• Title/Summary/Keyword: Mode Pair

Search Result 171, Processing Time 0.023 seconds

Development of Stereocopic-PIV and its Application to the Measurement of the Near Wake of a Circular Cylinder (Stereocopic-PIV 개발과 원주근접 후류 계측)

  • Doh, D.H.;Kim, D.H.;Cho, G.R.;Lee, W.J.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.555-559
    • /
    • 2001
  • A new stereoscopic PIV is developed using two CCD cameras, stereoscopic photogrammetry, and a 3D-PTV principle. The wake of a circular cylinder is measured by the developed stereoscopic PIV technique. The B mode vortical structure of the wake over the Reynolds number 300 is clearly seen by the developed technique. The arrangement of the two cameras is based on angular position. The calibration of cameras and the pair-matching of the three-dimensional velocity vectors are based on 3D-PTV technique.

  • PDF

Mass Spectrometric Analysis for Discrimination of Diastereoisomers

  • Manshoor, Nurhuda;Weber, Jean-Fré
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.99-104
    • /
    • 2015
  • A liquid chromatography mass spectrometry (LC-MS) system was used to identify and distinguish oligostilbene diastereoisomers. A polyphenolic extract from Neobalanocarpus heimii known to be rich in oligostilbenes of various degrees of condensation was used as test material. Fourteen oligostilbenes were isolated from this extract on a fully automated semi-preparative HPLC system. Out of these, two pairs of dimers, one pair of trimers, two pairs of tetramers and a group of four tetramers with similar skeleton were identified as diastereoisomers. Their structures and configurations were established by spectroscopic methods. All isolated compounds were subjected to an LC-MS/MS to study their fragmentation patterns. The experiments were performed on a liquid chromatography-mass spectrometry (LC-MS) with electrospray-ionization (ESI) interface in positive mode. MS/MS spectra of each pure compound were recorded by direct infusion in identical conditions and their product ion spectra were analysed. Some subtle yet significant differences were observed between the spectra of oligostilbenes from the various diastereoisomeric series.

Studies on the Mechanism of Resistance to and Mode of Action of Viomycin in Mycobacterium smegmatis (Mycobacterium smegmatis를 이용한 Viomycin의 내성 및 작용 기전에 관한 연구)

  • 최응칠
    • YAKHAK HOEJI
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 1980
  • Viomycin inhibited polypeptide biosynthesis, initiation complex formation and translocation of peptidyl-tRNA on ribosomes derived from a sensitive strain of Mycobacterium smegmatis (R-15), but not significantly on ribosomes from viomycin-resistant mutants(R-31 and R-43). The inhibition of translocation was stronger than that of initiation complex formation in the sensitive strain. The binding of [$^{14}C$] tuberactinomycin O, a viomycin analog, to ribosomal particles was studied by Millipore filter method. The sensitive ribosome exhibited higher affinity for the antibiotic than the resistant ribosomes. The resistance was localized on the large ribosomal subunit in a mutant(R-31), and on the small subunit in another mutant(R-43). The binding of the drug to the sensitive ribosomal subunit was markedly reduced by combination with the resistant pair subunit, and the entire ribosome became resistant to the antibiotic.

  • PDF

Development of a Simulator for the biped-walking robot using the open inventor (Open Inventor를 이용한 이족보행로봇의 시뮬레이터의 개발)

  • 최형식;김영식;전대원;우정재;김명훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.296-299
    • /
    • 2001
  • We developed a motion capture system to get angle data of human joints in the walking mode. The motion capture system is a pair of leg-shape device, which is composed of three links with ankle, knee and pelvis joints. The sensors for measurement of the joint angle are potentiometers. We used an A/D converter to get digital data from joint angles, and which are used to simulate and coordinate the biped-walking robot developed in our laboratory. To simulate and analyze walking motion, animation based on three-dimension motion is performed using the open inventor software.

  • PDF

Walking motion capture system for the biped-walking robot (이족 보행로봇의 걸음새구현을 위한 모셔냅쳐 시스템)

  • 최형식;김영식;전대원;김명훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.114-117
    • /
    • 2000
  • We developed a motion capture system to get angle data of human joints in walking mode. The data are used to coordinate the biped-walking robot developed in our laboratory. A pair of motion capture system is composed of three links with the ankle, knee, and pelvis joints. The system has six axes attached with potentiometers. We used an A/D converter was used to get digital data from joint angles. We filterd the data using the Butterworth 4th order digital filter, and simulated walking motion based on the data using the Matlab.

  • PDF

Optimization of Data Acquisition System with Parallel Collection for PET

  • Yoshida, Eiji;Shimizu, Keiji;Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.311-313
    • /
    • 2002
  • We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this scanner, a maximum data transfer rate of coincidence pair's event information is 10 Mcps and one event is a 64-bit data format. This maximum data transfer rate corresponds by 10 times a conventional PET scanner. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Data transfer rate is improved by optimizing parameters of a message size, and so on.

