• Title/Summary/Keyword: Modeling of PLC

Search Result 35, Processing Time 0.02 seconds

A Study on the Application of Voltage Transformer at Transmission Lines (송전선로측 권선형 변성기 사용에 따른 기술적 고찰)

  • Choi, Ky-Youl;Park, Moon-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1152-1154
    • /
    • 1999
  • Recently. due to the drastic development of communication method between substations for pilot protective relaying system. The power line carrier(PLC) application is getting obsolete. Consequently, the coupling capacitor voltage transformer (CCVT) loses its necessity for the carrier coupling function, and so wound voltage transformer(VT) can be used to substitute CCVT for voltage signal. However, VT has been reported to give rise to ferro-resonance phenomena, so sufficient consideration on applying the VT to line side is required. This study introduces probable technical problems in using the VT on T/L side, and carries out feasibility study on the basis of modeling results by EMTP(Electro-magnetic transient program)

  • PDF

A Study on the Low Power Line Modulation and Power Line Channel Modeling (저압 전력선 통신 변조 기법 및 전력선 채널 특성)

  • Kand Duk-Ha;Heo Yoon-Seok;Cho Ki-Hyung;Lee Dae-Young
    • The Journal of Information Technology
    • /
    • v.5 no.4
    • /
    • pp.1-8
    • /
    • 2002
  • This thesis is about power line communication(PLC) over the low voltage grid. The main advantage with power line communication is the use of an existing infrastructure. The PLC channel can be modeled as having multi-path propagation with frequency-selective fading, typical power lines exhibit signal attenuation increasing with length and frequency. OFDM(Orthogonal Frequency Division Multiplexing) is a modulation technique where multiple low data rate carriers are combined by a transmitter to form a composite high data rate transmission. To implement the multiple carrier scheme using a bank of parallel modulators would not be very efficient in analog hardware. Each carrier in an OFDM is a sinusoid with a frequency that is an integer multiple of a base or fundamental sinusoid frequency. Therefore, each carrier is a like a Fourier series component of the composite signal. In fact, it will be shown later that an OFDM signal is created in the frequency domain, and then transformed into the time domain via the Discrete Fourier Transform(DFT).

  • PDF

NFC antenna modeling and design for position information collecting of steel pallet for screw transfer (나사 이송용 철재 파렛트의 위치 정보 수집을 위한 NFC 안테나 모델링 및 설계)

  • Lee, Eun-kyu;Kim, Dong-wan;Lee, Sang-wan;Kim, Jae-joong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.12
    • /
    • pp.1675-1683
    • /
    • 2018
  • This paper is a study on modeling of an NFC antenna to be inserted into a steel pallet for conveying selected good products through a vision system to a threaded screw from CNC equipment. The CNC equipment used here incorporates the information communication technology (ICT) corresponding to the Internet of Things (IoT), and the smart factory system technology that produces information by exchanging information freely in two directions by connecting the POP corresponding to the service Internet is evolved Equipment. Therefore, it is possible to collect position information on the threaded workpiece by applying NFC antenna designed considering iron pallet used for material management so as to grasp estimated completion time and actual production amount according to production instruction from existing analog type equipment to POP monitoring system And investigated its characteristics.

Design of Level 2 Control System for Continuous Reheat Furnaces (연속식 가열로의 Level 2 제어 시스템 설계)

  • Ryu, BoHyun;Lee, JaeYong;Rhim, DongRyul;Cha, JaeMin;Yeom, ChoongSub
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.12 no.1
    • /
    • pp.113-120
    • /
    • 2016
  • Steel in a continuous reheat furnace is heated to higher temperature to be treated in the rolling steel process. Due to this reason the continuous reheat furnace system requires an optimal control system to adjust the temperature inside the furnace. Level 2 control systems for continuous reheat furnaces generate automatic heating set points for the level 1 system of the furnace based on the mathematical thermal model which can give a good estimation of steel heating inside the furnace and is used to adjust heating requirements to optimize furnace combustion. For the current study the analytic methodology based on the design procedure from the systems engineering to develop new level 2 control system of a continuous reheat furnace was proposed. The system analysis and the requirements of the level 2 control system were derived using the unified modeling language (UML) 2.0, and the design of database and the graphic user interface (GUI) for the level 2 control system were conducted.

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.