A comparative study of established z score models for coronary artery diameters in 181 healthy Korean children

  • Ryu, Kyungguk;Yu, Jeong Jin;Jun, Hyun Ok;Shin, Eun Jung;Heo, Young Hee;Baek, Jae Suk;Kim, Young-Hwue;Ko, Jae-Kon
    • Clinical and Experimental Pediatrics
    • /
    • 제60권11호
    • /
    • pp.373-378
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the statistical properties of four previously developed pediatric coronary artery z score models in healthy Korean children. Methods: The study subjects were 181 healthy Korean children, whose age ranged from 1 month to 15 years. The diameter of each coronary artery was measured using 2-dimensional echocardiography and converted to the z score in the four models (McCrindle, Olivieri, Dallaire, and Japanese model). Descriptive statistical analyses and 1-sample t tests were performed. Results: All calculated z scores had P values of ${\geq}0.050$ using the Kolmogorov-Smirnov test. The one sample t test showed that the mean z scores did not converge to zero except in 1 model, and the mean right coronary artery (RCA) z score was less than zero in all 4 models. The smaller RCA diameter in this study could be associated with the more distal measuring point used to avoid the conal branch. The percentage of subjects with extreme z score values (${\geq}2.0$ and ${\geq}2.5$) for the left main coronary artery (LMCA) seems to be higher in the Dallaire (4.9% and 3.3%) and Japanese models (7.1% and 3.8%). Conclusion: All 4 models showed statistical feasibility of normal distribution. More precise instructions would be needed for the measurement of the RCA. The higher percentage of extreme z scores for the LMCA is compatible with the basic understanding of anatomic variation in the LMCA.

다양한 하악 이부 확장 패턴에 관한 연구 (Biomechanics in various mandibular widening procedures)

  • 태기출;강경화;김경환
    • 대한치과교정학회지
    • /
    • 제35권1호
    • /
    • pp.82-89
    • /
    • 2005
  • 하악 이부 확장은 해부학적으로 가동성인 하악골에서 시행하는 견인골 신장술의 한 형태로 곡면화된 표면과 하악 과두, 좁은 치열궁 형태로 많은 제약을 받게 된다. 본 연구는 이러한 한계를 보완하기 위해 적용되는 다양한 형태의 이부 확장을 이해하기 위해 시도되었다 골 절단선의 위치와 견인 장치의 위치를 다르게 하여. 각 8가지 군으로 구분한 후 이부 확장을 시행하였다. 이부 확장은 견인기의 위치와 골 절단선의 형태에 따라 다르게 이루어지는 결과를 얻었다.

Event-based scenario manager for multibody dynamics simulation of heavy load lifting operations in shipyards

  • Ha, Sol;Ku, Namkug;Roh, Myung-Il
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권1호
    • /
    • pp.83-101
    • /
    • 2016
  • This paper suggests an event-based scenario manager capable of creating and editing a scenario for shipbuilding process simulation based on multibody dynamics. To configure various situation in shipyards and easily connect with multibody dynamics, the proposed method has two main concepts: an Actor and an Action List. The Actor represents the anatomic unit of action in the multibody dynamics and can be connected to a specific component of the dynamics kernel such as the body and joint. The user can make a scenario up by combining the actors. The Action List contains information for arranging and executing the actors. Since the shipbuilding process is a kind of event-based sequence, all simulation models were configured using Discrete EVent System Specification (DEVS) formalism. The proposed method was applied to simulations of various operations in shipyards such as lifting and erection of a block and heavy load lifting operation using multiple cranes.

개인 맞춤형 장치를 이용한 디지털 교정치료 (Digital Orthodontics using Customized Appliance System)

  • 김윤지;하혜정;이성종;이언화;류재준
    • 대한치과의사협회지
    • /
    • 제54권2호
    • /
    • pp.134-141
    • /
    • 2016
  • Use of ready-made orthodontic appliance can lead to inefficiencies in the final stages of the orthodontic treatment. Because patients' teeth have anatomic variations, brackets that have been designed to fit on average tooth surface may result in positional discrepancies when leveling and alignment is completed. As a result, additional steps such as rebonding, wire bending and use of auxiliaries may be needed. Even in patients who have normal tooth anatomy and proper tooth size relationships, precise bracket placement is crucial in order to efficiently control the tooth positions. Digital models can provide advantages in clinical orthodontics as virtual tooth setup could be performed, and clinicians can easily visualize the predicted final occlusion. Through this setup model, customized brackets with individualized prescription and archwires that optimally fit with the patients' dental arches can be produced using CAD/CAM technology. Also, the brackets can be accurately placed with an aid of 3D-printed jigs. The purpose of this article is to introduce the commonly used labial and lingual customized orthodontic appliance systems using digital technology.

  • PDF

Mandibular intraosseous squamous cell carcinoma lesion associated with odontogenic keratocyst: a case report

  • Park, Han-Kyul;Kim, Tae-Seop;Geum, Dong-Ho;Yoon, Sang-Yong;Song, Jae-Min;Hwang, Dae-Seok;Cho, Yeong-Cheol;Kim, Uk-Kyu
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권2호
    • /
    • pp.78-83
    • /
    • 2015
  • Squamous cell carcinoma (SCC) is the most common malignant tumor in the oral cavity, and it accounts for about 90% of all oral cancers. Several risk factors for oral SCC have been identified; however, SCC associated with odontogenic keratocysts have rarely been reported. The present study describes the case of a 36-year-old man with SCC of the right ramus of the mandible, which was initially diagnosed as a benign odontogenic cyst. He underwent enucleation at another hospital followed by segmental mandibulectomy and fibular free flap reconstruction at our institution. In this case, we introduce a patient with oral cancer associated with odontogenic cyst on the mandible and report a satisfactory outcome with wide resection and immediate free flap reconstruction.

