• Title/Summary/Keyword: Mode Mixing

Search Result 152, Processing Time 0.023 seconds

Design of Polarization-Insensitive Directional Couplers and Multimode Interference Couplers Integrated with Bragg Grating Waveguide (Bragg 격자구조가 집적된 편광 무의존성 방향성 결합기와 다중모드 간섭 결합기의 설계)

  • Ho, Kwang-Chun
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.295-302
    • /
    • 2007
  • This paper presents a rigorous comparison of the design characteristics of polarization-insensitive directional coupler (DC) and multimode interference (MMI) coupler based on rib type waveguides, by using longitudinal modal transmission-line theory (L-MTLT). It shows that the multimode mixing and interference property of MMI can be structurally designed through the continuous evolution of the two-mode coupling property of DC. It also compares and analyzes the coupling efficiency along with the coupling length and the wavelength between polarization-insensitive DC and MMI. From the design properties obtained, it demonstrates for the first time the integration of polarization-insensitive DC or MMI with a Bragg grating and evaluates precisely the filtering characteristics. The numerical results reveal that the DC, as long as it is designed to have the same coupling length for TE and TM modes, has better performance than the MMI in polarization-insensitive filtering behaviour. However, it shows that the MMI with much less coupling length than DC is preferred in the miniaturization of integrated devices.

Effect of Injector Design on Combustion Characteristics of Full-scale Gas Generators (분사기 설계에 따른 실물형 가스발생기 연소특성 비교)

  • Ahn, Kyu-Bok;Seo, Seong-Hyeon;Lee, Kwang-Jin;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.309-315
    • /
    • 2006
  • Effects of injector or design on combustion characteristics of full-scale gas generators were studied. Three full-scale gas generators, which have same total mass flow rate but mass flow rate per injector is different depending on their designs, were manufactured. Thirteen, nineteen and thirty seven injectors, which have internal-mixing and double-swirl characteristics, are distributed in injector heads, respectively. The results showed that special pressure fluctuations in the gas generators with 13 and 19 injectors didn't appear around longitudinal resonant frequency, but small longitudinal-mode instability appeared in the gas generator with 37 injectors. As the number of injectors installed in injector heads increased, temperature distribution in combustion chambers showed small deviations, but the damage of LOx posts increased.

  • PDF

Optimization of Environmental Parameters for Extracellular Chitinase Production by Trichoderma harzianum SJG-99721 in Bioreactor (Trichoderma harzianum SJG-99721의 체외 분비 chitinase 생산에 미치는 생물 반응기에서의 반응 최적화 연구)

  • 이호용
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.1
    • /
    • pp.167-170
    • /
    • 2004
  • A self-directing optimization procedure was applied to determine the best environmental factors in operating the bioreactor. The self-directing optimization process was employed to determine the best conditional combination of multi parameters, pH, temperature, aeration rate and mixing rate toy maximal production of chitinase by Trichoderma harzianum SJG-99721 in batch mode fermentation. Among these factors, the parameters of pH and aeration rate were found to be particularly important on mycellial growth and chitinase activity. pH 4.89, an aeration rate of 3.22 ι per minute and an agitation rate of 225 rpm was found to be the best combination. By the optimization, chitinase activity was dramatically increased from an initial value of 4.221 U under basic conditions to n final value of 16.825 U.

Utilization of Mineral Oxides to Attenuate Mn-EDTA and Fluoride (산화광물을 이용한 수중의 망간-EDTA, 불소 제거)

  • 현재혁;남인영
    • Journal of Korea Soil Environment Society
    • /
    • v.1 no.2
    • /
    • pp.51-60
    • /
    • 1996
  • Removal of Mn-EDTA complex and fluoride by use of hematite and ferrite, which are the by-product to be disposed of as industrial wastes, was investigated. For the comparison of removal rate, Na-bentonite known as excellent absorbent of inorganic contaminants was included in the experiments. As the results of batch mode experiments, for manganese, ferrite-A revealed 48∼65% of removal capacity, ferrite-B 46∼57%, hematite 17∼26%, while Na-bentonite showed 10∼23% of removal, depending on the initial concentration. Meanwhile, in case of fluoride : hematite revealed 53 ∼63% of removal : ferrite-A 54∼63 %, while ferrite-B did 20∼38 %. From the results, it can be postulated that the capacity of hematite and ferrite to attenuate inorganic pollutants, especially when they form complex ions, is superior to that of Na-bentonite. Consequently, the mixing of such oxide minerals with Na-bentonite will reinforce the function of Na-bentonite, especially in the undergroud liner aspect.

