• Title/Summary/Keyword: Modified Sulfur

Search Result 95, Processing Time 0.019 seconds

Monitoring of Particulate Matter and Analysis of Black Carbon and Some Particle Containing Toxic Trace in the City of Yaoundé, Cameroon

  • Tchuente, Siaka Y.F.;Saidou, Saidou;Yakum, N.Y.;Kenmoe, N.X.;Abdourahimi, Abdourahimi
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.120-128
    • /
    • 2013
  • The concentration and composition of particulate matter (PM) in the atmosphere can directly reflect the environmental pollution. The atmospheric pollution in some Cameroonian cities is increasing with the industrial development and urbanization. Air pollution is inherently complex, containing PM of varied size and composition. This PM exists as a dynamic cloud interacting with sunlight and is modified by the meteorology. The reflectometer and the EDXRF spectrometry are applied to determine the concentration of some specific elements at four sites in the city of Yaound$\acute{e}$. The particular aim of the present work is to put in place data base on air pollution in urban area and elaborate regulations on the emissions issued to industrial and vehicle activities. This study provides an overview of the concentration of black carbon and some specific elements in the air, which have impacts on human health. The measurement was done by distinguishing the size of particle. So that, the particle with aerodynamic diameter between $2.5-10{\mu}m$ (so-called coarse particle) and aerodynamic diameter < $2.5{\mu}m$ (so-called fine particle) were considered to obtain more information about levels of the inhalable fraction of the location. The results obtained in four locations of the city of Yaound$\acute{e}$ show that the black carbon concentration is very considerable, the element sulfur is a major pollutant and the concentration of fine particle is very greater. The results obtained of fine and coarse filters range from $5-17{\mu}g/m^3$ and $10-18{\mu}g/m^3$ for the black carbon. S, Cu, Zn, Pb, Cd, As, Se and Hg are the specific findings of this work. The pollutants with a greater concentration are S, Pb, and Zn. These later seem to be non-uniformly, non-regular in some location and high compared to other countries. This work allows us to make a potential relation between pollutants and emission sources. In this framework, some suggestions have been proposed to reduce emissions for an improvement of the air quality in the environment and thus, the one of the city of Yaound$\acute{e}$.

Microbial Structure and Community of RBC Biofilm Removing Nitrate and Phosphorus from Domestic Wastewater

  • Lee, Han-Woong;Choi, Eui-So;Yun, Zu-Whan;Park, Yong-Keun
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.8
    • /
    • pp.1459-1469
    • /
    • 2008
  • Using a rotating biological contactor modified with a sequencing bath reactor system (SBRBC) designed and operated to remove phosphate and nitrogen [58], the microbial community structure of the biofilm from the SBRBC system was characterized based on the extracellular polymeric substance (EPS) constituents, electron microscopy, and molecular techniques. Protein and carbohydrate were identified as the major EPS constituents at three different biofilm thicknesses, where the amount of EPS and bacterial cell number were highest in the initial thickness of 0-100${\mu}m$. However, the percent of carbohydrate in the total amount of EPS decreased by about 11.23%, whereas the percent of protein increased by about 11.15% as the biofilm grew. Thus, an abundant quantity of EPS and cell mass, as well as a specific quality of EPS were apparently needed to attach to the substratum in the first step of the biofilm growth. A FISH analysis revealed that the dominant phylogenetic group was $\beta$- and $\gamma$-Proteobacteria, where a significant subclass of Proteobacteria for removing phosphate and/or nitrate was found within a biofilm thickness of 0-250${\mu}m$. In addition, 16S rDNA clone libraries revealed that Klebsiella sp. and Citrobacter sp. were most dominant within the initial biofilm thickness of 0-250${\mu}m$, whereas sulfur-oxidizing bacteria, such as Beggiatoa sp. and Thiothrix sp., were detected in a biofilm thickness over 250${\mu}m$. The results of the bacterial community structure analysis using molecular techniques agreed with the results of the morphological structure based on scanning electron microscopy. Therefore, the overall results indicated that coliform bacteria participated in the nitrate and phosphorus removal when using the SBRBC system. Moreover, the structure of the biofilm was also found to be related to the EPS constituents, as well as the nitrogen and phosphate removal efficiency. Consequently, since this is the first identification of the bacterial community and structure of the biofilm from an RBC simultaneously removing nitrogen and phosphate from domestic wastewater, and it is hoped that the present results may provide a foundation for understanding nitrate and phosphate removal by an RBC system.

Purification and Some Properties of Glutamine Synthetase lsolated from Chlorobium limicola f. thiosulfatophilum NCIB 8327 (Chlorobium limicola f. thiosulfatophilum NCIB 8327로부터 Glutamine Synthetase의 분리 및 특성분석)

  • Na, Jong-Uk;Kim, Ji-Yoon;Yoon, Hwan;Kang, Sa-Ouk
    • Korean Journal of Microbiology
    • /
    • v.30 no.6
    • /
    • pp.564-569
    • /
    • 1992
  • A green sulfur bacterium, Chlorobium limicola f. thiosulfatophilum NCIB 8327, was grown in modified Pfennig's medium including glu1amate as a nitrogen source. Glutamine synthetase was isolated through a series of ultracentrifugation. DEAE-Sepharose CL-6B ion exchange chromatography. Sephacryl S-300 gel permeation chromatography, and preparative HPLC. The recovery and purification fold of the enzyme were 2% and 46.3. respectively. The isolated enzyme was homogeneous on UV-Visible spectrum and polyacrylamide gel electrophoretogram. The relative molecular mass of the native enzyme was estimated to be 280,000 by gel permeation chromatography. The enzyme consisted of ten subunits with relative similar molecular mass. 30.000. which was estimated by SDS-polyacrylamide gel electrophoresis. The optimal temperature and pH of the enzyme were $30^{\circ}C$ and 7.0. Km values were 27.9 mM for L-glutamine and 0.92 mM for hydroxylamine-HCr. The enzyme activity was inhibited by alanine. glycine. and tryptophan considerably, but was not affected by asparagine, lysine. leucine. and valine.

