• 제목/요약/키워드: Mode of failure

검색결과 2,213건 처리시간 0.026초

앵커볼트의 내력평가에 관한 실험적 연구 (Strength of Anchors under Load Applied Angles)

  • 김성용;한덕전;신창훈
    • 한국방재학회 논문집
    • /
    • 제5권1호
    • /
    • pp.69-76
    • /
    • 2005
  • 본 연구는 익스팬션(고하중 앵커와 웨지앵커)의 내력평가 하기 위한 실험적 연구이다. 하중조건은 인발, 전단 및 인발과 전단의 조합하중이다. 고하중 앵커와 웨지 앵커는 국내산 앵커를 사용하였으며, 무근콘크리트에 매입하였다. 앵커 파괴 및 콘크리트 파괴모드에 따른 기존의 앵커 설계식를 연구하였으며, 실험결과를 인발 및 전단내력의 상호작용에 관한 여러 모델들과 비교 분석하였다. 연구결과 다음과 같은 결론을 얻었다. 조합하중 작용 시 힘의 상호작용은 타원형 상호관계가 가장 적합한 것으로 판단된다.

EPC method for delamination assessment of basalt FRP pipe: electrodes number effect

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제4권1호
    • /
    • pp.69-84
    • /
    • 2017
  • Delamination is the most common failure mode in layered composite materials. The author have found that the electrical potential change (EPC) technique using response surfaces method is very effective in assessment delamination in basalt fiber reinforced polymer (FRP) laminate composite pipe by using electrical capacitance sensor (ECS). In the present study, the effect of the electrodes number on the method is investigated using FEM analyses for delamination location/size detection by ANSYS and MATLAB, which are combined to simulate sensor characteristic. Three cases of electrodes number are analyzed here are eight, twelve and sixteen electrodes, afterwards, the delamination is introduced into between the three layers [$0^{\circ}/90^{\circ}/0^{\circ}$]s laminates pipe, split into eight, twelve and sixteen scenarios for cases of eight, twelve and sixteen electrodes respectively. Response surfaces are adopted as a tool for solving inverse problems to estimate delamination location/size from the measured EPC of all segments between electrodes. As a result, it was revealed that the estimation performances of delamination location/size depends on the electrodes number. For ECS, the high number of electrodes is required to obtain high estimation performances of delamination location/size. The illustrated results are in excellent agreement with solutions available in the literature, thus validating the accuracy and reliability of the proposed technique.

에너지 흡수효율에 의한 구조물간 내진 성능 비교 (Comparative Seismic Evaluation of Structures by Energy Absorption Efficiency)

  • 김장훈
    • 한국지진공학회논문집
    • /
    • 제5권3호
    • /
    • pp.37-43
    • /
    • 2001
  • 다양한 구조시스템간 반복하중에 대한 거동 성능을 비교하고자 에너지 개념을 확장하였다. 이로부터 에너지 흡수효율이 정의되었는데 이는 구조체의 누적에너지 흡수능력을 기준이 되는 탄성-완전소성시스템의 누적에너지 흠수량으로 나누어 무차원화한 것이다. 이를 위하여 반복하중실험으로부터 구한 실험결과들을 정리하여 에너지곡선의 형태로 표현하여야 한다. 제안된 방법을 이용하여 기하학적으로, 재료적으로 또한 구법이 서로 상이한 구조체간의 내진 성능에 대한 상대적이며 객관적인 비교가 가능해진다. 또한 이 방법의 가장 큰 장점 중의 하나는 구조물의 파괴형태와 관계없이 반복하중에 의한 힘-변위 관계만 주어지면 충분하다는 것이다. 제안된 방법을 두 시험체의 실험결과에 적용하여 그 타당성을 입증하여 보았다.

