• Title/Summary/Keyword: Mode Size

Search Result 1,741, Processing Time 0.036 seconds

A Study on Property Distribution of [011] Poled Mn:PIN-PMN-PT Single Crystals Grown by Bridgeman Method (Bridgeman 성장 [011] 분극 Mn:PIN-PMN-PT 압전단결정의 물성 분포 연구)

  • Soohyun Lim;Yub Je;Yohan Cho;Sang-Goo Lee;Hee-Seon Seo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.4
    • /
    • pp.412-419
    • /
    • 2024
  • Mn-doped Pb(In1/2Nb1/2)O3-Pb(Mg2/3Nb1/3)O3-PbTiO3 (Mn:PIN-PMN-PT) single crystals, which exhibit improved phase transition temperatures and coercive field properties compared to Pb(In1/2Nb1/2)O3-Pb(Mg2/3Nb1/3)O3-PbTiO3 (PIN-PMN-PT) single crystals, are expected to be utilized in high-power acoustic transducers. Bridgeman method, growing single crystals along the axial direction from melt, is most widely used method for single crystal growth with large size and high quality. However, single crystal boules grown by the Bridgeman method demonstrate a PT compositional variation, giving rise a distribution of crystal structure and material properties along the growing axis. To employ piezoelectric single crystals grown by the Bridgeman method for acoustic transducers, it is essential to investigate their overall property distribution. In this study, the compositional distribution and property variation of Mn:PIN-PMN-PT single crystals grown by the Bridgeman method was investigated. Measured compositional distribution of PT was from 29% to 32.5% in the Rhombohedral crystal region of the boule. Two types of specimen, [011]-poled Mn:PIN-PMN-29PT and Mn:PIN-PMN-32PT single crystals, were fabricated and tested to obtain full property variation at both ends of the Rhombohedral crystal region. The properties related to the 32 directional vibration mode and the properties related to high-power driving were measured to confirm the overall distribution of properties by composition.

Atomic Layer Deposition Method for Polymeric Optical Waveguide Fabrication (원자층 증착 방법을 이용한 폴리머 광도파로 제작)

  • Eun-Su Lee;Kwon-Wook Chun;Jinung Jin;Ye-Jun Jung;Min-Cheol Oh
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.4
    • /
    • pp.175-183
    • /
    • 2024
  • Research into optical signal processing using photonic integrated circuits (PICs) has been actively pursued in various fields, including optical communication, optical sensors, and quantum optics. Among the materials used in PIC fabrication, polymers have attracted significant interest due to their unique characteristics. To fabricate polymer-based PICs, establishing an accurate manufacturing process for the cross-sectional structure of an optical waveguide is crucial. For stable device performance and high yield in mass production, a process with high reproducibility and a wide tolerance for variation is necessary. This study proposes an efficient method for fabricating polymer optical-waveguide devices by introducing the atomic layer deposition (ALD) process. Compared to conventional photoresist or metal-film deposition methods, the ALD process enables more precise fabrication of the optical waveguide's core structure. Polyimide optical waveguides with a core size of 1.8 × 1.6 ㎛2 are fabricated using the ALD process, and their propagation losses are measured. Additionally, a multimode interference (MMI) optical-waveguide power-splitter device is fabricated and characterized. Throughout the fabrication, no cracking issues are observed in the etching-mask layer, the vertical profiles of the waveguide patterns are excellent, and the propagation loss is below 1.5 dB/cm. These results confirm that the ALD process is a suitable method for the mass production of high-quality polymer photonic devices.

An Experimental Study on Flocculation and Settling of Fine-grained Suspended Sediments (부유물질의 응접작용 및 침전특성에 관한 실험적 연구)

  • Chu, Yong-Shik;Park, Yong-Ahn;Lee, Hee-Jun;Park, Kwang-Soon;Kweon, Su-Jae
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.1
    • /
    • pp.40-49
    • /
    • 1999
  • A laboratory flume experiment, using turbulence-generating acryl tank and natural sediments, was conducted to investigate the effects of salinity, concentration of suspended sediment, turbulence and clay minerals on the flocculation and settling of fine-grained suspended sediments. While experiments were run, a sequence of water samples were taken near the bottom of the tank to analyze the variations of size distribution and relative contents of clay minerals. The results of the salinity experiment indicate that median settling velocity ($W_{50}$) increases linearly with salinity. Different settling processes of suspended sediments under variable concentrations appear to be predictable, depending upon the range of the suspension concentration. At concentrations less than 200 mg/l, $W_{50}$ is rarely varied with concentration probably because of the individual--grain settling mode. In the range of 200 to 13,000 mg/l show $W_{50}$ and concentration a good relationship following an empirical formula: $W_{50}=0.45C^{0.44}$. This relationship, however, no longer holds in concentrations exceeding 13,000 mg/l; instead, a more or less reverse one is shown. This result suggests an effect of hindered settling. The turbulence effect is somewhat different from that of concentration. Turbulence accelerates the flocculation and settling susepended sediments at low concentration (200 mg/l), whereas at high concentration turbulence breaks floes down and impedes the settling. Size distribution of suspended sediments sampled near the bottom of the tank tend to be more negatively skewed and leptokurtic in turbulent conditions compared to those in static conditions. The clay mineral analysis from the sequential water samples shows that over time the content of smectite decreases most rapidly with illite remaining concentrated in suspension. This means that smectite, among other clay minerals, plays the most effective role in the flocculation of fine-grained sediment in saline water.

