• Title/Summary/Keyword: Model Combustor

Search Result 350, Processing Time 0.028 seconds

Combustion Instability Comprehension with Combustion Chamber Length in Dual Swirl Gas Turbine Model Combustor from Flame Behaviors (화염거동을 통한 이중선회 가스터빈 모델 연소기에서 연소실 길이에 따른 연소 불안정성 이해)

  • Jang, Munseok;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.233-235
    • /
    • 2015
  • This study is to investigate the combustion instability of the variation of combustion chamber length in dual swirl gas turbine model combustor. When equivalence ratio was fixed at 1.1, as the length of the combustion chamber increases the value of the frequency decreased in 7kW while the value of the frequency was constant in 4kW. The analysis of flame behaviors by high speed camera was conducted to identify such trend.

  • PDF

Combustion Instability Analysis Using Network Model in an Annular Gas Turbine Combustor (환형 가스터빈 연소기에서 네트워크 모델을 이용한 연소불안정 해석)

  • Pyo, Yeongmin;Yoon, Myunggon;Kim, Daesik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.3
    • /
    • pp.72-80
    • /
    • 2018
  • Combustion instabilities are caused by the feedback relationship between heat release perturbations and acoustic pressure oscillations in the combustor. Studies on the combustion instability in an annular combustor have recently received great attention due to the enhanced NOx requirement in aero-engines. In this study, a thermoacoustic network model was developed in order to calculate the acoustic characteristics for various modes in the annular combustor. The network model is combined with flame transfer function(FTF) in order to calculate the stability of the combustor. Numerical results are compared with measurement data.

Basic Study on Flame-Stabilization Characteristics in a Multi-Channel Combustor via a Model of a Porous-Media Combustor (다공성 연소기 모델로서의 다중 채널 연소기 내부 화염의 안정화 특성 기초 연구)

  • Park, Seung-Il;Lee, Min-Jung;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.815-823
    • /
    • 2011
  • Combustion phenomena in porous media combustors are widely used in industrial fields for the combustion of lowgrade fuels and the regeneration of combustion heat. However, studies of combustion phenomena in porous media have been limited, because these phenomena are difficult to observe, and the configurations of porous media are complex. We propose a simple model combustor: a multi-channel combustor that consists of many layers of combustion channels made of quartz plates. We conducted an experimental observation of the flames in the multi-channel combustor and obtained experimental results for the flame stabilization limits. Flames formulated in the multi-channel combustor showed variation in the spatial distribution depending on the heat transfer between neighboring channels. A simple analytical model was developed and the variation in the flammability limits of the multi-channel combustor was discussed. This study will enhance our understanding of flame behavior in a porous-media combustor.

Design Criterion for the Size of Micro-scale Pt-catalytic Combustor in Respect of Heat Release Rate (열 방출률에 대한 마이크로 백금 촉매 연소기의 치수 설계 기준)

  • Lee, Gwang Goo;Suzuki, Yuji
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.4
    • /
    • pp.49-55
    • /
    • 2014
  • Design criterion for the size of micro Pt-catalytic combustor is investigated in terms of heat release rate. One-dimensional plug flow model is applied to determine the surface reaction constants using the experimental data at stoichiometric butane-air mixture. With these reaction constants, the mass fraction of butane and heat release rate predicted by the plug flow model are in good agreement with the experimental data at the combustor exit. The relationship between the size of micro catalytic combustor and mixture flowrate is introduced in the form of product of two terms-the effect of fuel conversion efficiency, and the effect of chemical reaction rate and mass transfer rate.

Flame Propagation in a Micro Vessel under Excessive Heat Loss (과도한 열손실을 수반하는 초소형 정적연소실 내 화염전파)

  • Na, Han-Bee;Choi, Kwon-Hyoung;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.95-98
    • /
    • 2002
  • A numerical investigation on the flame propagation and extinction in a micro combustor is described. Previous measurements of $H_2-air$ flame propagation in a submilimeter scale combustor exhibited significance of wall effects on burning velocity and extinction. The heat transfer to wall becomes important not only in the cooling of burnt gases but also during the flame ropagation, which has be by and large ignored in macro scale combustor calculations. In order to take the heat loss into account the combustion calculation, we developed a numerical code with a heat transfer model that was determined empirically from measured data. PISO algorithm was used for differencing of conservation equations. $H_2-air$ reaction was modeled with 10 species - 16 steps. Comparison with measured data showed good agreement in flame propagation speed. Also the pressure decrease after flame extinction was accurately predicted by the model. A further study is desirable for a better quenching model that can predict the quenching location.