  • PDF

A Study on Health Status of Workers in Metal Manufacturing Industries (금속제조 산업근로자들의 건강실태 조사)

  • 정경석
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.67-80
    • /
    • 1982
  • In order to evaluate the psychosomatic health status of metal manufacturing industries workers and their working environments, the present study was conducted from March 1, 1981 to the end of September 1981. The data was obtained from the samples of metal manufacturing industries in Kyung-In Area and their 1, 162 employees. In addition, the 803 urban residents including students, office clerks, and general publics were sampled as control groups to compare with factory employees in psychosomatic analysis. The basic tool employed in the present study was the Todai Health Index (THI) which modified CMI and was developed by Tokyo University Research Team of Japan. The results of the present study were summarized as follows: 1. Working environments of the factories 1) The data shows that fabrication shop produced the highest noise level ranging from 91 to 96 dB (A) and iron and steel shop had the lowest noise level ranging from 81 to 86 dB (A). 2) Dust concentration was the highest in iron foundry shop ($3.8 mg/m^3$) and the lowest in fabrication shop ($1.2 mg/m^3$). 3) WBGT above threshold limit values (T.L.V.) was noted in steel shop (38$\circ$C) and iron foundry shop (34$\circ$C) 4) The concentration of Sulfur dioxide ($SO_2$)was 30.5ppm at steel shop and 12.0ppm at iron foundry shop. 5) The concentration of carbon monoxide (CO) was 140.0ppm at steel shop and 110.5ppm at iron foundry shop. 6) The atmospheric lead concentration was $0.49 mg/m^3$ at soldering shop. 2. The responses of psychosomatic complaints were much higher in steel shops group than in other manu-facturing group, except the response of aggressiveness. 3. The responses of psychosomatic complaints were much higher in industrial workers than in urban residents, except the responses of depression and aggressiveness (p < 0.01 ). 4. The psychosomatic symptoms which industrial workers and urban residents complained frequently were nervousness. agressiveness and lie scale in order. 5. The responses of psychosomatic complaints by sex were much higher in female group than in male group, except the response of aggressiveness. 6. The responses of psychosomatic complaints by age were that both the female and male group showed an increasing tendency in the all items, except the response of depression as age was increasing. 7. The responses of psychosomatic complaints by the length of services were that both the female and male group showed a tendency of increasing in physical symptoms as work years increased. 8. The responses of psychosomatic complaints were higher in unmarried group in the score of nervousness, aggressiveness, mental irritability and irregular life.

  • PDF

A study on the intraoral factor related to oral malodor (구취발생에 관여하는 구강내부요인에 관한 연구)

  • Jung, Mi-Ae;Lee, Eun-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.119-131
    • /
    • 2008
  • This study was peformed in order to find out the relationship between the causing factors and the production of each gas 01 oral malodor, to contribute the oral malodor control at dental clinic as well as to establish the effective application of malodor control project for public oral health program 127 patients from 20 to 40 years old who had been visited for preventive dental cares were participated for the study. Such items as caries status, periodontal status, salivary flow, viscosity, pH. Snyder test, plaque deposit and tongue plaque were checked through the oral examination in order to find out the contributing factors Hydrogen sulfide, Methyl mercaptan, Di-methyl sulfide and Ammonia gas components were checked with Oral-Chroma and Attain, the oral malodor check units. Not only the corelation coefficiencies but also the multi-way variance analysis were calculated between each causing factor and each component of oral malodor gases to estimate the contributing factors of the oral malodor. 1. There was no relationship between the caries status and each component pf the oral malodor such as sulfur compound or Ammonia, both in laboratory test and VAS test (pF0.05). It revealed negative relationship between Hydrogen sulfide and FT(rM-0.1904. pE0.05) as well as the VAS and FT (rM-0.210. pE0.05). S0, it was estimated that the less oral malador was recognized when caries state changed to filled state in Hydrogen sulfide laboratory test or VAS test 2. High relationship was showed between salivary flow and Hydrogen sulfide (rM-0.183, pM0.039), Methyl mercaptan(rM-0.234, p-0.008). Dimethyl sulfide(rM-0.234, pM0.008) and Ammonia(-0.361. pM0.001) gas(pE0.05). 3. There was a high relationship between M-PHP(Modified-Patient Hygiene Performance Index) and tong plaque all kinds of sulfide(rM0.249. pM0.005). Ammonia gas component(rM0.232, pM0.009). 4. It was found that considerable relationship was appeared between the periodontal status and Ammonia gas (rM0.274, pM0.002), so, it should be needed to control Ammonia. Such dental Cares as the prevention or early treatment of periodontal disease and the accelerating the salivary flow as well as reducing the amounts and activities of filament or spiral typed oral micro-organism were recommended for adults, not only for dental care program at the dental clinics but also for public health programs, in order to promote the oral health and quality of file for individual and community peoples.

  • PDF