• 제목/요약/키워드: Mode frequency

검색결과 4,294건 처리시간 0.039초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

휴대장치를 위한 응용프로그램 특성에 따른 적응형 전력관리 기법 (An Application-Specific and Adaptive Power Management Technique for Portable Systems)

  • 이강웅;이재진;신현식
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제34권8호
    • /
    • pp.367-376
    • /
    • 2007
  • 본 논문은 dynamic voltage scaling (DVS)를 지원하는 휴대장치를 대상으로 하여 응용프로그램 특성에 따라 실행 중에 전력관리 기법이 다르게 적용되는 적응형 전력관리 기법에 대하여 소개한다. 본 논문의 전력관리 기법은 멀티태스킹 시스템에서 실행되는 soft real-time 프로그램의 memory subsystem 과 프로세서의 실행 시간(run time) 및 유휴 시간(idle time)을 고려하여 프로그램 실행 중에 최적의 DVS가 적용될 수 있도록 하여 전력을 관리한다. 세부적인 전력 및 실행시간 프로파일 정보를 이용할 수 있도록 adaptive power manager(APM)를 개발하여 운영체제에 연동시켰고, Post-pass 최적화기는 APM을 위한 적응형 API를 프로그램의 실행이미지에 삽입하여 실행 중 DVS가 적용되는 코드영역을 표시한다. APM은 프로그램 실행 중에 cache miss 수 등을 측정하는 CPU의 pertormance counter들을 관찰한다. Performance counter들의 값을 바탕으로 CPU와 memory 중심의 코드 영역을 구분하여 프로세서의 유휴 시간에 대한 분석을 수행하고, 표시된 코드영역들에 대한 최적정 전압과 동작 클락을 결정하여 시스템에 반영한다. 제안하는 기법의 효과를 보이기 위하여 Intel의 XScale 프로세서 상에서 동작하는 Windows CE에 본 기법을 구현하였고, 실험을 통하여 본 논문에서 제시하는 기법이 영상이나 음성 데이타를 해독하는 프로그램과 같이 정기적으로 비슷한 일을 수행하는 프로그램에서 효과적임을 알 수 있었다. 실험 결과 본 기법으로 유휴시간에 프로세서를 저전력모드로 바꾸는 기존의 고전적인 전력 관리 기법보다 전체 시스템 전력 소모를 9% 더 절약할 수 있었다. 위성영상과 DEM 개발기술이 87% 이상의 점수를 받아 가장 시장성 및 활용성이 높은 기술로 평가되었으며, 초다분광영상에 대한 기술은 70%를 겨우 넘는 수준에서 평가가 되었다. 멀티센서 공간영상정보 통합처리 기술 개발은 다목적 실용위성의 보유, 국가 NGIS 사업의 결과물이 상당히 축척이 되어 있고, 라이다(LiDAR) 기술의 도입을 위한 환경이 조성되었기에 다른 국가에 비해 멀티센서 기술의 적용과 산업화가 가시화 될 수 있을 것으로 기대된다. 그러나 멀티센서 자료의 수급이 용이하지 못하고, 법 제도적인 한계, 시장의 성숙도가 기대이하라는 점 등의 한계를 노정하고 있다.a var. sieboldii 3. Pinus densiflora, Q. aliena, Q. acutissima, P. thunbergii, Q. acuta 4. Carpinus laxiflora, Camellia japonicas. C. tschonoskii community의 5개 그룹으로 나타났다. 하류의 부착돌말류는 상대적으로 양호한 수질을 가지고 있는 정점 1에서 다양한 생물상을, 탄천의 영향을 받는 정점 2는 상대적으로 수질이 악화되어 호오염성 종들이 높은 분포를 나타내고 있었다. 또한 부착돌말류 중 Cymbella minuta는 다른 부착돌말류에 비해 강한 오염지표성을 나타내고 있었다.p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). 골전이 병소의 발생부위는 척추골이 가장 많았으며, 골반골, 늑골, 두개골, 흉골, 견갑골, 대퇴골, 쇄골, 상완골 순서였다. 두개골 전이병소에 SUVmax가 가장 높은 값을 나타내었으며, 늑골의 SUVrel가 가장 높은 값을 나타내었다. 경화성 골전이 병소가 다른 형태의 골전이

