• Title/Summary/Keyword: Modes of operation

Search Result 814, Processing Time 0.029 seconds

Analysis of a Harmonics Neutralized 48-Pulse STATCOM with GTO Based Voltage Source Converters

  • Singh, Bhim;Saha, Radheshyam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Multi-pulse topology of converters using elementary six-pulse GTO - VSC (gate turn off based voltage source converter) operated under fundamental frequency switching (FFS) control is widely adopted in high power rating static synchronous compensators (STATCOM). Practically, a 48-pulse ($6{\times}8$ pulse) configuration is used with the phase angle control algorithm employing proportional and integral (PI) control methodology. These kinds of controllers, for example the ${\pm}80MVAR$ compensator at Inuyama switching station, KEPCO, Japan, employs two stages of magnetics viz. intermediate transformers (as many as VSCs) and a main coupling transformer to minimize harmonics distortion in the line and to achieve a desired operational efficiency. The magnetic circuit needs altogether nine transformers of which eight are phase shifting transformers (PST) used in the intermediate stage, each rating equal to or more than one eighth of the compensator rating, and the other one is the main coupling transformer having a power rating equal to that of the compensator. In this paper, a two-level 48-pulse ${\pm}100MVAR$ STATCOM is proposed where eight, six-pulse GTO-VSC are employed and magnetics is simplified to single-stage using four transformers of which three are PSTs and the other is a normal transformer. Thus, it reduces the magnetics to half of the value needed in the commercially available compensator. By adopting the simple PI-controllers, the model is simulated in a MATLAB environment by SimPowerSystems toolbox for voltage regulation in the transmission system. The simulation results show that the THD levels in line voltage and current are well below the limiting values specified in the IEEE Std 519-1992 for harmonic control in electrical power systems. The controller performance is observed reasonably well during capacitive and inductive modes of operation.

A Study on Non Destructive Evaluation of the Steam Turbine L-0 Blades

  • Mizanur, Rahman Md.;Rezk, Osama;Ouma, Victor Otieno;Vaysidin, Saidov;Gomaa, M. Abdullatif;Jung, JaeCheon;Lee, YongKwan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.59-71
    • /
    • 2016
  • The Nuclear and Fossil Steam Turbines record a considerable number of failures annually. Some of these failures reported are as result of blade failure. The failure of the L-0 blade in a Steam Turbine is one of the most reported blade failure in Nuclear and Fossil steam turbines. This paper seeks to identify the best Non Destructive Evaluation (NDE) method or methods to be used in the steam turbine L-0 blades inspection process. The development of systems engineering processes presents an opportunity to apply NDE inspection to the L-0 blades. This process apply computer modelling of the L-0 using ANSYS and by simulating the stresses experienced by the L-0 blade during operation it is possible to identify the most susceptible areas for crack formation and growth. The results from these models compared to industry data for validation. The analysis of these results used to predict the most probable failure location and failure modes. Therefore NDE inspection can be applied to these areas with greater degree of accuracy. This would be beneficial in the increasing the accuracy in the detection of cracks and hence save inspection time and the overall inspection cost. Furthermore, not only the location for crack formation and NDE inspection determined but also best the NDE inspection technique/techniques to be applied appropriately on the L-0 blade are prescribed.

Blind Equalization of Digital Television Broadcasting Signals in Dynamic Multipath Channels (다이내믹 다중경로 채널에서의 디지털 텔레비전 방송 신호에 대한 블라인드 등화)

  • 오길남
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.5
    • /
    • pp.269-274
    • /
    • 2004
  • In this paper, proposed is the dual-mode algorithm of blind decision feedback equalizer (DFE) for digital terrestrial television signals. According to channel impairments, the proposed dual-mode algorithm for blind DFE operates in decision-directed mode or in blind mode of operation. The error signals being used in tap update of the equalizer are generated in the best mode of operations, so that the confidence of equalizer tap coefficient update is more accurate. As a result, it is possible to track the channel characteristics variations by automatic switching over between two modes of operations. For 8-level vestigial sideband modulated digital television signals, the mean square errors and symbol error rates of the proposed algorithm are compared with those of conventional methods. And the usability of the proposed scheme is assessed by computer simulations under various static and dynamic multipath channel environments.