  • PDF

Compact and versatile range-finding speedometer with wide dynamic range

  • Shinohara, Shigenobu;Pan, Derong;Kosaka, Nozomu;Ikeda, Hiroaki;Yoshida, Hirofumi;Sumi, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.158-161
    • /
    • 1995
  • A new laser diode range-finding speedometer is proposed, which is modulated by a pair of positive and negative triangular pulse current superimposed on a dc current. Since a target velocity is directly obtained form a pure Doppler beat frequency measured during the non-modulation period, the new sensor is free from the difficulties due to the critical velocity encountered in the previous sensor. Furthermore, the different amplitude of the two triangular pluses are so adjusted that the measurable range using only one laser head is greatly expanded to 10cm through 150cm, which is about two times that of the previous sensor. The measurement accuracy for velocity of .+-.6mm/s through .+-.20mm/s and for range is about 1%, and 2%, respectively. Because the new sensor can be operated automatically using a microcomputer, it will be useful for application of a 3-D range image measurement of a slowly moving object.

  • PDF

Transcoding Algorithm for SMV and G.723.1 Vocoders via Direct Parameter Transformation (SMV와 G.723.1 음성부호화기를 위한 파라미터 직접 변환 방식의 상호부호화 알고리듬)

  • 서성호;장달원;이선일;유창동
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2228-2231
    • /
    • 2003
  • In this paper, a transcoding algorithm for the Selectable Mode Vocoder (SMV) and the G.723.1 speech coder via direct parameter transformation is proposed. In contrast to the conventional tandem transcoding algorithm, the proposed algorithm converts the parameters of one coder to the Other Without going through the decoding md encoding process. The proposed algorithm is composed of four parts: the parameter decoding, line spectral pair (LSP) conversion, pitch period conversion, excitation conversion and rate selection. The evaluation results show that the proposed algorithm achieves equivalent speech quality to that of tandem transcoding with reduced computational complexity and delay.

  • PDF

Image storage & display using transparent 7/65/35 PLZT ceramics (투명 7/65/35 PLZT 세라믹을 이용한 Image Storage & Display에 관한 연구)

  • Lee, Kae-Myeng;Yoo, Ju-Hyun;Wee, Kyu-Jin;Jeong, Ik-Che;Park, Chang-Yup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.13-16
    • /
    • 1988
  • In this paper, image storage and display of scattering mode using 7/65/35 PLZT ceramics was studied. Scattering in a ferroelectric poly-crystal depends on its grain size and domain orientations. 7/65/35 PLZT ceramics is ferroelectric and transparent. Image can be stored in the ceramic substrate by poling it selectively through a pair of electrodes with the pattern or a set of a photoconductivity film and two transparent electrodes.

  • PDF

Analysis of KOMPSAT-5 Orbit for Radargrammetry at Different Latitudes (Radargrammetry 적용을 위한 위도에 따른 KOMPSAT-5 궤도 분석)

  • Jang, So-Young;Lee, Hoon-Yol
    • Proceedings of the KSRS Conference
    • /
    • 2008.03a
    • /
    • pp.63-66
    • /
    • 2008
  • 2010년 5월에 발사 예정인 KOMPSAT-5(KOrea Multi-Purpose SATellite-5)는 KOMPSAT-1, 2호에 탑재된 광학센서와는 달리 기상상태와 태양고도에 제약을 받지 않고 자료 획득이 가능한 SAR 시스템이 탑재된다. 본 연구에서는 KOMPSAT-5의 SAR 시스템으로부터 radargrammetry 기법을 적용하기 위해 위성의 궤도와 영상 모드를 분석하였다. Radargrammetry 적용을 위한 SAR 영상 pair의 parallax의 height sensitivity를 이론상으로 계산하였다. 그리고 STK 소프트웨어를 사용하여 대전과 남극 세종기지에서의 최적 조건을 각각 예시하였다. 입사각이 20$^{\cric}$-45$^{\cric}$가 되는 nominal mode의 descending pass만을 사용하여 height sensitivity가 0.5-0.75 사이의 영상 조합을 찾았다. 그 결과 Pass Number 쌍으로서, 대전은 5-4, 7-5, 8-5의 영상 조합을 하였을 때 radargrammetry 적용이 용이하고, 남극 세종기지는 8-6, 9-7, 10-7, 11-8, 12-8, 13-9, 14-9, 15-9, 15-10, 15-11의 영상 조합을 하였을 때 radargrammetry 적용이 가능한 것으로 예측되었다.

  • PDF