• Title/Summary/Keyword: Modbus Network

Search Result 15, Processing Time 0.024 seconds

Development of User Protocol Converter about Modbus and NMEA0183 (Modbus와 NMEA0183에 대한 사용자 프로토콜 컨버터 개발)

  • Eum, Sang-hee;Hong, Sung-ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2584-2589
    • /
    • 2015
  • In this paper, we want to able to reduce the time effectively about the analysis of protocol and development of protocol converter in industrial network. For this purpose, we developed the user protocol converter that can be to analysing the communication protocol in the industrial network. and also that is able to converting to user protocol and transmitting to another network. The developed user protocol converter was consist of S/W and H/W, and is supporting the Modbus, the NMEA0183 and the ethernet. The hardware main processor was used the AVR128, and placed the serial communication part and the ethernet part in converter board. The experiment results, we acquired very high transmission rate and conversion rate.

Design and Implementation of Distributed Control System based on Dual Field-bus for Ship Engine (이원화된 필드버스 기반의 선박 엔진용 분산 제어 시스템의 설계 및 구현)

  • Lee, Jae-Hyung;Kim, Dong-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.1-9
    • /
    • 2012
  • In this paper, we design and implement a DCS (Distributed Control System) based on dual field-bus for ship engine. For monitoring and controlling the condition of the ship engine, an implemented DCS is consisted of two-tier communication structure by using CAN (Controller Area Network) and MODBUS protocols. The first-tier is consisted of CAN protocol for sharing the condition of the ship engine by each implemented monitoring system. By using MODBUS protocol, the second-tier is used for communicating the monitoring data from an implemented DCS to AMS(Alarm Monitoring System). We verified and tested our scheme and implemented DCS by KR (Korea Register) technical rules through experimental tests.

Performance Analysis and Improvement of RS485 Based Low Speed and Multi-Node CSMA/CD for Control Network System (RS485 기반 다수 노드 제어용 저속통신망에서의 CSMA/CD 기법 적용 및 성능 개선 방안)

  • Kim, Min Ki;Choi, Yong Wo;Park, Dong Chan;Kim, Suk Chan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.27-35
    • /
    • 2015
  • In this paper, we suggested a RS485 based CSMA/CD protocol that is available in low speed multi-node networks such as industry control communication network and home network etc. The suggested protocol was compared to widely used Master-Slave protocol, Modbus. We modeled realistic control network and showed that the average delay and throughput performance were significantly improved in the different transmission rates.

PLC and Arduino Interaction Based on Modbus Protocol

  • Jeong, Yunju;Ansari, Md Israfil;Shin, WooHyeon;Kang, Bonggu;Lim, JinSeop;Moon, HyeonSik;Shim, Jaechang
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.3
    • /
    • pp.511-519
    • /
    • 2017
  • This Paper introduces the design and communication method between PLC (Programmable Logic Controller) and Arduino based on MODBUS Protocol. MODBUS connection can be established in a new or existing system very easily, therefore we used this protocol in our proposed system. In the field of automatic devices, multi-function serial port such as RS232, RS422, RS485, and so on creates a great convenience to the developer. This proposed system used RS485 as a key mediator for data exchanging on a connected network. We also believe that it will reduce the development cost in various automated industry because this system can be reused or can be implemented any such PLC installed machines. RS485 is used as a communication interface between PLC (as a slave) and Arduino (as a master), through which a reliable network is created for safe and fast communication. Furthermore, RS485 allows multiple devices(up to 32) to communicate at half duplex on a single pair of wires and provides a long connectivity area (up to 1200 meters) as compare to other device, which makes it a user-friendly for various devices in the automated industry. Moreover, Arduino can play as a mediator by connecting third party device and setup a communication network with PLC.

Development of DSP-based Modbus Communication Scheme and Control Module for Controlling Actuators in Industrial Equipment (산업용 장비에서의 액추에이터를 제어 하기 위한 DSP에서의 Modbus통신 구현과 제어 모듈 개발)

  • Kim, Won-Jun;Gwak, Dong-Gi;Kim, Dong Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1109-1117
    • /
    • 2017
  • In this work, a new control module and communication system associated with DSP are proposed to overcome the limitations of the contemporary prevailing PLC-based industrial equipment controller, and the performance of the proposed system was experimentally verified. In the light of this issue, a communication conversion scheme from RS-485 to Modbus, the dominant communication protocol used by PLC, was developed and shown to yield enhanced compatibility between devices. The proposed system allows for ~50% cost reduction as well as downsizing of the industrial controllers. Furthermore, the design includes 24 V general digital I/O pins, which facilitate partial expansion of inputs and outputs. With Modbus communication implemented in DSP with the RS-485 interface, multi-to-multi communication may also be achieved.