  • PDF

Morphology, Mineralogy and Genetic Implication of Placer Gold from the Huongkhe Area, Vietnam (베트남 홍케 지역 사금의 산상과 생성연구)

  • Choi, Sang-Hoon;Choi, Seon-Gyu;Han, Jin-Kyun
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.235-246
    • /
    • 1996
  • Placer gold in collected heavy minerals from several localities in Huongkhe area, is consistently very finegrained (${\leq}100$ to $400{\mu}m$). The size and size distribution show somewhat differences at Dongdo and Hoahai : at Dongdo, predominant relatively larger and wide distribution; at Hoahai, characteristic relatively finer and narrow distribution range. The morphology of gold grains is divided into the four groups assumed by the dimension ratio : spherical, subprismoidal, prismoidal, and irregular. The gold grains at Dongdo show wide morphological distribution, whereas, at Hoahai, spherical form is predominant (${\approx}75%$). Three main types of gold are classified based on their chemical composition and mode of occurrence: type I (electrum; fineness=568~931), type II (amalgam; fineness=671~927), and type III (native gold; fineness=923~999). Type I gold contains, relatively high and variable silver contents (${\approx}11$ to 58 atomic % Ag), and has been classified into two subtypes based on their silver contents (type IA, ${\approx}11{\sim}39$ atomic % Ag; type IB, ${\approx}40{\sim}58$ atomic % Ag). However, type I gold would have been generally original compositions of electrum which originated at the provenance deposits. Mercury reacts with gold and silver to form amalgam (type II gold) which has variable Hg contents (1.2~30.5 atomic % Hg). The mercury contents in gold grains at Hoahai (10.9~30.5 atomic % Hg) are higher than those at Dongdo (5.8~21.1 atomic % Hg). The gold grains from the area generally exhibit a high-purity gold (type III) rim. The individual rims on the various grains range from <1 to $80{\mu}m$ in thickness and have silver contents of <10 atomic percent Ag, even though the core compositions range from ${\approx}11$ to 58 atomic percent Ag. The rim of gold most likely is responsible for the commonly cited cases of gold from placer deposits assaying at higher values of fineness than the gold in the corresponding source lode. The gold-rich rim in the Huongkhe area apparently forms by a combination of self-electrorefining and preferential dissolution of silver under oxidizing nature during the weathering and transport process. All data of gold grains in the Huongkhe area suggest that the transport distances and/or time of placer gold at Hoahai are generally farther than those at Dongdo. The mercurian gold bearing provenance deposits at Dongdo and Hoahai would be suggest nearest epithermal gold-silver vein-type.

  • PDF

Effect of adaptive movement on durability and working time of twisted file (Adaptive movement가 twisted file의 내구성과 작업 시간에 미치는 영향)

  • Lee, Sang-Ho;Park, So-Ra;Cho, Kyung-Mo;Park, Se-Hee;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.20-26
    • /
    • 2019
  • Purpose: Recently TF-adaptive movement is developed in order to increase the durability of TF files. The purpose of this study was to assess the effects of adaptive movement on durability and performance of twisted files. Materials and Methods: Resin blocks simulating artificial J-shape canals were used for this study. In TFC group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under continuous rotation 500 rpm/4.0 Ncm. In TFA group, TF-adaptive ML-1 (25/.08 size) files were used to prepare the canals under adaptive movement. After preparing each artificial canal, TF files were observed under dental microscope for assessing existence of unwinding, distortion, and fracture. If unwinding of flute was observed, the number of artificial canals until unwinding of flute occurs was recorded. Required time until instruments reach working length and distance of unwinded portion of files from D0 were measured. All test results were conducted by Mann-Whitney U test at a 0.05 level of significance. Results: No Ni-Ti instrument's separation was observed. Number of resin blocks until file unwinding happens and working time was significantly high in TFA group compared to TF group. Distance of distortion from D0 didn't show significant difference between TFA, TF groups. Conclusion: The number of resin blocks prepared until unwinding happens and working time were significantly high in TFA group. The location of unwinding showed no significant difference between 2 groups. Adaptive movement increased the number of canals prepared until unwinding occurs and working time of twisted files.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Role of Postoperative Conventional Radiation Therapy in the Management of Supratentorial Malignant Glioma - with respect to survival outcome and prognostic factors - (천막상부 악성 신경교종에서 수술 후 방사선 치료의 역할 - 생존율과 예후인자 분석 -)