  • PDF

신형상 냉간성형 단면의 구조적 거동(II) - 휨거동 (Structural Behavior of Newly Developed Cold-Formed Steel Sections(II) - Flexural Behavior)

  • 송인섭;김갑득;권영봉
    • 한국강구조학회 논문집
    • /
    • 제14권2호
    • /
    • pp.357-364
    • /
    • 2002
  • 스터드, 조이스트 및 지붕 트러스에 적용하기 위한 폐단면 냉간성형부재의 휨실험을 수행하고 해석치와 비교하여 보았다. 길이 2.4m, 폭 0.9m의 휨 시편은 46cm 간격의 두 개의 강재보의 한면에 석고보드와 합판을 부착한 시편과 부착하지 않은 시편으로 구성되었고, 각 시편에 대한 정, 부모멘트실험을 수행하여, 강재보에 부착된 합판 및 석고보드가 강재의 좌굴거동에 미치는 영향을 포함한 합성거동을 파악하였다. 또한 합판이 부착된 실물 트러스 실험을 통하여 트러스 부재의 좌굴거동 및 파괴양상에 대하여 연구하였다.

중점 안전관리 항목 도출을 위한 FMEA활용 방안;철골 공사 사례를 중심으로 (A Study of FMEA for Selecting Priority Safety Unit;focusing on the cases of steel frame work)

  • 박찬종;송지원;유정호;김창덕
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2006년도 정기학술발표대회 논문집
    • /
    • pp.502-506
    • /
    • 2006
  • 건설재해는 반복재해가 빈번하게 일어나고 재해 발생 시 대부분이 중대재해이므로 안전관리에 더욱더 철저해야만 한다. 하지만 우리나라 건설 산업에서 안전관리 시스템은 관리기법이나 사고예방을 위한 구체적이고 기술적인 수단은 빈곤하며 단순하고 과학적이지 못하다. 이러한 건설 산업에서 안전관리 부분에서 FMEA를 이용하여 안전관리 중점대상 선정 및 중요도의 수치화를 통하여 안전관리 대상에 대한 관리 체계를 확립하기 위한 과학적이고 체계적인 방안에 대하여 연구하였으며 산업안전관리공단의 중대재해 사례를 통하여 실제 사례를 보여주었다.

  • PDF

가속 열 노화시험을 이용한 침매터널용 고무 씰 소재의 사용수명 예측 (Service life prediction of rubber seal materials for immersion tunnel by accelerated thermal degradation tests)

  • 박준형;박광화;박형근;권영일;김종호;성일경
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제9권4호
    • /
    • pp.275-290
    • /
    • 2009
  • This paper considers accelerated thermal degradation tests which are performed for rubber seal materials used for undersea tunnels constructed by immersion method. Three types of rubber seals are tested; rubber expansion seal, omega seal, and shock absorber hose. Main ingredient of rubber expansion seal is EPDM(Ethylene Propylene Diene Monomer) and that of both omega seal and shock absorber hose is SBR(Styrene Butadiene Rubber). The accelerated stress is temperature and an Arrhenius model is introduced to describe the relationship between the lifetime and the stress. From the accelerated degradation tests, dominant failure mode of the rubber seals is found to be the loss of elongation. The lifetime distribution and the service life of the rubber seals at use condition are estimated from the test results. The acceleration factor for three types of rubber seals are also investigated.

  • PDF

Strain distribution between CFRP strip and concrete at strengthened RC beam against shear

  • Anil, Ozgur;Bulut, Nalan;Ayhan, Murat
    • Structural Engineering and Mechanics
    • /
    • 제41권4호
    • /
    • pp.509-525
    • /
    • 2012
  • In recent years, CFRP material usage in strengthening applications gradually became widespread. Especially, the studies on the strengthening of shear deficient reinforced concrete beams with CFRP strips are chosen as a subject to numerous experimental studies and research on this subject are increased rapidly. The most important variable, that is affected on the failure mode of CFRP strips and that is needed for determining the shear capacity of the strengthened reinforced concrete beams, is the strain distribution between CFRP strips and concrete. Numerous experimental studies are encountered in the literature about the determination of strain distribution between CFRP strips and concrete. However, these studies mainly focused on the CFRP strips under axial tension. There are very limited numbers of experimental and analytic studies examining the strain distribution between concrete and CFRP strips, which are under combined stresses due to the effects of shear force and bending moment. For this reason, existing experimental study in the literature is used as model for ANSYS finite element software. Nonlinear finite element analysis of RC beams strengthened against shear with CFRP strips under reverse cyclic loading is performed. The strain distributions between CFRP strips and concrete that is obtained from finite element analysis are compared with the results of experimental measurements. It is seen that the experimental results are consisted with the results derived from the finite element analysis and important findings on the strain distribution profile are reached by obtaining strain values of many points using finite element method.