Development of Integrated Water Operation System through Engineering Standardization (표준화를 통한 통합형 수(水)운영시스템의 개발)

  • Han, Geung-Jeon;Kim, Jin-Mun;Jeon, Hwa-Sung;Lee, Kyung-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.6
    • /
    • pp.602-609
    • /
    • 2011
  • In this paper, we standardized the water operation system picture, process control logic, realtime database and system configuration. All aspects, including monitoring & controlling processes, symbols such as pumps, valves and pipes were standardized. As a result we have developed a specialized Integrated water operation system, iWater. We have developed a variety of advanced application programs that are essential for water treatment systems, such as IWS (Integrated Warning system), MBO(modbus opc)/LSE(LS ethernet) driver, video monitoring, self diagnosis system, network monitoring, etc. IWS prevents water supply accidents by using a variety of alarms and warning messages. Drivers have the flexibility to communicate with other 3rd party systems. We expect that iWater will eliminate any concerns regarding water-related issues while also promoting the production and fair distribution of clean water.

Smart Factory using IoT based on Wi-SUN (Wi-SUN 기반 IoT 활용 스마트 팩토리)

  • Kim, Dongwon;Yoon, Mi-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.522-523
    • /
    • 2022
  • In this paper, we design a gateway protocol architecture for building an IoT-based smart factory. A smart factory system consists of several terminal devices, gateways and servers, and connects them through a wireless network. The terminal device collects information from various sensors and transmits the information to the server through the gateway. The terminal device controls the actuator by receiving a control signal according to a control algorithm of the server or by manual operation. Therefore, the gateway system connects Wi-SUN, a wireless smart utility network, and the Internet, serves as a Wi-SUN coordinator, and is equipped with Modbus-TCP to interwork with SCADA.

  • PDF

Design of Inner Section Displacement Measurement System Using Multiple Node Networks (다중 노드 네트워크를 이용한 내공변위 계측 시스템)

  • 서석훈;우광준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.20-26
    • /
    • 2001
  • In this paper, we design tunnel inner section displacement measurement system which is composed of potentiometer-type displacement sensors, microcontroller-based intelligent sensing head and host computer for the management system and acquisition data. Multiple node communication bus connects the intelligent sensing heads with the host computer. For safe and re1iab1e network operation we use daisy-chain configuration, termination resistor, fail-safe biasing circuit. For tole enhancement of system utilization, we use modbus protocol. The acquisition data are transmitted to host computer and managed by database. Several data request conditions and sorting conditions are provided by management software. The utilization of designed system is confirmed by experiment.

  • PDF

Vacuum Gauge Control System Using MSCC for PLS (MSCC를 이용한 가속기 진공장치 감시 시스템 개발)

  • Yoon, J.C.;Lee, T.Y.;Hang, J.Y.;Nam, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2169-2171
    • /
    • 2001
  • The vacuum gauge control system has been designed and implemented using multi-serial communication controllers (MSCC) for the 2.5 Gev storage ring at the Pohang Accelerator Laboratory (PAL). There are 20 Balzers vacuum gauges and 17 Granville-Phillips vacuum gauges at the storage ring. A MSCC have two RS485 (max speed 460.8Kbps) field network port, 8 channel serial communication ports (max speed 460.8Kbps) connected to gauge controller for serial communication control. 12 MSCCs are connected to a personal computer (PC) through the RS485 field network. The PC can automatically control the MSCCs by sending set of commands through the network. The commands specify the duration of the MODBUS protocol. Upon receiving a command from a PC running under Windows2000 through the network, the MSCC communicate through the serial output ports to gauge controller. In this paper, we describe control structure and scheme of the vacuum gauge control system.

  • PDF

Web-based Building Automation System using Embedded Linux (임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템)

  • 신은철;이수영;최병욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.