난임여성의 정서적 특성에 따른 산림치유 프로그램 요구 분석 (Analysis of Forest Therapy Program Needs according to Emotional Characteristics of Subfertile Women)

  • 부서윤;신창섭
    • 한국환경생태학회지
    • /
    • 제34권1호
    • /
    • pp.72-84
    • /
    • 2020
  • 본 연구의 목적은 난임 여성을 위한 산림치유 프로그램 개발의 기초자료를 제공하는 데 있다. 본 연구는 탐색적 연구로 난임 여성의 정서적 특성과 정서적 특성에 따른 산림치유 요구도가 무엇인지 밝혀내어 산림치유 프로그램 개발과 운영을 위한 기초 자료를 제공할 것이다. 본 연구는 서울 소재 난임 전문병원에 내왕하는 난임 여성 200명을 대상으로 난임 여성의 정서적 특성과 산림치유 프로그램 요구도에 대한 33항목을 설문한 조사연구이다. 자료 분석은 SPSS 21.0 프로그램을 이용하여 난임여성의 정서적 특성과 산림치유 프로그램에 대한 요구 사이의 상관관계와 중요도를 파악하고자 빈도분석과 교차분석, 일원분산분석을 진행하였다. 난임 여성들의 정서적 특성은 임신에 대한 압박감, 불안 및 두려움, 우울, 절망감, 무기력, 외로움, 슬픔, 수치심 및 죄책감, 조급함과 답답함, 분노 및 과민함 등으로 나타났다. 난임 여성의 임신에 대한 압박감, 우울, 절망감, 무기력, 외로움, 슬픔과 분노와 과민함, 불안 및 두려움이 높게 나타났다. 난임 여성의 정서적 특성에 따른 산림치유 프로그램 요구도 차이를 알 수 있었다. 임신에 대한 압박감과 수치심 및 죄책감에 따라서 난임 부부 산림치유 프로그램의 운영 형태가 유의한 차이가 있는 것으로 나타났다. 불안과 두려움에 따라서 프로그램 참여 경험이 유의한 차이가 나타났고, 우울, 절망감, 무기력, 외로움, 슬픔에 따라서는 산림치유 프로그램에 참여하지 못하는 이유에 유의한 차이가 있는 것으로 나타났다. 조급함과 답답함에 따라서는 희망하는 산림치유 프로그램 동반 참여자에 대해 유의한 차이가 있는 것으로 나타났다. 분노와 과민함에 따라서 산림치유 프로그램 참여경험 및 난임 여성을 위한 산림치유 프로그램을 통한 자조모임의 효과에 대해 유의한 차이가 있는 것으로 나타났다. 본 연구의 분석 결과가 난임 여성의 심신건강 증진을 위한 산림치유 프로그램을 개발하는 데 기초자료로 활용되기를 기대한다.

신안군(新安郡) 낙도(落島)에서 발생(發生)한 괴질(怪疾)의 원인(原因)에 관한 역학적(疫學的) 조사(調査)(I) (Epidemiologic Investigation for the Etiology of an Epidemic Ocurred among Animals and Humans in an Isolated Island, Korea(I))

