• Title/Summary/Keyword: Model pump

Search Result 934, Processing Time 0.031 seconds

A Study on Serum Glucose Levels and the Pancreatic Beta-cell Protective Effect of Acupuncture on Streptozotocin-treated Rats by Subcutaneous Implantation of Osmotic Pump (Osmotic Pump모델 당뇨병 실험동물에서 침자극이 혈당조절 및 베타세포 보호작용에 미치는 영향)

  • Hur, Kwang-Wook;Kang, Sung-Gil;Kim, Yong-Suk
    • Journal of Acupuncture Research
    • /
    • v.24 no.4
    • /
    • pp.115-124
    • /
    • 2007
  • Objective: To evaluate the effect of acupuncture on streptozotocin(STZ)-treated rats by subcutaneous implantation of osmotic pump. Methods: STZ was administered to rats at a low dose with osmotic pump to induce beta cell death and diabetes (STZ osmotic pump model), The experimental animals were divided into 4 groups: 1. The control group which was not treated in the STZ osmotic pump model 2. The sham group which was acupunctured at an arbitrary point in the STZ osmotic pump model 3. The sample A group which was acupunctured at the Chung-wan($CV_{12}$) in the STZ osmotic pump model 4. The sample B group which was acupunctured at the Chok-samni($ST_{36}$) in the STZ osmotic pump model. The effect of acupuncture in the STZ osmotic pump model was observed by measuring the serum glucose level and immunostaining of pancreatic tissue of the rats. Results : STZ injection by subcutaneous implantation of osmotic pump caused hyperglycemia by destroying the pancreatic beta cell selectively. Acupuncture at the Chung-wan acupuncture point($CV_{12}$) and Jhok-samni acupuncture point ($ST_{36}$) in the STZ osmotic pump model separately resulted in a decrease of the serum glucose level. In addition, the cyto-protective effect of the pancreatic beta-cell was detected in the STZ osmotic pump model by acupuncture. And there were few differences between the effects of acupuncture at the CV12 and $ST_{36}$. Conclusion : Acupuncture at the CV12 and ST36 had beneficial effects on Type II diabetes mellitus, and action mechanism of the effect was thought to be concerned with secretion of endogenous beta-endorphin.

  • PDF

Experiment of Flux pump for High Temperature Superconductor Insert coils of NMR magnets (NMR 자석용 고온 초전도 내부 코일을 위한 플럭스 폄프에 대한 실험)

  • 정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.15-20
    • /
    • 2001
  • This paper describes a model flux pump experiment recently performed at the MIT Francis Bitter Magnet Laboratory. The results of the model flux pump will be used in the development of a prototype flux pump that will be couple to a high-temperature superconductor (HTS) insert coil of a high-field NMR (Nuclear Magnetic Resonance) magnet, Such an HTS insert is unlikely to operate in persistent model because of the conductors low index(n) The flux pump can compensate fro field decay in the HTS insert coil and make the insert operate effectively in persistent mode . The flux pump, comprised essentially of a transformer an two switches. all made of superconductor, transfers into the insert coil a fraction of a magnetic energy that is first introduced in the secondary circuit of the transformer by a current supplied to the primary circuit. A model flux pump has been designed. fabricated, and operated to demonstrate that a flux pump can indeed supply a small metered current into a load superconducting magnet. A current increment in the range of microamperes has been measured in the magnet after each pumping action. The superconducting model flux pump is made of Nb$_3$ Sn tape, The pump is placed in a gaseous environment above the liquid helium level to keep its heat dissipation from directly discharged in the liquid: the effluent helium vapor maintains the thermal stability of the flux pump.

  • PDF

Evaluation for the Numerical Model of a Micro-Bubble Pump (미세버블펌프 수치모델평가 및 검증)

  • LEE, SANG-MOON;JANG, CHOON-MAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.121-126
    • /
    • 2016
  • Hydraulic performance of a micro-bubble pump has been analyzed by numerical simulation and experimental measurements. Flow recirculation apparatus between the pump inlet and outlet reserviors has been adopted to measure pump performance according to flow conditions sequentially. To analyze three-dimensional flow field in the micro-bubble pump, general analysis code, CFX, is employed. SST turbulence model is employed to estimate the eddy viscosity and compared the pump performance to k-${\varepsilon}$ model. Unstructured grids are used to represent a composite grid system including blade, casing and inlet casing. It is found that the numerical model used in the present study is effective to evaluate the pump performance. From the numerical simulation, low velocity region due to pressure loss is decreased where pump efficiency has maximum value. Detailed flow field inside the micro-bubble pump is also analyzed and compared.

A Study of Performance Improvement of a Vaporizer Sea-Water Pump (기화해수펌프 성능 개선에 대한 연구)

  • Kim, Yang-Ik;Chung, Kyung-Nam
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.645-649
    • /
    • 2005
  • In this study, redesign of a vaporizer sea-water pump has been carried out using computational fluid dynamics. The flow field of the specified pump model is simulated and analyzed. In the flow analysis full pump model has been used, and multi-block grids are employed to solve the governing equations. In order to improve pump efficiency, systematic redesign has been performed to remove the flow recirculation near the hub of the diffuser vanes. The modified model shows about 4 % improvement in pump efficiency compared to the given model.