  • PDF

Application of CE-QUAL-W2 [v3.2] to Andong Reservoir: Part I: Simulations of Hydro-thermal Dynamics, Dissolved Oxygen and Density Current

  • Bhattarai, Prasid Ram;Kim, Yoon-Hee;Heo, Woo-Myoung
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.247-263
    • /
    • 2008
  • A two-dimensional (2D) reservoir hydrodynamics and water quality model, CE-QUAL-W2, is employed to simulate the hydrothermal behavior and density current regime in Andong Reservoir. Observed data used for model forcing and calibration includes: surface water level, water temperature, dissolved oxygen and suspended solids concentration. The model was calibrated to the year of 2003 and verified with continuous run from 2000 till 2004. Without major adjustments, the model accurately simulated surface water levels including the events of large storm. Deep-water reservoirs, like Andong Reservoir, located in the Asian Monsoon region begin to stratify in summer and overturn in fall. This mixing pattern as well as the descending thermocline, onset and duration of stratification and timing of turnover phenomenon were well reproduced by the Andong Model. The temperature field and distinct thermocline are simulated to within $2^{\circ}C$ of observed data. The model performed well in simulating not only the dissolved oxygen profiles but also the metalimnetic dissolved minima phenomenon, a common1y occurring phenomenon in deep reservoirs of temperate regions. The Root Mean Square Error (RMSE) values of model calibration for surface water elevation, temperature and dissolved oxygen were 0.0095 m, $1.82^{\circ}C$, and $1.13\;mg\;L^{-1}$, respectively. The turbid storm runoff, during the summer monsoon, formed an intermediate layer of about 15 m thickness, moved along the metalimnion until being finally discharged from the dam. This mode of transport of density current, a common characteristic of various other large reservoirs in the Asian summer monsoon region, was well tracked by the model.

Formation of SiC Particle Reinforced Al Metal Matrix Composites by Spray Forming Process(I. Microstructure) (분사성형법에 의한 SiC입자강화 알루미늄 복합재료의 제조 I. 미세조직에 대한 고찰)

  • Park, Jong-Sung;Kim, Myung-Ho;Bae, Cha-Hurn
    • Journal of Korea Foundry Society
    • /
    • v.13 no.4
    • /
    • pp.369-381
    • /
    • 1993
  • Aluminum alloy(AC8A) matrix composites reinforced with SiC particles(10% in vol.) were fabricated by Centrifugal Spray Deposition(CSD) process. The microstructures were investigated in order to evaluate both the mixing mode between aluminum matrix and SiC particles, and the effect of SiC particles on the cooling behaviours of droplets during flight and preforms deposited. A non-continuum mathematical calculation was performed to explain and to quantify the evolution of microstructures in the droplets and preforms deposited. Conclusions obtained are as follows; 1. The powders produced by CSD process showed, in general, ligament type, and more than 60% of the powders produced were about 300 to 850 um in size. 2. AC8A droplets solidified during flight showed fine dendritic structure, but AC8A droplets mixed with SiC particles showed fine equiaxed grain structure, and eutectic silicon were formed to crystallize granularly between fine aluminum grains. 3. SiC particles seem to act as a nucleation sites for pro-eutectic silicon during solidification of AC8A alloy. 4. The microstructure of composite powders formed by CSD process showed particle embedded type, and resulted in dispersed type microstructure in preforms deposited. 5. The pro-eutectic silicon crystallized granularly between fine aluminum grains seem to prohibit grains from growth during spray deposition process. 6. The interfacial reactions between aluminum matrix and SiC particles were not observed from the deposit performs and the solidified droplets. 7. The continuum model seem to be useful in connecting the processing parameters with the resultant microstructures. From these results, it was concluded that the fabrication of aluminum matrix composites reinforced homogeneously with SiC particles was possible.