Energy Efficient Sequential Sensing in Multi-User Cognitive Ad Hoc Networks: A Consideration of an ADC Device

  • Gan, Xiaoying;Xu, Miao;Li, He
    • Journal of Communications and Networks
    • /
    • v.14 no.2
    • /
    • pp.188-194
    • /
    • 2012
  • Cognitive networks (CNs) are capable of enabling dynamic spectrum allocation, and thus constitute a promising technology for future wireless communication. Whereas, the implementation of CN will lead to the requirement of an increased energy-arrival rate, which is a significant parameter in energy harvesting design of a cognitive user (CU) device. A well-designed spectrum-sensing scheme will lower the energy-arrival rate that is required and enable CNs to self-sustain, which will also help alleviate global warming. In this paper, spectrum sensing in a multi-user cognitive ad hoc network with a wide-band spectrum is considered. Based on the prospective spectrum sensing, we classify CN operation into two modes: Distributed and centralized. In a distributed network, each CU conducts spectrum sensing for its own data transmission, while in a centralized network, there is only one cognitive cluster header which performs spectrum sensing and broadcasts its sensing results to other CUs. Thus, a wide-band spectrum that is divided into multiple sub-channels can be sensed simultaneously in a distributed manner or sequentially in a centralized manner. We consider the energy consumption for spectrum sensing only of an analog-to-digital convertor (ADC). By formulating energy consumption for spectrum sensing in terms of the sub-channel sampling rate and whole-band sensing time, the sampling rate and whole-band sensing time that are optimal for minimizing the total energy consumption within sensing reliability constraints are obtained. A power dissipation model of an ADC, which plays an important role in formulating the energy efficiency problem, is presented. Using AD9051 as an ADC example, our numerical results show that the optimal sensing parameters will achieve a reduction in the energy-arrival rate of up to 97.7% and 50% in a distributed and a centralized network, respectively, when comparing the optimal and worst-case energy consumption for given system settings.

Determination of stay cable force based on effective vibration length accurately estimated from multiple measurements

  • Chen, Chien-Chou;Wu, Wen-Hwa;Huang, Chin-Hui;Lai, Gwolong
    • Smart Structures and Systems
    • /
    • v.11 no.4
    • /
    • pp.411-433
    • /
    • 2013
  • Due to its easy operation and wide applicability, the ambient vibration method is commonly adopted to determine the cable force by first identifying the cable frequencies from the vibration signals. With given vibration length and flexural rigidity, an analytical or empirical formula is then used with these cable frequencies to calculate the cable force. It is, however, usually difficult to decide the two required parameters, especially the vibration length due to uncertain boundary constraints. To tackle this problem, a new concept of combining the modal frequencies and mode shape ratios is fully explored in this study for developing an accurate method merely based on ambient vibration measurements. A simply supported beam model with an axial tension is adopted and the effective vibration length of cable is then independently determined based on the mode shape ratios identified from the synchronized measurements. With the effective vibration length obtained and the identified modal frequencies, the cable force and flexural rigidity can then be solved using simple linear regression techniques. The feasibility and accuracy of the proposed method is extensively verified with demonstrative numerical examples and actual applications to different cable-stayed bridges. Furthermore, several important issues in engineering practice such as the number of sensors and selection of modes are also thoroughly investigated.

A Single-Phase Quasi Z-Source AC-AC Converter with a Series Connection of the Output Terminals (출력이 직렬 결합된 단상 Quasi Z-소스 AC-AC 컨버터)

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.415-429
    • /
    • 2011
  • In this study, a single-phase quasi Z-source AC-AC converters with a series connection of the output terminals is proposed. The proposed system has configuration that the input terminals of two quasi Z-source AC-AC converters are connected in parallel and its output terminals are connected in series. The out of phase mode and in phase mode of the proposed system are presented. To verify the validity of the proposed converter, a DSP controlled hardware was made and PSIM simulation was executed. As a result, controlling the duty ratio of the converter, the desired buck-boost output voltages could be generated. For each modes, as compared with the single converter operation, the proposed converter could enhance the efficiency and input power factor according to different loads. Also, in case of the out of phase mode under the constant load, the efficiency and input power factor of the proposed system are increased 10[%], 35[%] respectively in compared with the single converter. And, the output voltage is constantly controlled in dynamic state in case while the load is suddenly changed.

