• 제목/요약/키워드: Modified IEC61888 method

검색결과 1건 처리시간 0.015초

A study on the uncertainty of setpoint for reactor trip system of NPPs considering rectangular distributions

  • Youngho Jin;Jae-Yong Lee;Oon-Pyo Zhu
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1845-1853
    • /
    • 2024
  • The setpoint of the reactor trip system shall be set to consider the measurement uncertainty of the instrument channel and provide a reasonable and sufficient margin between the analytical limit and the trip setpoint. A comparative analysis was conducted to find out an appropriate uncertainty combination method through an example problem. The four methods were evaluated; 1) ISA-67.04.01 method, 2) the GUM95 method, 3) the modified GUM method developed by Fotowicz, and 4) the modified IEC61888 method proposed by authors for the pressure instrument channel presented in ISA-RP67.04.02 example. The appropriateness of each method was validated by comparing it with the result of Monte Carlo simulation. As a result of the evaluation, all methods are appropriate when all measurement uncertainty elements are normally distributed as expected. But ISA-67.04 method and GUM95 method overestimated the channel uncertainty if there is a dominant input element with rectangular distribution among the uncertainty input elements. Modified GUM95 methods developed by Fotowicz and modified IEC61888 method by authors are able to produce almost the same level of channel uncertainty as the Monte Carlo method, even when there is a dominant rectangular distribution among the uncertainty components, without computer-assisted simulations.