  • PDF

Exact analysis for overload of a charge-pump phase-locked loop (Charge-pump 위상 동기 회로의 과부하에 대한 정확한 해석)

  • 최은창;이범철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3069-3085
    • /
    • 1996
  • This paper shows an accurate charge-pump PLL model which considers the wave-form distortion in high speed operation of charge-pump PLL, the leakage current in loop filter, and a physical limit in charge-pump. With proposed model of charge-pump PLL, overload and stability are derived theoretically and the results are compared to the conventional model. Unlike the ideal charge-pump PLL that simplifies calculations, it is possible to analyze the transient-state and the steady-state at the same time with proposed accurate model. Thus, charge-pump over load, in the transient-state and the stead-state of charge-pump, is accuragely analyzed and the results are confirmed with simulation.

  • PDF

Three Dimensional Simulation Model of Fuel Delivery Jet Pump (연료 송출용 제트펌프 3차원 전산해석 모델)

  • PARK, DAIN;YUN, JIN WON;YU, SANGSEOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.3
    • /
    • pp.308-314
    • /
    • 2017
  • Jet pump in automotive fuel tank module is used to deliver fuel to fuel pump so that the pump is operated without aeration in suction side. In this study, three dimensional simulation model of jet pump is developed to understand performance variation over design parameters. Performance of jet pump is also investigated experimentally in terms of operating pressures. The experimental data is used to verify the three dimensional simulation model of jet pump. Verification results show that the three dimensional simulation model of jet pump is about 1% error with experiment. The simulations are conducted in terms of throat ratio and primary flow induction angle. As the throat ratio is increased, the flux ratio is trade-off at 3 times of throat diameter. On the other hand, as primary flow induction angle is increased, vapor pressure inside the nozzle is decreased. In summary, the results show that liquid jet pump has to be optimized over design parameters. Additionally, high velocity of induced flow is able to evolve cavitation phenomena inside the jet pump.

Investigation of Experimental Results Using the Drying Model for a Heat Pump Dryer (열펌프 건조 해석 모델을 이용한 측정 결과의 분석)

  • Lee, Kong-Hoon;Kim, Ook-Joong;Kim, Jong-Ryul;Lee, Sang-Ryoul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2268-2273
    • /
    • 2008
  • The drying model has been used to obtain the fundamental information required to design the heat pump dryer with the simple thermodynamic model. In the model, the input conditions are crucial to obtain the acceptable results. The model includes one-stage heat pump cycle, simple drying process using the drying efficiency. The drying efficiency is defined with the conditions of inlet and outlet in the dryer. The experiment has been carried out in the pilot dryer with one-stage heat pump cycle. Refrigerant 134a is used in the heat pump cycle. In the dryer, some of drying air flows through the heat pump system and the rest of air bypasses the heat pump system and circulates through the drying chamber. Some operating conditions from the pilot dryer are used as input conditions of the model and the results are compared with experimental results for the validation.

  • PDF

Numerical Analysis on the Flow Uniformity in a Pump Sump Model with Multi Pump Intake (다중 흡수정을 갖는 펌프장 모델의 유동균일성 해석)

  • Choi, Jong-Woong;Choi, Young-Do;Lim, Woo-Seop;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.4
    • /
    • pp.14-22
    • /
    • 2009
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite basin with no close walls or floors and with no stray currents. Therefore, flow into the pump intake is with no vortices or swirling. However, pump station designers relying on these curves to define the operating conditions for the pump selected sometimes meet the reductions of capacity and efficiency, as well as the increase of vibration and additional noise, which were caused by air-entered flow in the pump station. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump of pump station model. Multi-intake sump model with anti-submerged vortex device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the vortex generation in the pump station accurately. The analysed results by CFD show that the vortex structure and effect of anti-submerged vortex device are different at each pump intake channel.

Analysis for bit synchronization using charge-pump phase-locked loop (비트 동기 Charge-pump 위상 동기 회로의 해석)

  • 정희영;이범철
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.1
    • /
    • pp.14-22
    • /
    • 1998
  • The Mathematic model of bit synchronization charge-pump Phase Locked Loop (PLL) is presented which takes into account the aperiodic reference pulses and the leakage current of the loop filter. We derive theoreitcal static phase error, overload and stability of bit synchronization charge-pump PLL using presented model and compare it with one of the conventional charge-pump PLL model. We can analysis bit synchronization charge-pump PLL exactly because our model takes into account the leakage current of the loop filter and aperiodic input data which are the charateristics of bit synchronization charge-pump PLL. We also verify it using HSPICE simulation with a bity synchronizer circuit.

  • PDF

Analysis of the Mathematical Model of a Variable Displacement Vane Pump for Engine Lubrication (엔진윤활용 가변 베인펌프의 수학적 모델 해석)

  • Truong, D.Q.;Ahn, K.K.;Lee, J.S.
    • Journal of Drive and Control
    • /
    • v.11 no.1
    • /
    • pp.14-24
    • /
    • 2014
  • Variable displacement vane-type oil pumps represent one of the most innovative pump types for industrial applications, especially for engine lubrication systems. This paper presents a complete and accurate mathematical model for a typical variable displacement vane-type oil pump. Firstly, its theoretical model is revised. Secondly, an analysis of power loss factors of this pump type is carefully investigated to optimize the modeling accuracy. Finally, the estimated pump performance using the complete pump model is verified by numerical simulations in comparison with the practical tests.