• Title/Summary/Keyword: Mode Switching

Search Result 1,343, Processing Time 0.027 seconds

A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation (절연형 고효율 PFC AC-DC 컨버터에 관한 연구)

  • Kwak, Dong-Kurl;Kim, Sang-Roan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.

Soft-Switching Buck Converter Dropped Voltage Stress of a free-Wheeling Diode Using a Single Switching Device (단일 스위칭소자를 이용하여 환류다이오드의 전압스트레스를 강하시킨 소프트-스위칭 벅 컨버터)

  • 이건행;김영석;김명오
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.9
    • /
    • pp.576-583
    • /
    • 2004
  • This paper presents a buck circuit topology of high-frequency with a single switching device. It solved the problem which arised from hard-switching in high-frequency using a resonant snubber and operating under the principle of ZCS turn-on and ZVS turn-off commutation schemes. In the existing circuit, it has the voltage stress that is almost twice of input voltage in a free-wheeling diode. In the proposed circuit, it has the voltage stress that is lower than input voltage with modifing a location of free -wheeling diode. In this paper, it expained the circuit operation of each mode and analyzed feedback-loop stabilization. Also it confirmed the waveform of each mode with simulation result. The experiment result verified the simulation waveform and compared the voltage stress of a free -wheeling diode in the exsiting circuit with the voltage stress of that in the proposed circuit. Moreover, it compares and analyzes the proposed circuit's efficiency with the hard-switching circuit's efficiency according to the change of load current.

Study on In-Plane Switching mode with discotic compensation film (Discotic 필름 보상형 In-Plane Switching 모드에 관한 연구)

  • Song, I.S.;Baik, I.S.;Jung, B.S.;Jeon, Y.M.;Lee, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.518-521
    • /
    • 2004
  • We have investigated about compensation film to reduce the light leakage at an oblique angle in-plane switching mode. It is well known that uncompensated in-plane switching (US) and fringe field switching (FFS) liquid crystal displays (LCDs) have much better viewing angle than other modes owing to the in-plane rotation of the LC director. However, to accomplish optimal viewing angle characteristics in these devices, they must be compensated by one or more films. So, in this paper, we have studied how to reduce the light leakage with viewing angle using discotic film in dark state.

  • PDF

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

An Optimal Determination of Subband-Frame Size and Mode Switching Level for Adaptive OFDM-TDD System (시분할 듀플렉싱 기반의 적응 직교 주파수 분할 다중 접속 시스템에서 부대역-프레임 크기와 모드 변환점의 최적 결정 기법)

  • Shin Kil-Ho;Lee Chang-Suk;Kim Jung-Gon;Kim Hyung-Myung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.512-522
    • /
    • 2005
  • In this paper, an optimal determination method of the subband-frame size and mode-switching level is proposed for adaptive OFDM-TDD systems in frequency-selective time-varying channels. The optimization problem considering frequency selectivity. user's mobility, and the signaling overhead caused by the mode change information is formulated in the maximum spectral efficiency sense satisfying the target BER. Assuming that subband-frame size is given, the mode-switching level is first optimized so that the spectral efficiency can be maximized satisfying the target BER. The subband-frame size among candidates is then determined, which maximizes the spectral efficiency. Simulation results show that the proposed scheme outperforms conventional schemes, in terms of the spectral efficiency and the BER.

Variable Structure Control Design Based on Eigenvalues Assignment of Sliding Mode (슬라이딩 모드 고유치 설정에 기반을 둔 가변구조 제어 설계)

  • Hong, Yeon-Chan;Lee, Tae-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.2207-2213
    • /
    • 2010
  • A new scheme for variable structure control design which is based on eigenvalues assignment of sliding mode is developed. In conventional methods, generally, specific type of system matrix like canonical or regular form is required to construct a switching surface. Furthermore, the methods are not explicit. The new method in this paper solved the problems. No special type of system matrix is required and very explicit. It is shown that the switching surface can be constructed and determined uniquely without any dependency on the system form. The proposed method is based on the fact that the dynamics of sliding mode is determined by system zeros. Finally, a numerical example is given to verify the validity of the results studied in this paper.

