• Title/Summary/Keyword: Model chamber

Search Result 1,013, Processing Time 0.032 seconds

A Study on Analyzing Bottlenecks of Logistics in Incheon Port;Focused on Container Freight (인천항 물류애로요인 분석에 관한 연구;컨테이너 화물을 중심으로)

  • An, U-Cheol;An, Seung-Beom
    • Proceedings of the Korea Port Economic Association Conference
    • /
    • 2006.08a
    • /
    • pp.159-179
    • /
    • 2006
  • As the current trend to the main index of the port competitiveness evaluation, the competitiveness index of the port service comes to more important than the part of expense, location and facility. To reform the bottleneck of port has an effect on improving port service competitiveness. Therefore, this study shows the importance of analyzing bottlenecks on logistics to improve port competitiveness. It collected recent questionnaire data which are the subject as the Custom Service, the Chamber of Commerce and Industry, the Trade Association about bottlenecks of port logistics for working out bottlenecks of domestic port logistics and it produced the order of priorities of bottlenecks by multiplying each output priorities and weights of each process in user of Incheon inner-outer port which is focused on container freight by analysis of priority and Analytic Hierarchy Process(AHP). Unlike existing studies, this study has important values. It presents the priority evaluation only focused on the container freight was produced by port users who are categorized into shipping company, terminal operation company and forwarder, car-ferry in Incheon inner-outer port and making a application of logistics process. It means internal and external competitiveness improvement plan can be presented more concretely and detailed than past competitiveness attributes such as location, facility, service and expense. If the analysis of port logistics bottlenecks which was focused on container freight is extended to the part of general cargo and sundries such as haul grain, car, scrap iron, those studies will be able to provide Incheon port users with useful information and a model of analyzing overall bottleneck of logistics in Incheon port.

  • PDF

A Preliminary Configuration Design of Methane/Oxygen Bipropellant Small-Rocket-Engine through Theoretical Performance Analysis (이론성능해석에 의한 메탄/산소 이원추진제 소형로켓엔진의 예비형상설계)

  • Bae, Seong Hun;Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.47-53
    • /
    • 2015
  • Design parameters required for Methane/oxygen bipropellant small-rocket-engine were derived through a theoretical performance analysis. The theoretical performance of the rocket engine was analyzed by using CEA and optimal propellant mixture ratio, characteristic length, and optimal expansion ratio were calculated by assuming chemical equilibrium. A coaxial-type swirl injector was chosen because of its outstanding atomization performance and high combustion efficiency compared to other types of injector and also a bell nozzle with 80% of its full length was designed. The rocket engine configuration with 1.72 MPa of chamber pressure, 0.18 kg/s in total propellant mass flow, and O/F ratio of 2.7 was proposed as a ground-firing test model.

Investigation concerning Design Method of the Diffuser Expansion Ratio Commanding a Starting of the Second Throat Exhaust Diffuser for High Altitude Simulation (고도모사용 2차목 디퓨져 시동을 위한 디퓨져 팽창비 설계기법에 관한 연구)

  • Park, Sung-Hyun;Park, Byung-Hoon;Lim, Ji-Hwan;Yoon, Woong-Sup
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.299-304
    • /
    • 2008
  • Starting characteristics of the axi-symmetric second throat exhaust diffuser (STED) with zero-secondary flows are numerically investigated. Renolds-Average Navier-Stokes equations with a standard ${\kappa}-{\varepsilon}$ turbulence model incorporated with enhanced wall treatment are solved to simulate the diffusing evolutions of the nozzle plume. Minimum (optimum) starting pressure difference of 20$\sim$25% between 1-D theory and the measured data validated from previous results[5] is also applied to predict the range of an effective diffuser expansion ratio (Ad/At) in this system.