  • 김정순;허용;윤형렬;이원영
    • Journal of Preventive Medicine and Public Health
    • /
    • 제22권2호
    • /
    • pp.290-301
    • /
    • 1989
  • This is preliminary report on anthrax epidemic occurred in an island with about 100 residents. Since 1982 there had been sudden deaths among all kinds of domestic animals including cattle, dogs, ducks, chicken and goat but only a few among cats in an isolated island about three hours distance away by ferry boat from Mokpo city. From 1986 through 1988 nine human deaths and four patients occurred, which made the government intervene for investigation on June 25 1988. The epidemiological investigation consisted of interview survey and medical examination, medical record analysis, laboratory work to isolate the pathogens under the direction of hypothesis derived from the study and further confirmation of the pathogens by international institute. The summarized results are as followings: 1. According to the interview survey there were many deaths among domestic animals usually in cold and dry season such as January through March and September through November; 36 heads of cattle leaving one head, more than 40 hogs(all), hundreds of chicken leaving few alive, goats that had taken home from mountain and two or three cats out of around 40 had sudden deaths from 1982 till 1985, when the residents stopped to purchase and take them into the island anymore. Also there were eleven persons who had experienced the similar syndrome complex to those of admitted and expired patients and four of them revealed typical chest X-ray findings; from one of these four patients(Rho) B. anthracis is isolated. 2. Medical record on patients who had been admitted, showed common characteristics of the disease course. On admission they had either gastrointestinal or upper respiratory infection symptoms which invariably progressed to septicemic nature with pulmonary interstitial infiltration and mediastinal widening/bulging, and then to deadly acute respiratory distress syndrome. At the end stage chest X-ray revealed multiple bullous emphysema. One of another characteristics was oral ulceration with bleeding occurred in about 50% of the patients. Laboratory test results in common were leukocytosis with left shift and abnormal liver and kidney functions, particularly at the later stage of the illness. 3. Epidemiological characteristics was striking in that both mortality and incidence rates were high: the mortality rate was 8.7% average, male being three times higher than females but there was no distictive clustering by age group. The incidence rate for both sexes was 28.2% and there was no sex difference although a tendency of higher incidence among older ages was noticed. The highest mortality and incidence were observed in Won village where the first death of animal occurred and with the highest frequency among three villages of the island. 4. Among twelve bacilli species isolated from various specimens, two strains, one from patient and the other from soil where the recently died cow is hurried, were confirmed as B. anthracis by Pasteur Institute and CDC of USA(strain from soil). CDC reported that the strain did not produce capsule in bicarbonate media but reacted with the bacteriophage and one of five sera taken from the patients. Mode of transmission as well as incubation period of the agent has not been established yet, which needs further investigation in relation to the antigenic structure of the variant when it is confirmed.

  • PDF

소비자의 라이프스타일에 따른 서비스품질 지각 차이에 관한 연구 (A Study on the Consumer's Service Quality Perception Based on the Types of Life-style)