Design and Evaluation of Cascode GaN FET for Switching Power Conversion Systems

  • Jung, Dong Yun;Park, Youngrak;Lee, Hyun Soo;Jun, Chi Hoon;Jang, Hyun Gyu;Park, Junbo;Kim, Minki;Ko, Sang Choon;Nam, Eun Soo
    • ETRI Journal
    • /
    • v.39 no.1
    • /
    • pp.62-68
    • /
    • 2017
  • In this paper, we present the design and characterization analysis of a cascode GaN field-effect transistor (FET) for switching power conversion systems. To enable normally-off operation, a cascode GaN FET employs a low breakdown voltage (BV) enhancement-mode Si metal-oxide-semiconductor FET and a high-BV depletion-mode (D-mode) GaN FET. This paper demonstrates a normally-on D-mode GaN FET with high power density and high switching frequency, and presents a theoretical analysis of a hybrid cascode GaN FET design. A TO-254 packaged FET provides a drain current of 6.04 A at a drain voltage of 2 V, a BV of 520 V at a drain leakage current of $250{\mu}A$, and an on-resistance of $331m{\Omega}$. Finally, a boost converter is used to evaluate the performance of the cascode GaN FET in power conversion applications.

A Simple Resonant DC Link Snubber-Assisted Bi-directional Three-phase PWM Converter for Battery Energy Storage Systems

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.133-139
    • /
    • 2002
  • In this paper, a prototype of an active auxiliary quasi-resonant DC link (QRDCL) snubber assisted voltage source bidirectional power converter (AC to DC and DC to AC) operating at zero voltage soft-switching (BVS) PWM nlode is presented for a Battery Energy Storage System (BESS). The operating principle of this QRDCL circuit and multifunctional control-based converter system, including PWM inverter mode in which energy flows from the battery bank to the three-phase utility-grid in addition to an active PWM converter mode in which energy flows from the utility-grid to the battery banks are described respectively by the control implementation on the basis of d-q coordinate plane transformation. The multifunctional operation characteristics of this three-phase ZVS PWM bi-directional converter with QRDCL is demonstrated fer a BESS under the power conditioning and processing schemes of energy supply mode and energy storage mode, and compared with a conventional three-phase hard switching PWM bi-directional converter for a BESS. The effectiveness of the three-phase ZVS PWM hi-directional converter with QRDCL is proven via the simulation analysis.

Identification of Excitation System Model Parameters from the Test of Switching from MVR Mode to AVR Mode (MVR모드에서 AVR모드로의 절환에 의한 여자계 모델정수 결정)

  • Kim, Dong-Joon;Moon, Yung-Hwan;Choi, Kyung-Sun;Lyu, Seung-Hhon;Song, Seok-Ha;Lee, Heung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.91-94
    • /
    • 1996
  • A simulation procedure was developed for identifying Yungnam unit 2 excitation model parameters to improve the accuracy of stability simulation of KEPCO. First, generator model parameters are derived by using modified load rejection technique from measured load rejection test. For identifying excitation model parameters, switch was changed from MVR mode to AVR mode in Yungnam unit 2 excitation system instead of applying to a small step to the voltage reference($V_{ref}$) because of saving time and efforts, assuming the test result would show coincided result with applying to a small step to the $V_{ref}$. However, it was found that the response of switching from MVR to AVR is greatly different from it of applying small signal to the $V_{ref}$. A simulation procedure was needed to take into accounts of real AVR component status before and after switching from MVR to AVR. This paper reports the procedure which duplicated the measured response and addresses the merits of this test on conventional AVR step test.

  • PDF

Improvement of Dynamic Response for IPMSM based on DTC-CFTC Using Sliding Mode Control (일정 스위칭 주파수를 가지는 DTC 기반 IPMSM의 슬라이딩 모드 제어를 이용한 속응성 향상)

  • Han, Byeol;Bak, Yeongsu;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.628-635
    • /
    • 2019
  • This paper proposes sliding mode control (SMC) method for improvement of dynamic response for IPMSM based on DTC with constant switching frequency. DTC with constant switching frequency method consists of PI torque controller and triangular comparator for constant torque error status. It has the poor dynamic response compared to conventional DTC. This paper proposes improvement method of dynamic response of DTC with constant switching frequency by using SMC. Simulation results confirm the effectiveness of the proposed method.