  • PDF

Research on the Surface Improvement of High Soft Ground Using Calibration Chamber Test (모형토조실험에 의한 초연약지반의 표층개량에 관한 연구)

  • Bang, Seongtaek;Yeon, Yongheum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.5
    • /
    • pp.39-46
    • /
    • 2019
  • Most of the soil used for reclamation is marine clay generated from dredging construction.The soft ground made of dredged clay has high water content and high compressibility, so the bearing capacity of the ground is very weak and it is difficult to enter the ground improvement equipment. Therefore, surface hardening treatment method is used to enter equipment prior to full-scale civil engineering work, and stabilizer is mainly used for cement series. Cement-based stabilizers have the advantage of improving the ground in a short period of time and have excellent economic efficiency, but they are disadvantageous in that they cause environmental problems due to leaching of heavy metals such as hexavalent chromium. In this study, environmental effects evaluation of dredged clay mixed with normal portland cement and environmentally friendly stabilizer was evaluated, and uniaxial compressive strength test and indoor model test were conducted to confirm the bearing capacity characteristics of the solidified layer.

The Study on Pressure Confine Effect of Blast Stemming Material and Plug Device Using Numerical Analysis Technique (수치해석 기법을 이용한 발파전색재료 및 플러그 장치의 폭발압 저항 효과에 관한 연구)

  • Ko, Younghun;Kwak, Kiseok;Seo, Seunghwan;Jeong, Youngjun;Kim, Sik;Chung, Moonkyung
    • Explosives and Blasting
    • /
    • v.40 no.2
    • /
    • pp.1-14
    • /
    • 2022
  • Numerical simulation is the most widely used methods for evaluating blasting performance. This study, conducted the numerical analysis of shock chamber model to evaluate the pressure confine effect of the stemming material and plug device. The stemming effect was compared and evaluated with that of the STF-based stemming material currently under development and sand, which is a commonly used blast stemming material. Furthermore, to verify of enhancement the confine effect inside blast hole pressure, three types of stemming plugs were adopted for the numerical analysis. The numerical simulation results revealed that the STF-based stemming materials were superior to the general stemming material. Also, It is evaluated that the STF-based stemming and Plug system can not only prevent detonation gas from overflowing the borehole prematurely, but also prolong the action time and scope of detonation gas in the borehole effective.

Tensile Properties of CERP Composite with Different Resin Composition under Cryogenic Temperature (극저온 환경에서 탄소섬유강화 복합재료의 수지조성변화에 따른 인장 물성 측정)

  • Kim, Myung-Gon;Kang, Sang-Guk;Kong, Cheol-Won;Kim, Chun-Gon
    • Composites Research
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2007
  • In this study, carbon fiber reinforced polymeric (CFRP) composites with different resin composition were manufactured and resin formulation in composite materials were presented through tensile tests for cryogenic use. Thermo-mechanical cyclic loading (up to 6 cycles) was applied to CFRP unidirectional laminate specimens from room temperature to $-150^{\circ}C$. Tensile tests were then performed at $-150^{\circ}C$ using an environmental test chamber. In addition, matrix-dominant properties such as the transverse and in-plane shear characteristics of each composite model were measured at $-150^{\circ}C$ to examine the effects of resin formulation on their interfacial properties. The tensile tests showed that the composite models with large amounts of bisphenol-A epoxy and CTBN modified rubber in their resin composition had good mechanical performance at cryogenic temperature (CT).

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

A Study on measurement of scattery ray of Computed Tomography (전산화 단층촬영실의 산란선 측정에 대한 연구)