  • 박윤서;이승인;최인
    • 마케팅과학연구
    • /
    • 제19권2호
    • /
    • pp.53-67
    • /
    • 2009
  • For the last decades, service quality has been studied as one of the most important tools for a service company to compete with the other companies. Based on these past researches, it has been agreed that the service quality is a basic and powerful tool to create the competitive advantage. Due to similar reason, many service marketing practitioners have been also focused on the service quality to retain the existing consumers and collect the new consumers. However, service quality is subjectively perceived by individual consumers. Consumer evaluation of service quality can be different from each other. Especially consumers with one life-style may evaluate the service quality differently from the consumers with the other life-styles. Therefore we need to know whether there are differences in service quality perception on the categories of life-style. Life-style refers to a distinctive mode of living in its aggregate and broadest sense. It embodies the patterns that were developed and emerged from the dynamics of living in a society. Since the concept of life-style and its relationship to marketing was introduced in 1963 by William Lazer, methods of measuring the life-style and their application have been developed. Life-style has been usually used to segment the marketplace because it offers marketers a unique and important view of the market. When Life-style is combined with clustering methods, life-style segmentation can generate identifiable whole persons rather than isolated fragment. Life-style segmentation begins with people instead of products and classifies them into different life-style types, each characterized by a unique style of living based on a wide range of activities, interests, and opinions(Plummer, 1974). In this study we applies the life-style segmentation based on the AIO(Activities, Interests, and Opinions) to the consumers of the large discount stores. In Korea, the large discount store market has entered into maturity stage so that the market differentiation strategy is becoming a more critical issue to the marketing practitioners. One of the most important tools to differentiate from the competitors in large discount store market is continuously to provide service of better quality than competitors. This study tries to find answers about the following questions: 1) How can we categorize the consumer life-styles in the large discount store? 2) What are the characteristics of the categorized groups? 3) Are there any differences in service quality perception among the consumers with different life-styles 4) Are there any differences in consumer behavior among them in the large discount store? For the purpose, we collected survey data from consumers and analyzed the data with the SPSS package where we had $X^2$-test, factor analysis, ANOVA, MANOVA, and cluster analysis. The survey was made during one month in the April of 2008. Among the collected 306 copies of questionnaires, 281 copies were chosen as the effective samples for empirical analysis except 25 copies with wrong responses. To identify the life-style patterns, we used the measures employed by Kim and Kwon(1999), where 44 items on a seven-point scale were used to measure factors of the life-style patterns. The Principal Component Method was used for factor extraction, and the VARIMAX orthogonal factor rotation was employed. The 7 items showing low factor loading were eliminated. The results of the factor analysis suggested that nine factors of the life-style patterns were identified as follows: 1) the equality-of-sexes and pursuit-of-independence tendency 2) self-management tendency 3) sociable tendency 4) self-display tendency 5) degree of a dilettante life 6) pursuit-of-information tendency 7) bargain hunter tendency 8) TV preference tendency 9) pursuit-of-leisure tendency. Next, after the K-means cluster analysis was performed with nine factors of the life-style patterns, the life-styles of the respondents were classified into four groups which are named as the 'progressive practicality-oriented group', 'positive success-oriented group', 'sociable ostentation-oriented group', 'stable conservation-oriented group'. The analysis results for usage behavior between the market segments showed statistically significant differences in the frequency of usage, duration time in the store, consumer satisfaction, and loyalty. Also, we tried to investigate whether the large discount store consumers differently perceive the quality of service based upon the types of life-style. To measure the service quality of large discount store, we adapted several measurement models measuring the service quality such as SERVPERF, BCP, R-SERVPERF, R-BCP. MANOVA and One-Way ANOVA were performed to confirm the difference in service quality perception based on the market segments. The results have also shown significant differences between life-style types in service quality perception. These findings show that the large discount store marketers should consider consumer life-style as one of the most important market segments for marketing and understand the difference in service quality perception between life-style types. Our findings give important implications to marketers of large discount stores as well as life-style researchers. First, this study showed there were significant differences in consumer's service quality perception and usage behavior between the types of life-style. It provides evidence that the life-style approach can be a important basis in segmenting the large discount store market and will make consumers perceive the service quality high. Second, most previous researches on service quality have been in aggregate level. However, our results imply that the future research on service quality have to focus on segment level.

  • PDF

소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 - (Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography -)