White radish and swine scapular cartilage models for auricular framework carving training

  • Hwang, Kun
    • 대한두개안면성형외과학회지
    • /
    • 제21권4호
    • /
    • pp.225-228
    • /
    • 2020
  • Background: The aim of this study is to develop a two-stage training module using radish and swine scapular cartilage for carving ear cartilage. Methods: In the first stage, white radish was cut in 3-6 mm thick slices. The ear cartilage framework was carved using a graver and the helix and antihelix were fixed with pins. In the second stage, swine scapular cartilage was obtained. The thickness varied 3-6 mm. The ear cartilage framework was made. And triangular fossa and scaphoid fossa were carved with graver. A curvilinear cartilage for helix was assembled to the framework by pin fixing. Six participants were recruited for an ear reconstruction training workshop and figures of the cartilage framework were provided. Participants were asked answer the pre-workshop questionnaire and post-workshop questionnaire on a Likert scale to rate their satisfaction with the outcome. Results: On the pre-workshop questionnaire, participants indicated that they did not have sufficient knowledge and skill for fabricating the ear cartilage framework (1.5±0.5 using white radish; 1.3±0.5 using swine scapular cartilage). On the post-workshop questionnaire, participants responded that they had learned useful knowledge from this workshop, reflecting a significant improvement (3.8±1.0 using white radish; 4.0±1.1 using swine scapular cartilage). They also indicated that they had become somewhat confident in this skill (4.2±0.8 using white radish; 4.3±0.5 using swine scapular cartilage. The participants generally found the workshop satisfactory (practically helpful, 4.7±0.5; knowledge improved, 4.8±0.4; satisfied with course, 4.5±0.5; would recommend to others, 4.8±0.4). Conclusion: This model can be useful for ear reconstruction training for medical personnel.

The mechanism of human neural stem cell secretomes improves neuropathic pain and locomotor function in spinal cord injury rat models: through antioxidant, anti-inflammatory, anti-matrix degradation, and neurotrophic activities

  • I Nyoman Semita;Dwikora Novembri Utomo;Heri Suroto;I Ketut Sudiana;Parama Gandi
    • The Korean Journal of Pain
    • /
    • 제36권1호
    • /
    • pp.72-83
    • /
    • 2023
  • Background: Globally, spinal cord injury (SCI) results in a big burden, including 90% suffering permanent disability, and 60%-69% experiencing neuropathic pain. The main causes are oxidative stress, inflammation, and degeneration. The efficacy of the stem cell secretome is promising, but the role of human neural stem cell (HNSC)-secretome in neuropathic pain is unclear. This study evaluated how the mechanism of HNSC-secretome improves neuropathic pain and locomotor function in SCI rat models through antioxidant, anti-inflammatory, anti-matrix degradation, and neurotrophic activities. Methods: A proper experimental study investigated 15 Rattus norvegicus divided into normal, control, and treatment groups (30 µL HNSC-secretome, intrathecal in the level of T10, three days post-traumatic SCI). Twenty-eight days post-injury, specimens were collected, and matrix metalloproteinase (MMP)-9, F2-Isoprostanes, tumor necrosis factor (TNF)-α, transforming growth factor (TGF)-β, and brain derived neurotrophic factor (BDNF) were analyzed. Locomotor recovery was evaluated via Basso, Beattie, and Bresnahan scores. Neuropathic pain was evaluated using the Rat Grimace Scale. Results: The HNSC-secretome could improve locomotor recovery and neuropathic pain, decrease F2-Isoprostane (antioxidant), decrease MMP-9 and TNF-α (anti-inflammatory), as well as modulate TGF-β and BDNF (neurotrophic factor). Moreover, HNSC-secretomes maintain the extracellular matrix of SCI by reducing the matrix degradation effect of MMP-9 and increasing the collagen formation effect of TGF-β as a resistor of glial scar formation. Conclusions: The present study demonstrated the mechanism of HNSC-secretome in improving neuropathic pain and locomotor function in SCI through antioxidant, anti-inflammatory, anti-matrix degradation, and neurotrophic activities.

가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析) (Photoelastic Stress Analysis of Fixed Partial Dentures)

  • 조원행
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE)

  • 정창모
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

핵의학 영상기기의 최근 진보 (Recent Advances in Nuclear Medicine Imaging Instrumentation)

  • 정진호;최용;홍기조;민병준;호위;강지훈
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.98-111
    • /
    • 2008
  • This review introduces advances in clinical and pre-clinical single photon emission computed tomography (SPECT) and positron emission tomography (PET) providing noninvasive functional images of biological processes. Development of new collimation techniques such as multi-pinhole and slit-slat collimators permits the improvement of system spatial resolution and sensitivity of SPECT. Application specific SPECT systems using smaller and compact solid-state detector have been customized for myocardial perfusion imaging with higher performance. Combined SPECT/CT providing improved diagnostic and functional capabilities has been introduced. Advances in PET and CT instrumentation have been incorporated in the PET/CT design that provide the metabolic information from PET superimposed on the anatomic information from CT. Improvements in the sensitivity of PET have achieved by the fully 3D acquisition with no septa and the extension of axial field-of-view. With the development of faster scintillation crystals and electronics, time-of-flight (TOF) PET is now commercially available allowing the increase in the signal-to-noise ratio by incorporation of TOF information into the PET reconstruction process. Hybrid PET/SPECT/CT systems has become commercially available for molecular imaging in small animal models. The pre-clinical systems have improved spatial resolution using depth-of-interaction measurement and new collimators. The recent works on solid state detector and dual modality nuclear medicine instrumentations incorporating MRI and optical imagers will also be discussed.