Design of digitally controlled CMOS voltage mode DC-DC buck converter for high resolution duty ratio control (고해상도 듀티비 제어가 가능한 디지털 제어 방식의 CMOS 전압 모드 DC-DC 벅 변환기 설계)

  • Yoon, KwangSub;Lee, Jonghwan
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1074-1080
    • /
    • 2020
  • This paper proposes a digitally controlled buck converter insensitive to process, voltage and temperature and capable of three modes of operation depending on the state of the output voltage. Conventional digital-controlled buck converters utilized A/D converters, counters and delay line circuits for accurate output voltage control, resulting in increasing the number of counter and delay line bits. This problem can be resolved by employing the 8-bit and 16-bit bidirectional shift registers, and this design technique leads a buck converter to be able to control duty ratio up to 128-bit resolution. The proposed buck converter was designed and fabricated with a CMOS 180 nano-meter 1-poly 6-metal process, generating an output voltage of 0.9 to 1.8V with the input voltage range of 2.7V to 3.6V, a ripple voltage of 30mV, and a power efficiency of up to 92.3%. The transient response speed of the proposed circuit was measured to be 4us.

A study on Practical Countermeasures of Copyright Appraisal with the Amendment of Civil Procedure Act in 2016 (민사소송법 개정에 따른 저작권 감정 제도의 실무적 대응 방안)

  • Kim, Si Yeol
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • The March 29, 2016, amendment to the Civil Procedure Act introduced changes to the appraisal procedures, including new obligations for appraisers, changes in the modes of appraiser testimony, and questioning of appraisers through video conferencing, with all seemingly aimed at procedurally addressing the issues with appraisal in the context of court proceedings. The changes introduced by the amendment also affect the appraisal procedures for copyrights. In light of the above, this article examines how the amendment to the Civil Procedure Act affects the appraisal procedures for copyrights. Specific issues covered by this paper include: appointment of additional appraisers, prohibition of delegated appraisal, operation of the multiple appraisal system, disclosure of participating experts, proximity of the appraiser system, and congruence of areas of expertise.

After Lasek Surgeried and TransPRK Surgeried for Myopia, Comparison of High-order Aberrations (근시에서의 라섹과 TransPRK라섹 수술 후 고위수차 비교)

  • Park, Jun-Sung
    • Journal of Korean Clinical Health Science
    • /
    • v.3 no.2
    • /
    • pp.372-377
    • /
    • 2015
  • Purpose: The aim of this study is to compare total high order aberrations between surgery which uses TransPRK and general laser assisted sub-epithelial keratomileusis. Methods: The patients who had general laser assisted sub-epithelial and TransPRK laser assisted sub-epithelial by visiting ophthalmic clinic in Ulsan from January 2014 to August 2014 was researched. Results: When comparing total high order aberrations before and after operation, it was found that total high order aberration in general laser assisted sub-epithelial group increased to $0.222{\pm}0.078{\mu}m$ from $0.074{\pm}0.019{\mu}m$ while that in TransPRK assisted sub-epithelial group increased to $0.179{\pm}0.045{\mu}m$ from $0.076{\pm}0.032{\mu}m$. When comparing the increment in total high order aberrations between two groups after surgery, it was found that the increments of TransPRK assisted sub-epithelial group were statistically smaller than that of general laser assisted sub-epithelial group (p<0.05). Conclusions: This study made a comparative analysis of total high order aberrations between general laser assisted sub-epithelial and TransPRK assisted sub-epithelial which was introduced recently and the result showed a significant difference. The findings of this study suggest that TransPRK assisted sub-epithelial can be used widely in simply improving eye sight and quality of vision by reducing an increase in high order aberration caused by orthokeratology surgery. It is expected that TransPRK assisted sub-epithelial will be helpful for improving the understanding quality of eye sight which occurs by several methods of vision correction surgery.

Development of Cube Satellite's Communication System Using Commercial UHF Half-Duplex Antenna (상용 반이중 통신방식 UHF대역 송·수신겸용 안테나를 적용한 큐브위성의 통신시스템 구현)

  • Chae, Bong-Geon;Ha, Heon-Woo;Jang, Su-Eun;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.6
    • /
    • pp.522-528
    • /
    • 2014
  • A UHF/VHF full-duplex communication using monopole and dipole antenna has been widely used for cube satellite applications. This kind of communication system requires a dedicated structure panel for antenna integration, which is the one of the disadvantages of the conventional communication system from the accommodation point of view considering the extremely limited volume of the cube satellite. In this study, to maximize the accommodation efficiency of the cube satellite, the commercial UHF half-duplex antenna combined with buck converter for communication modes transition has been considered in the communication system design. Its effectiveness has been verified through link budget analysis based on the antenna specifications and satellite's operation conditions. In addition, the antenna deployment mechanism for the synchronous release of multi-antennas has also been introduced.