  • 이희정;손순룡;이원홍
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권4호
    • /
    • pp.279-286
    • /
    • 2005
  • 목 적 : 소장조영술과 복부골반 CT검사의 진단 결과를 비교함으로써 방사선학적 영상의 특징 파악 및 질환에 따른 적절한 방사선학적 검사법을 선택하는데 기초자료를 제공하고자 한다. 대상 및 방법 : 1999년부터 2000년까지 소장조영술과 복부골반 CT검사를 병행하여 시행한 환자 284명을 대상으로 하여, 각각의 진단 소견을 병명별로 분류하였다. 소장조영술은 250 ml 황산바륨 현탁액(W/V 40W/V%, Methylcellulose+$BaSo_4$)을 경구로 복용시키고, Rt. recumbent position을 취하게 한 후 약 10분 후에 Carboxymethylcellulose solution(0.5%) 600 ml 복용시켰다. 20분, 40분, 1시간 정규촬영을 하고, 조영제가 회맹판(I-C valve)을 통과하면 투시 하에 저격촬영을 시행하였다. 복부골반전산화단층촬영은 검사 1시간 전에 $BaSO_4$+Methylcellulose 1.5 W/V% 450 ml를 복용시키고 검사직전 450 ml 추가로 복용시켰다. 요오드 성분의 비이온성 조영제 2.5 ml flow/sec로 주입하고, 조영제 주입 후 72초 지연 촬영을 하였다. 촬영은 간 상연에서부터 치골결합 부위까지 continuous scan을 시행하였으며, 검사 protocol은 Helical thick 5 mm, picth 1.375 : 1, speed 27.50, increment 5 mm, 120 kV, 245 mA로 하였다. 결 과 : 소장조영술에서는 정상(Normal)이 131예(46.1%), 감염성 장질환(Inflammatory bowel disease ; 이하 IBS)이 65예(22.9%), ischemia+ileocolitis+vasculitis 22예(7.7%), obstruction+stricture 21예(7.4%)의 순으로 나타났고, 복부골반 CT검사에서는 정상이 103예(36.3%) IBS가 65예(22.9%), wall thickening+lymphadenopathy가 42예(14.8%), fluid collection이 17예(6%)의 순으로 나타났다. 소장조영술과 복부골반 CT검사에서 동일하지 않은 결과로 진단된 경우는 소장조영술에서 정상으로 진단된 132명(46.1%) 중 14예(10.6%), 복부골반 CT검사 결과에서는 wall thickening+lymphadenopathy와 IBS로 진단되어 차이를 보였으며, 복부골반 CT검사 결과 정상으로 진단된 103예(36.3%) 중 5예(5.8%)가 소장조영술에서 ischemia+ileocolitis+vasculitis로 진단되었다. 정상으로 진단 된 235예 중 37예(15.9%)가 서로 다른 결과로 진단되어 통계적으로 유의한 차이를 보였다(P<0.05). 결 론 : 본 연구에서 특정질환에 특정검사의 진단결과가 우수하게 나타나는 것으로 조사되었으므로 방사선학적 검사의 진단적 민감도를 높이기 위해서는 처방 및 검사에 있어서 질환에 따른 적절한 검사법의 선택이 무엇보다도 중요하리라 사료된다.

  • PDF

접착제의 종류에 따른 침식치아에 대한 복합레진의 결합강도 (COMPARISON OF MICROTENSILE BOND STRENGTH OF COMPOSITE RESTORATION TO ERODED ENAMEL BY SURFACE TREATMENT)

  • 이순영;이경호;노홍석;정태성;김신
    • 대한소아치과학회지
    • /
    • 제38권4호
    • /
    • pp.348-354
    • /
    • 2011
  • 침식 법랑질의 표층은 건전 법랑질과는 물리화학적 성상이 다르므로 침식 법랑질면에 대한 복합레진의 결합력을 증가시키기 위한 대안으로, 법랑질 내층으로의 침투력이 탁월한 infiltrant resin을 응용하는 방법을 생각하게 되었다. 본 연구는 다양한 정도로 인공 침식이 유발된 법랑질면을 대상으로, infiltrant resin과/또는 기존의 접착제를 적용한 경우의 복합레진 결합강도를 비교 분석할 목적으로 시도되었다. 건전한 순면을 가진 발거된 상악 유전치를 대상으로, 인공침식 유발 횟수 및 infiltrant resin과/또는 기존의 접착제를 적용한 방법에 따라 각 20개씩의 시료를 제작하였으며, 각 군의 미세인장 결합강도를 측정하고, 파절면의 파절 양상을 평가하여 다음과 같은 결과를 얻었다. 법랑질 표면의 침식 유발 횟수가 늘어날수록 결합강도가 낮았다(p<0.05). 기존의 접착제 상부에 infiltrant resin을 추가 적용한 군, infiltrant resin만 적용한 군, 접착제만 적용한 군의 순으로 미세인장결합강도가 높게 나타났다(p<0.05). 파절 양상의 관찰에서는 인공 침식 유발 횟수가 적은 군 및 infiltrant resin을 적용한 군에서 응집파절의 비율이 높게 나타났다. 결론적으로, 법랑질의 침식도가 클수록 복합레진 수복물과의 결합 강도는 감소하였으며, infiltrant resin으로 기존의 적찹제를 대체하거나 첨가함으로써 결합강도를 보완시킬 수 있을 것으로 판단되었다.

