). Electromyogram was recorded with 4 channel polygraph (Grass model VII modified for 7P3). Electrodes which were the cup-typed gold discs, 9 millimeters in the diameter, were located on the anterior, middle and posterior lobes of the temporal muscles, and also on the superficial and deep layers of the masseter muscles. Paired electrodes were held by electrode cream so that they were pressed on the skin surface at right angle, adhesive tape being used to anchor them. The distance of the pair electrodes was about 5 millimeters. The results obtained were as follow: 1) In rest position of mandible; All groups showed slight, electrical activities in the muscles involved, but in the middle lobe of temporal muscle they were slightly higher. 2) In molar occlusion of mandible; High activity-anterior lobe of temporal muscle and superficial layer of masseter muscle. Moderate activity-deep layer of masseter muscle. Low activity-middle and posterior lobes of masseter muscle. There were no differences among the first, the second and the fifth groups. In the third group the muscle activity was weaker than that of the right, and in the fourth group opposite characteristics was revealed. 3) In incisal bite of mandreble; Hight activity-superficial layer of masseter muscle. Modertae activity-deep layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. The first, the third, the fourth and the fifth groups showed no differences but the second group showed less activity than those of others. 4) In protrusion of mandible; High activity-deep layer of masseter muscle Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the fourth and the fifth groups, there were no differences in the activities, but the second group showed less activity than the others. 5) In retrusion of mandible; High activity-deep layer of masseter muscle. Moderate activity-superficial layer of masseter muscle. Low activity-anterior, middle and posterior lobes of temporal muscle. In the first, the third, the fourth and the fifth groups, there were no differences but the second group showed less activity than the others. 6) In lateral excursion of the mandible (either direction); High activity-posterior lobe of temporal muscle. Moderate activity-anterior and middle lobes of temporal muscle. Low activity-superficial and deep layers of masseter muscle. The muscle action potentials were weaker than those of the right side in the third group and vice ver'sa in the fourth group. 7) In chewing movement; Temporal muscle activities were higher than those of masseter, especially in the middle lobe of temporal muscle the activity was highest. Right side muscle activities were higher than those of the left in the third group and, on the contrary, the left side was dominant over the right in the fourth group.

  • PDF