철도차량의 구매 요구사항에 포함되는 RAMS 특성값에 관한 연구 (A study on RAMS parameters in the Procurement requirement for rolling stock)

  • 정인수;김종운;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.780-788
    • /
    • 2008
  • As a railway is receiving attention as an environment-friendly transportation mode, many high speed, inter-city and urban railway are constructed and remodeled in the world. With this trend, railway RAMS was included in the international standard IEC 62278 in 2002. RAMS activity in domestic market is also increased with this international trend. However, IEC 62278 does not describe the methodology of substantial contents like how reliability target is set although it can be used as an overall guideline when RAMS requirements are included in the purchase specification. That is because RAMS requirements should be set with the specific railway condition. It is required to fully understand the meaning of railway RAMS parameters and apply those correspond to the specific railway system and environment condition especially when a quantitative RAMS requirement is set. In this study, the meaning and characteristics of RAMS parameters applicable to the development of quantitative RAMS requirement of rolling stock is described. And the basic concept of RAMS and the definition of failure that IEC 62278 describes is modified and suggested in order to make more suitable to the development of quantitative RAMS requirement.

  • PDF

지/단락실증시험에서 MW급 계통연계형 ESS 절연/보호시스템 성능 분석에 관한 연구 (Analysis on Insulation and Protection Characteristics of Grid Connected ESS in Ground/Short-Circuit Fault)

  • 김진태;이승용;박상진;차한주;김수열
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.119-122
    • /
    • 2020
  • With recent ESS (Energy Storage System) fire accident, the fault protection performance is becoming more important. However, there has never been any experiments with the protection performance on the faults in the ESS system level. In this study, the effect of AC ground fault and IGBT (Insulated Gate Bipolar mode Transistor) short-circuit failure on MW class ESS was performed experimentally for the first time in the world. First of all, the effect of the AC single line ground fault on battery was analyzed. Moreover, the transient voltage was investigated as a function of the battery capacity and the power level. Finally, the breaking capability and insulation performance of ESS were examined under PCS short-circuit fault condition. Through the tests, it was found that ESS protection system safely blocked the faulty current regardless of the faults, whereas the electronic parts such as IGBT and MC (Magnetic Contactor) were broken by the fault current. Also, the electrical breakdown in ESS resulted from the transient voltage during the protection process.

Experimental performance of Y-shaped eccentrically braced frames fabricated with high strength steel

  • Lian, Ming;Su, Mingzhou;Guo, Yan
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.441-453
    • /
    • 2017
  • In Y-shaped eccentrically braced frame fabricated with high strength steel (Y-HSS-EBF), link uses conventional steel while other structural members use high strength steel. Cyclic test for a 1:2 length scaled one-bay and one-story Y-HSS-EBF specimen and shake table test for a 1:2 length scaled three-story Y-HSS-EBF specimen were carried out to research the seismic performance of Y-HSS-EBF. These include the failure mode, load-bearing capacity, ductility, energy dissipation capacity, dynamic properties, acceleration responses, displacement responses, and dynamic strain responses. The test results indicated that the one-bay and one-story Y-HSS-EBF specimen had good load-bearing capacity and ductility capacity. The three-story specimen cumulative structural damage and deformation increased, while its stiffness decreased. There was no plastic deformation observed in the braces, beams, or columns in the three-story Y-HSS-EBF specimen, and there was no danger of collapse during the seismic loads. The designed shear link dissipated the energy via shear deformation during the seismic loads. When the specimen was fractured, the maximum link plastic rotation angle was higher than 0.08 rad for the shear link in AISC341-10. The Y-HSS-EBF is a safe dual system with reliable hysteretic behaviors and seismic performance.