비글견에 있어서 간, 신장 및 비장의 초음파 히스토그램 비교 (Comparison of Ultrasound Histogram in Liver, Kidney and Spleen in Beagle Dogs)

  • 이기창;정주현;오선경;정유철;임창윤;윤정희;최민철
    • 한국임상수의학회지
    • /
    • 제22권3호
    • /
    • pp.186-189
    • /
    • 2005
  • 초음파 히스토그램의 내부 장기에 대한 임상적용을 알아보기 위하여 다주파수 탐촉자의 초음파기기를 이용하여 실험하였다. 9마리의 정상 비글견을 우측전복부의 간과 우측신장, 좌측전복부의 간, 비장과 신장를 검사하였다. 같은 깊이의 B-모드 영상으로 간, 신장의 피질, 비장, 그리고 각 신장의 피질과 수질의 수치를 비교하였다. 우측신장피질의 메아리발생치는 간에 비하여 유의적으로 $15{\%}$ 낮았다. 비장의 메아리발생치는 좌측신장피질보다 $23{\%}$ 높았으며, 간은 좌측 신장피질보다 $30{\%}$ 높았다. 각 신장의 피질과 수질의 비교에서는 피질이 우측과 좌측에서 각각 $47{\%}$$65{\%}$ 높게 나타났다(P<0.05). 우측신장피질과 간실질간의 메아리발생치 비율은 $0.86{\pm}0.11$, 비장과 좌측신장간에는 $1.37{\pm}0.47$, 간실질과 좌측신장피질간에는 $1.30{\pm}0.19$이었으며, 이들 모두다 유의적인 차이가 있었다(p<0.05). 초음파 히스토그램은 간, 비장, 신장 같은 내장장기의 구조물의 초음파적 평가에서 정량적으로 평가하기에 단순하고 유용하고 실질적이다.

무안지역 메탄가스의 단주기적 농도변화에 대한 평가 (Studies of Short-Term Variability of Methane in the Moo-Ahn Observatory Site in Korea)

  • 최규훈;윤용훈;김창희;조영민;김기현
    • 한국지구과학회지
    • /
    • 제22권4호
    • /
    • pp.327-338
    • /
    • 2001
  • 본 연구에서는 전남 무안지역을 중심으로 관측한 농도자료와 세계의 주요 배경관측지점인 Point Barrow(Alaska), Mauna Loa(Hawaii)를 중심으로 관측한 농도자료를 이용하여, 메탄의 농도분포특성을 지역 또는 시간의 함수로 비교분석하였다. 이들 관측점들은 주요 위도대를 대표하기 때문에, 위도별 베탄의 분포특성을 파악하는데도 중요한 단서를 제공하였다. 또한 본 연구결과에 기초하여 메탄의 농도변화양상을 여러 가지 시간적 주기로 비교하고, 그러한 결과의 의미를 다양한 통계적 기법에 기초하여 분석하였다. 전체 관측기간동안 확보된 일평균 농도자료로부터 계산된 무안지역의 농도는 1898${\pm}$85.3ppb(N=812)로 나타났다. 동일한 기관동안 두 개의 비교관측지점인 Point Barrow와 Mauna Loa 지역에서는 1832${\pm}$29.6ppb(N=823), 1745${\pm}$14.8ppb(N=818)의 평균농도가 각각 관측되었다. 각 지점에서 관측된 자료를 이용하여 빈도분포를 비교한 결과에 따르면, 무안지역에서 1900ppb의 최빈값을 나타낸 반면, Point Barrow, Mauna Loa 지역에서는 각각 1850, 1750ppb로 (상대적으로) 낮은 최빈값을 보여주었다. 이 논문에서는 국내의 관측점에서 발견되는 고농도의 메탄분포특성을 여러 관점에서 비교하고 해석하고자 하였다. 국외지역에서 주로 발견되는 미미한 수준의 농도변화 경향과 달리, 무안지역에서는 여타 지역들에 비해 절대적으로 높은 농도값이 유지되고 그 농도변화가 주야간대별로 뚜렷하게 구분될 정도로 주기적인 변화의 폭이 큰 것으로 확인되었다. 특히 무안지역에서는 낮시간대(6:00 AM 이후)에 농도가 낮아지고, 저녁시간대에 농도치가 상승하는 경향이 두드러졌다. 풍향과 CH$_4$농도관계를 비교한 결과, 연구대상지역이 서해안에 위치한 지리적인 요건으로 인해 상대적으로 청정한 해풍이 주를 이루는 서풍계열의 풍계가 나타날 때, CH$_4$의 농도는 낮은 수준을 유지하는 것으로 나타났다. 본 연구에 의하면, 국내 지점의 메탄농도는 국외여타 지점에 비해 뚜렷하게 구분이 될 정도로 높은 수준을 유지하고 있다. 이러한 현상을 초래하는 원인으로 여타 비교대상지역들에 비해, 무안지역이 보다 다양한 배출원의 영향에 직접적으로 노출된데 따른 영향을 직간접적으로 반영하는 결과로 사료된다. 연구지점에서 발견된 CH$_4$의 고농도 현상과 일주기를 중심으로 반복되는 농도의 큰 진동폭이 나타나는 현상도 역시 주목할 만하다.