  • Cho, Pyong-Kon;Lee, Joon-Hyup;Kim, Yoon-Sik;Lee, Chang-Yeop
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.37-42
    • /
    • 2003
  • Purpose : Computed tomographic equipment is essential for diagnosis by means of radiation. With passage of time and development of science computed tomographic was developed time and again and in future examination by means of this equipment is expected to increase. In this connection these authors measured rate of scatter ray generation at front of lead glass for patients within control room of computed tomographic equipment room and outside of entrance door for exit and entrance of patients and attempted to ind out method for minimizing exposure to scatter ray. Material and Method : From November 2001 twenty five units of computed tomographic equipments which were already installed and operation by 13 general hospitals and university hospitals in Seoul were subjected to this study. As condition of photographing those recommended by manufacturer for measuring exposure to sauter ray was use. At the time objects used DALI CT Radiation Dose Test Phantom fot Head (${\oint}16\;cm$ Plexglas) and Phantom for Stomache(${\oint}32\;cm$ Plexglas) were used. For measurement of scatter ray Reader (Radiation Monitor Controller Model 2026) and G-M Survey were used to Survey Meter of Radical Corporation, model $20{\times}5-1800$, Electrometer/Ion Chamber, S/N 21740. Spots for measurement of scatter ray included front of lead glass for patients within control room of computed tomographic equipment room which is place where most of work by gradiographic personnel are carried out and is outside of entrance door for exit and entrance of patients and their guardians and at spot 100 cm off from isocenter at the time of scanning the object. The results : Work environment within computed tomography room which was installed and under operation by each hospital showed considerable difference depending on circumstances of pertinent hospitals and status of scatter ray was as follows. 1) From isocenter of computed tomographic equipment to lead glass for patients within control room average distance was 377 cm. At that time scatter ray showed diverse distribution from spot where no presence was detected to spot where about 100 mR/week was detected. But it met requirement of weekly tolerance $2.58{\times}10^{-5}\;C/kg$(100 mR/week). 2) From isocenter of computed tomographic equipment to outside of entrance door where patients and their guardians exit and enter was 439 cm in average, At that time scatter ray showed diverse distribution from spot where almost no presence was detected to spot with different level but in most of cases it satisfied requirement of weekly tolerance of $2.58{\times}10^{-6}\;C/kg$(100 mR/week). 3) At the time of scanning object amount of scatter ray at spot with 100 cm distance from isocenter showed considerable difference depending on equipments. Conclusion : Use of computed tomographic equipment as one for generation of radiation for diagnosis is increasing daily. Compared to other general X-ray photographing field of diagnosis is very high but there is a high possibility of exposure to radiation and scatter ray. To be free from scatter ray at computed tomographic equipment room even by slight degree it is essential to secure sufficient space and more effort should be exerted for development of variety of skills to enable maximum photographic image at minimum cost.

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

Estimation of Cardinal Temperatures for Germination of Seeds from the Common Ice Plant Using Bilinear, Parabolic, and Beta Distribution Models

  • Cha, Mi-Kyung;Park, Kyoung Sub;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.34 no.2
    • /
    • pp.236-241
    • /
    • 2016
  • The common ice plant (Mesembryanthemum crystallinum L.) has some medicinal uses and recommended plant in closed-type plant factory. The objective of this study was to estimate the cardinal temperatures for seed germination of the common ice plant using bilinear, parabolic, and beta distribution models. Seeds of the common ice plant were germinated in the dark in a growth chamber at four constant temperatures: 16, 20, 24, and $28^{\circ}C$. For this, four replicates of 100 seeds were placed on two layers of filter paper in a 9-cm petri dish and radicle emergence of 0.1 mm was scored as germination. The times to 50% germination were 4.3, 2.5, 2.0, and 1.8 days at 16, 20, 24, and $28^{\circ}C$, respectively, indicating that the germination of this warm-weather crop increased with temperature. Next, the time course of germination was modeled using a logistic function. For the selection of an accurate model, seeds were germinated in the dark at constant temperatures of 6, 12, 32, and $36^{\circ}C$. Germination started earlier and increased rapidly at temperatures above $20^{\circ}C$. The minimum, optimal, and maximum temperatures were estimated by regression of the inverse of time to 50% germination rate, as a function of the temperature gradient. The different functions estimated differing minimum, optimal and maximum temperatures, with 5.7, 27.7, and $36.5^{\circ}C$, respectively for the bilinear function, 13.4, 25.0, and $36.6^{\circ}C$, respectively, for the parabolic function and 7.8, 25.9, and $36.0^{\circ}C$, respectively, for the beta distribution function. The models estimated that the inverse of time to 50% germination rate was 0 at 6 and $36^{\circ}C$. The observed final germination rates at 12 and $32^{\circ}C$ were 62 and 97%, respectively. Our data show that a beta distribution function provides a useful model for estimating the cardinal temperatures for germination of seed from the common ice plant.