  • Nam Taek Keun;Chung Woong Ki;Ahn Sung Ja;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.389-398
    • /
    • 1998
  • Purpose : To evaluate the role of conventional postoperative adjuvant radiotherapy in the management of supratentorial malignant glioma and to determine favorable prognostic factors affecting survival. Materials and Methods : From Sep. 1985 to Mar. 1997, the number of eligible patients who received postoperative radiotherapy completely was 69. They ranged in age from 7 to 66 years (median, 47). Forty-two (61$\%$) patients were glioblastoma multiforme and the other 27 (39$\%$) were anaplastic astrocytoma. Twenty patients (29$\%$) had Karnofsky score equal or more than 80 preoperatively. Forty-three patients (62$\%$) had symptom duration equal or less than 3 months. Twenty-four patients (35$\%$) had gross total resection and forty patients(58$\%$) had partial resection, the remaining five patients (7$\%$) had biopsy only. Radiotherapy dose ranged from 50.4 Gy to 61.2 Gy (median, 55.8; mode, 59.4) with fraction size of 1 8 Gy-2.0 Gy for 33-83 days(median, 48) except three patients delivered 33, 36, 39 Gr, respectively with fraction size of 3.0 Gy due to poor postoperative performance status. Follow-up rate was 93$\%$ and median follow-up period was 14 months. Results : Overall survival rate at 2 and 3 years and median survival were 38$\%$, 20$\%$, and 16 months for entire patients; 67$\%$, 44$\%$, and 34 months for anaplastic astrocytoma; 18$\%$, 4$\%$, and 14 months for glioblastoma multiforme, respectively (p=0.0001). According to the extent of surgery, 3-year overall survival for gross total resection, partial resection, and biopsy only was 38$\%$, 11$\%$, and 0$\%$, respectively (p=0.02) The 3-year overall survival rates for patients age 40>, 40-59, and 60< were 52$\%$, 8$\%$, and 0$\%$, respectively (p=0.0007). For the variate of performance score 80< vs 80>, the 3-year survival rates were 53$\%$ and 9$\%$, respectively (p=0.008). On multivariate analysis including covariates of three surgical and age subgroups as above, pathology, extent of surgery and age were significant prognostic factors affecting overall survival. On another multivariate analysis with covariates of two surgical (total resection vs others) and two a9e (50> vs 50<) subgroups, then, pathology, extent of surgery and performance status were significant factors instead of age and 3-year cumulative survival rate for the five patients with these three favorable factors was 100$\%$ without serious sequela. Conclusion : We confirmed the role of postoperative conventional radiotherapy in the management of supratentorial malignant glioma by improving survival as compared with historical data of surgery only. Patients with anaplastic astrocytoma, good performance score, gross total resection and/or young age survived longest. Maximum surgical resection with acceptable preservation of neurologic function should be attempted in glioblastoma patients, especially in younger patients. But the survival of most globlastoma patients without favorable factors is still poor, so other active adjuvant treatment modalities should be tried or added rather than conventional radiation treatment alone in this subgroup.

  • PDF

Distribution and Pollution Assessment of Trace Metals in the Surface Sediments around Farming Area of Jinhae Bay (진해만 양식어장 주변 표층 퇴적물 중 미량금속의 분포 특성 및 오염 평가)