  • PDF

산 처리가 상아질 접착에 미치는 영향 (EFFECT OF ACID-TREATMENT ON DENTIN BONDING)

  • 김영경;김성교;박진훈
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.73-83
    • /
    • 1993
  • 산 처리방법에 따른 상아질 접착을 평가하고 표면처리 후의 상아질 표면의 성상변화 및 파단면의 양상을 관찰하기 위해 발거된 구치 에 10% polyacrylic acid (GC Dental Industrial Corp., U. S. A.), 10 % 인산(Bisco Inc., U. S. A.) 및 10-3 용액 (Parkell Bio-Materials, U. S. A.)을 사용하여 상아질 표면을 처리하고 모든 시편에 상아질 접착제인 All Bond 2$^{(R)}$(Bisco Inc., U.S.A.)를 도포하였으며 복합레진 (Silux Plus$^{(R)}$, 3M Co., U.S.A.)을 첨가한 후 접착강도를 측정하고 상아질 표면 및 파단면을 주사 전자현미경으로 관찰, 비교하여 다음과 같은 결과를 얻었다. 1. 접착강도는 상아질 표면을 산 처리한 군이 무처리한 대조군에 비해 높게 나타났고, 산처리를 시행한 군들 간에는 10-3 용액으로 처리한 군이 가장 높았으며 10% 인산으로 처리한 군, 10% polyacrylic acid로 처리한 군의 순이었다(p<0.01). 2. 상아질 표면의 관찰에서, 무 처리의 상아질 면은 상아세관이 개방되지 않은 채 도말층으로 덮혀 있었고, 10% polyacrylic acid로 처리한 상아질 면은 도말충이 제거되고 상아세관이 개방되어 있었으나 상아세관 내에 smear plug이 일부 남아 있었으며, 10% 인산또는 10-3 용액으로 처리한 상아질 면은 도말층 및 smear plug이 모두 제거되고 상아세관이 완전히 개방되어 있음이 관찰되었다. 3. 파단면의 관찰에서, 무 처리군에서는 도말층 내에서 파단이 일어났으며, 10% polyacrylic acid로 처리한 군에서는 상아세관 내 잔존 레진 tag이 관찰되지 않았으나 10% 인산 및 10-3 용액으로 처리한 군에서는 상아세관 내의 잔존 레진 tag이 관찰되었다. 4. 파단 양상에 있어서, 접착강도가 큰 군일수록 응집성 파단의 빈도가 증가되어 나타났으며, 각 시편에서 구한 접착강도와 응집 파단율의 상관 계수는 0.71이었다.

  • PDF