  • PDF

A Study on Flow Characterstics of Gas Turbine rvpe Combustor (II) - Flow Characteristics in Combustor - (가스터어빈형 연속류연소기의 유동에 관한 연구(II) -연소기내의 유동특성-)

  • 이근오;지용욱;김형섭
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.59-70
    • /
    • 1989
  • This paper deals with the experimental study on the flow characteristics in straight flow can type combustor which has been used for high pressure ratio gas turbine combustor. The author has investigated the effects of swirl number and secondary air hole arrays in axial position on the flow characteristics by adopting the tuft method and 5-Hole Pilot Tube. From these experiments, as the swirl number increases, the results obtained is that the area of recirculation zone becomes wide and the position of vortex-core region approaches to the near of fuel nozzle in the model combustor. The most favourable penetration is obtained when secondary air jet is introduced through the air holes distributed in the form of paralled two rows in axial position of model combustor.

  • PDF

An Experimental Investigation of Combustion Characteristics in a Model Combustor by Reproduction of GE 7FA+e DLN-2.6 Gas Turbine (GE 7FA+e DLN-2.6 연소기를 모사한 모형 가스터빈 연소기의 연소불안정 특성에 대한 실험적 연구)

  • Kim, Min-Ki;Lee, Jang-Su;Park, Seong-Soon;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.231-235
    • /
    • 2009
  • The mainly objectives of this study was a combustion dynamics and instability characteristics in a model dump type combustor which is scale down of GE 7FA+e DLN 2.6 gas turbine combustor with running at Seo-Inchon combined cycle power plant. Model gas turbine injector has 2-stage swirl vane and it's reduced 1/3 size of the original one. The shape of plenum and combustor were designed for similar acoustic characteristics. As the result, this research have been shows the peak frequency of model combustor was changed quarter-wave mode to Helmholtz resonator mode in plenum and longitudinal mode in dump combustor at unstable flame conditions caused by the different of combustor temperature and fuel-air mixture distributions.

  • PDF

Combustion Instability Analysis Using Network Model in an Annular Gas Turbine Combustor (네트워크 모델을 이용한 환형 가스터빈 연소기에서의 연소불안정 해석)

  • Pyo, Yeongmin;Yoon, Myunggon;Kim, Daesik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.896-904
    • /
    • 2017
  • Lean premixed combustion was successful in meeting current NOx emission regulations. However, these often leads to combustion instability. This phenomena results from the feedback relationship between heat release perturbations and acoustic pressure oscillations in the combustor. Researches on the combustion instability in an annular combustor have recently received great attention due to the enhanced NOx requirement in aero-engines. In this study, the thermoacoustic network model has been developed in order to calculate the acoustics for longitudinal as well as circumferential modes in the annular combustor. The combustion model in the network model is calculated by flame transfer function(FTF). Numerical and analytical results are compared to an measurement data.

  • PDF

Thermodynamic Modeling of Heat Loss and Quenching in a Down Scaled Combustor (형상 축소된 연소기의 열손실 및 소염해석 모델)

  • Lee, Dae-Hoon;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.7
    • /
    • pp.919-926
    • /
    • 2002
  • Down scaled combustor undergoes increased heat loss that results in incomplete combustion or quenching of the flame as a consequence. Therefore, effect of enhanced heat loss should be understood to design a MEMS scale combustion devices. Existing combustion models are inadequate for micro combustors because they were developed for analysis of regular scale combustor where heat loss can be ignored during the flame propagation. In this research a combustion model is proposed in order to estimate the heat loss and predict quenching limit of flame in a down scaled combustor. Heat loss in the burned region is expressed in a convective form as a product of wall surface area, heat transfer coefficient and temperature difference. Comparison to the measurements showed satisfactory agreement of the pressure and temperature drop. Quenching is accounted for by introducing a correlation of quenching parameter and heat loss. The present model predicted burnt fraction of gases with reasonable accuracy and proved to be applicable in thermal design of a micro combustor.

Spray combustion with high temperature air in a Gas Turbine Combustor (가스터빈 연소기내의 고온공기 분무연소 해석)

  • Jo, Sang-Pil;Kim, Ho-Young;Park, Sim-Soo
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.192-198
    • /
    • 2004
  • A numerical study was conducted to determine the effects of high temperature air, including equivalent ratio on flow field, temperature, evaporation, and overall temperature distribution in gas turbine combustor. A sector model of a typical wall jet can combustor, featuring introduction of primary air and dilution air via wall jet, was used in calculations. Flow field and temperature distribution were analyzed. Operating conditions such as inlet temperature and overall equivalent ratio were varied from 373 to 1300 K, and from 0.3 to 0.6, respectively, while any other operating conditions were fixed. The RNG ${\kappa}-{\varepsilon}$ model and eddy breakup model were used for turbulence and combustion model respectively. It was found that the increase with the inlet air temperature, velocity in the combustor is accelerated and evaporation of liquid fuel is not affected in primary zone, high temperature inlet air enhances the evaporation and improves overall temperature distribution factor.

  • PDF