  • Choi, Tae-Jun;Kwon, Jung-No;Lee, Garam;Hwang, Hyunjin;Kim, Youngsug;Lim, Jae-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.4
    • /
    • pp.347-360
    • /
    • 2015
  • Trace metals(As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Pb and Zn) concentrations in surface sediments of Jinhae bay in August of 2013 were measured to investigate the characteristics of trace metals distribution and to evaluate the metal pollution. Assessment for metal pollution was carried out using the sediment quality guidelines(SQGs) such as threshold effects level(TEL) and probable effects level(PEL) proposed by the ministry of onceans and fisheries(MOF) in Korea and geochemical assessment techniques(enrichment factor(EF) and geoaccumulation index ($I_{geo}$)). The mean concentration of trace metals in the sediments are as follows: 11.1 mg/kg for As, 0.52 mg/kg for Cd, 14.1 mg/kg for Co, 69.8 mg/kg for Cr, 57.2 mg/kg for Cu, 3.7 % for Fe, 0.064 mg/kg for Hg, 600 mg/kg for Mn, 40.1 mg/kg for Pb, 167.2 mg/kg for Zn. The spatial distributions of As, Co, Cr and Fe were not distinguished clearly in whole area. However, Cd, Hg, Pb and Zn were high in northern area of bay, and Cu and Mn were high in southeastern and eastern area of bay, respectively. The distribution pattern of trace metals, correlation matrix and R-mode factor analyses results revealed that the distribution of trace metals were mainly effected by the sediment grain size(Co, Cr and Fe), redox condition of sediments(Mn) and anthropogenic factors(As, Cd, Cu, Hg, Pb and Zn). Comparing the concentrations of several trace metals(As, Cd, Cr, Hg and Pb) with SQGs from Korea(TEL and PEL), the concentrations of Hg, Cd and Pb in sediment of northern area of bay were higher than TEL. EF and $I_{geo}$ values of As, Cd, Cu, Hg, Mn, Pb and Zn showed that these metals in sediments are enriched by anthropogenic activities in some areas, and pollution status for Cd, Hg and Pb in northern area and Cu in southeastern area of bay were concerned about current level, although those for As, Mn and Zn were not.

Transarterial embolization of renal artery in dogs with experimental hydronephrosis (개의 실험적 수신증에 실시한 신동맥 색전술)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.437-445
    • /
    • 2001
  • This study was performed to validate the procedure of transarterial embolization of the renal artery (TAE-RA) using iohexol-ethanol solution in dogs with unilateral experimental hydronephrosis and to evaluate the embolized kidney using B-mode ultrasonography and selective angiography. Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. Ultrasonographic findings revealed that size of the kidney was significantly increased at 9 days and 17 days and the length of renal cortex was significantly decreased at 17 days after ligation of the unilateral ureter and it was in accordance with dilation of ipsilateral renal pelvis. No significant change of BUN, creatinine, ALT, calcium, and phosphorus was found immediately after unilateral experimental hydronephrosis. Therefore, it was concluded that unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$, body temperature, pulse, and respiratory rate were within normal ranges during procedures. Iohexol-ethanol solution was used as embolic material. Average ethanol dose for renal artery embolization was $1.94{\pm}1.24ml/kg$. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. Revascularization of renal artery was not found in angiography in dogs treated by TAE-RA at immediately after TAE-RA and 14 days after TAE-RA. Ultrasonographically, the mean longitudinal length of the embolized kidney decreased significantly at 2 and 3 months after TAE-RA compared to that of contralateral normal kidney. In summary, marked shrinkage of the embolized kidney was observed in dogs with unilateral experimental hydronephrosis treated by TAE-RA with iohexol-ethanol and no adverse effects were observed throughout the observation period. It is concluded that TAE-RA with iohexol-ethanol solution is a viable alternative to nephrectomy in dogs with unilateral hydronephrosis.

  • PDF

A Study on Significance Testing of Driver's Visual Behavior due to the VMS Message Display Forms on the Road (도로상 VMS 표출방식별 운전자 유의성 검증에 관한 연구)

  • Kum, Ki-Jung;Son, Young-Tae;Bae, Deok-Mo;Son, Seung-Neo
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.151-162
    • /
    • 2005
  • Variable Message Sign (VMS), which provides drivers with direct information about state of traffic congestion and for prevent an accident, is the most effective method among the methods of providing information in Advanced Transportation Management System. Currently establishment and the VMS which is operated foundation lets in Guidelines on the use of Variable message sign (a book of the VMS) of 1999 November the Ministry Construction & Transportation, these contents mean main viewpoint on physical part such as message special quality variable (font, character size and line space, word interval) and position mainly among standard about establishment in general. But, it is true that using without effect verification on the character of VMS display and that using mode of stationary-centered. In this paper, it executed significance test to effort verification on the character of VMS display for more practical and effective information transmission based on the driver viewpoint For the researches; develop 3D-Simulation, select characteristics of driver's visual cognition behavior (the conspicuity, the legibility and the comprehensibility), evaluation each issue (day or night, 80km/h or 100km/h). Especially, that used the Eye Marker Recorder to measure of reading-time (legibility) thus, confirmed objectivity and reduce an observational error. The results showed that the conspicuity is Flashing> Stationary>Scroll. The legibility is not deference that Flashing between stationary form. Also the comprehensibility result showed that Flashing> Stationary>Stroll form.

  • PDF