  • PDF

Improved Harmonic-CELP Speech Coder with Dual Bit-Rates(2.4/4.0 kbps) (이중 전송률(2.4/4.0 kbps)을 갖는 개선된 하모닉-CELP 음성부호화기)

  • 김경민;윤성완;최용수;박영철;윤대희;강태익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.3C
    • /
    • pp.239-247
    • /
    • 2003
  • This paper presents a dual-rate (2.4/4.0 kbps) Improved Harmonic-CELP(IHC) speech coder based on the EHC(Efficient Harmonic-CELP) which was presented by the authors. The proposed IHC employs the harmonic coding for voiced and the CELP for unvoiced segments. In the IHC, an initial voiced/unvoiced estimate is obtained by the pitch gain and energy. Then, the final V/UV mode is decided by using the frame energy contour. A new harmonic estimation combining peak picking and delta adjustment provides a more reliable harmonic estimation than that in the EHC. In addition, a noise mixing scheme in conjunction with an improved band voicing measurement provides the naturalness of the synthesized speech. To demonstrate the performance of the proposed IHC coder, the coder has been implemented and compared with the 2.0/4.0 kbps HVXC(Harmonic excitation Vector Coding) standardized by MPEG-4. Results of subjective evaluation showed that the proposed IHC coder and produce better speech quality than the HVXC, with only 40% complexity of the HVXC.

Reflection on Kinetic Models to the Chlorine Disinfection for Drinking Water Production

  • Lee, Yoon-Jin;Nam, Sang-ho
    • Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.119-124
    • /
    • 2002
  • Experiments for the characterization of inactivation were performed in a series of batch processes with the total coliform used as a general indicator organism based on the chlorine residuals as a disinfectant. The water samples were taken from the outlet of a settling basin in a conventional surface water treat- ment system that is provided with the raw water drawn from the mid-stream of the Han River, The inactivation of total coliform was experimentally analysed for the dose of disinfectants contact time, filtration and mixing intensity. The curves obtained from a series of batch processes were shaped with a general tailing-off and biphasic mode of inactivation, i.e. a sharp loss of bacterial viability within 15 min followed by an extended phase. In order to observe the effect of carry-over suspended solids on chlorine consumption and disinfection efficiency, the water samples were filtered, prior to inoculation with coliforms, with membranes of both 2.5$\mu$m and 11.0 $\mu$m pore size, and with a sand tilter of 1.0 mm in effective size and of 1.4 in uniformity coefficient. As far as the disinfection efficiency is concerned, there were no significant differences. The parameters estimated by the models of Chick-Wat-son, Hom and Selleck from our experimental data obtained within 120 min are: log(N/N$\_$0/)=-0.16CT with n=1, leg(N/N$\_$0/)=-0.71C$\^$0.87/ with n 1 for the Chick-Watson model, log (N/N$\_$0/)=-1.87C$\^$0.47/ T$\^$0.36/ for the Hom model, log (MHo)=-2.13log (1+CT/0.11) for the Selleck model. It is notable that among the models reviewed with regard to the experimental data obtained, the Selleck model appeared to most closely resemble the total coliform survival curve.

Vortex pairing in an axisymmetric jet using fundamental and subharmonic forcing (기본교란 및 분수조화교란을 이용한 원형제트에서의 보텍스병합)

  • Jo, Seong-Gwon;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1350-1362
    • /
    • 1997
  • An experimental study has been performed on vortex pairing under fundamental and subharmonic forcing with controlled initial phase differences through hot-wire measurements and a multi-smoke wire flow visualization. For the range of St$_{D}$ < 0.6, vortex pairing was controlled by means of fundamental and subharmonic forcing with varying initial phase differences. Much larger mixing rate was achieved by two-frequency forcing with a proper phase difference than one frequency forcing. As St$_{D}$ decreased, vortex pairing was limited to a narrow region of the initial phase difference between two disturbances and higher amplitudes of the fundamental and its subharmonic at the nozzle exit were required for more stable pairing. As the amplitude of the subharmonic at the nozzle exit increased for fixed St$_{D}$ and fundamental amplitude, the distribution of the subharmonic mode against the variation of the initial phase difference changed from a sine function form into a cusp-like form. Thus, vortex pairing can be controlled more precisely for the former case. For St$_{D}$ > 0.6, non-pairing advection of vortices due to the improper phase difference was sometimes observed in several fundamental forcing amplitudes when only the fundamental was applied. However, when its subharmonic was added, vortex pairing readily occurred. As the initial amplitude of this subharmonic increased, the position of vortex pairing moved upstream. This was thought to be due to the fact that the variation of the initial phase difference between the fundamental and its subharmonic has less effects on vortex pairing in the region of fundamental-only vortex pairing.pairing.

Experimental study on the damping estimation of the 5$\times$5 rod bundle (5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF