• Title/Summary/Keyword: Mn3s

Search Result 1,299, Processing Time 0.036 seconds

Biosorption and Desorption of Heavy Metals using Undaria sp. (미역 폐기물의 중금속 흡탈착 특성)

  • Cho, Ju-Sik;Park, Il-Nam;Heo, Jong-Soo;Lee, Young-Seak
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.92-98
    • /
    • 2004
  • The adsorption and desorption of Pb, Cd, Co, Zn, Cr, Co, Ni, and Mo on the waste Undaria sp. were studied. Except for Pb. the mono adsorption rate for all heavy metals were lower than that of the heavy metals mixed. However, the adsorption capacity of the heavy metals by 1g of biosorption, in mixed heavy metals increased According to FT-IR analysis of the biosorbent after heavy metal biosorption, the replacement of the functional group by the heavy metals ions could be confirmed and the inverted peaks became larger after heavy metals adsorption. The adsorption equilibrium of heavy metals was reached in about 1 hour. The equilibrium parameters were determined based on Langmuir and Freundlich isotherms. The affinity of metals on the biosorbent decreased in the following order: Pb>Cu>Cr>Cd>Co. The desorption rate decreased in the following sequence: NTA>$H_2SO_4$>HCl>EDTA. The desorption rate of heavy metals by NTA increased with increase in the concentration from 0.1 to 0.3% but the desorption rate became constant beyond 0.3%. Therefore, it represented that desorption rate of heavy metals was suitable under optimized condition ($30^{\circ}C$, pH 2 and 0.3% NTA solution) and was fast with 80% or more the uptake occurring within 10 min of contact time.

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

The Optimal Combination of Major Nutrients Computed by the Homès Systematic Variation Technique II. Determination of the Optimal Combination of Cations K:Ca:Mg in Fertilization on the Various Grassland Soils (Homes 방법(方法)에 의(依)한 다량요소(多量要素)의 적정시용(適正施用) 비율(比率) 결정(決定)에 관(關)한 연구(硏究) II. 초지토양별(草地土壤別) 음(陰)이온 N : Ca : Mg 적정시용(適正施用) 비율(比率))

  • Jung, Yeun-Kyu;Yoon, Sang-Gi;Weinberger, P.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.14 no.1
    • /
    • pp.37-43
    • /
    • 1981
  • This pot experiment was conducted to find out the optimal fertilization ratio of the cations(K: Ca: Mg) in various soil conditions. Soil samples were collected from uncultivated mountains and hills where development for grass lands is under consideration. The optimum ratios were computed by the Homes systematic variation technique. The results were summarized as follows : 1. The optimum fertilization ratios of the cations (K : Ca : Mg) for the high yields of grass-clover mixed sward at various areas were obtained (Table 4) 2. The relatively high optimum fertilization ratios of K in Daegu and Taegwalryong, Ca in Unbong, and Mg in Cheju district gave the high yields of clover in mixed sward. They were positively related to the low contents of the above cations in the soils or the relatively low content ratio comparing with other cations. 3. The yields of clover in mixed sward were seriously affected by the changes in both the fertilization ratio and total concentration of cations comparing to those of the grass yields. As a consequence, total yields, quality, and botanical composition of the mixed sward were also affected. 4. The antagonis among the cations K, Ca, and Mg was known from the point of mineral contents of grass and clover. 5. The equivalent ratio K/(Ca+Mg) or grass was greatly increased by the range of 2.4 and 3.3 in the K-group treatment, which was higher than the critical level 2.2 of grass tetany, otherwise that. of clover by the range of 0.9 and 1.2. Therfore, it may be concluded that if the botanical composition of grass/legume sward is optimum, the incidence of grass tetany can be eliminated.

  • PDF

Physicochemical characteristics of garlic (Allium sativum L.) shoots from different areas in Namhae (남해지역 마늘종의 이화학적 특성)

  • Yoon, Hwan-Sik;Kang, Min-Jung;Hwang, Cho-Rong;Sim, Hye-Jin;Kim, Gyeong-Min;Shin, Jung-Hye
    • Food Science and Preservation
    • /
    • v.21 no.3
    • /
    • pp.321-327
    • /
    • 2014
  • This paper introduces the physicochemical characteristics of garlic shoots investigated in the 8 areas of Namhae, Gohyeon-myeon (GHM), Nam-myeon (NM), Samdong-myeon (SDM), Namhae-eup (NHE), Seo-myeon (SM), Seolcheon-myeon (SCM), Idong-myeon (IDM) and Changsoen-myeon (CSM). The moisture was $80.15{\pm}0.37{\sim}83.87{\pm}0.15g/100g$. The crude protein and lipid were $1.59{\pm}0.02{\sim}2.25{\pm}0.09g/100g$ and $0.35{\pm}0.01{\sim}0.48{\pm}0.03g/100g$, respectively. Ash was $0.65{\pm}0.03{\sim}0.71{\pm}0.03g/100g$. In addition, the total levels of phenol and flavonoid were searched as $33.02{\pm}1.78{\sim}58.41{\pm}1.08mg/100g$ and $11.60{\pm}3.36{\sim}23.95{\pm}2.04mg/100g$, respectively. The garlic shoots in IDM, where the highest total chlorophyll level detected as $170.58{\pm}1.04{\mu}g/g$ and in CSM, where the lowest total chlorophyll level investigated as $116.65{\pm}0.00{\mu}g/g$, were unveiled. The mineral elements (S, Ca, Fe, K, Mg, Na, Mn and Zn) were analyzed by ICP-OES, and K was the most highly contained mineral with $7257.0{\pm}87.9{\sim}10070.0{\pm}9.7mg/kg$. Significant feature of garlic shoots in IDM and NHE was that the total amounts of mineral were relatively higher than other regions as 21,143.5 mg/kg and 20,581.2 mg/kg, respectively. The cultivating regions were revealed as the one of important matters with the level of allicin ($78.03{\pm}6.15{\sim}203.43{\pm}18.47mg/kg$). In particular, the level of allicin of garlic raised in SDM ($203.43{\pm}18.47mg/kg$) was approximately 2.2~2.6 times higher than those in CSM ($92.86{\pm}8.70mg/kg$) and SCM ($78.03{\pm}6.15mg/kg$). The sulfur compounds content of diallyl trisulde was remarkably higher, especially the garlic shoots in IDM with $830.62{\pm}14.69{\sim}1281.10{\pm}27.71mg/kg$.

A LONGITUDINAL STUDY ON THREE FACIAL GROWTH PATTERNS IN KOREANS WITH NORMAL OCCLUSION (정상교합자의 3가지 안면골 성장양상에 관한 누년적 연구)

  • Park, Krung-Duk;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.273-286
    • /
    • 1995
  • The purpose of this study was to compare the difference of the growth aspects in three facial growth patterns. The biennial serial cephalometric radiographs of 33 samples(19males, 14females) with normal occlusion from 8.5 years to 18.5 yews of age were used in this study. The facial growth patterrn was categorized in 3 types(Drop type, Neutral type, Forward type) by the total amounts of the Y-axis which changed from 8.5 years to 18.5 years of age. The growth change of the craniofacial area during 10 years in each growth type was analyzed and was compared among the 3 growth types. The results of this study might be summarized as follows. 1. The samples that were classified by total change of the Y-axis during this study period were distributed to 52% of the neutral type, 27% of the forward type, 21% of the drop type. 2. The anterior growth of the maxilla to the cranial base(N per A) showed larger in the forward type than in other 2 types(p<0.05). 3. The palatal plane to the FH plane showed more anterior-superior inclination in the forward type with age during this study period. 4. The anterior growth of the mandible to the cranial base(N per Pog) appeared large in rank order, of largest the forward type, second the neutral type, and third the drop type(p<0.05). 5. During this study period the mandibular plane(SN/MN,FMA) showed more counterclockwise rotation in the forward type than in the drop type(p<0.05), and this tendency was stronger in males than in females(p<0.05). 6. The growth of the mandibular corpus length(Go-Me) showed smaller in the drop type than in the other 2 types(p<0.05). 7. In the forward type and the neutral type, the anterior growth of the mandible was larger than that of the maxilla(p<0.05). 8. In the craniofacial growth distances and angulations turned out to be somewhat variable, but the vertical proportion had a strong tendency whose original relation was maintained consistently during this study period. 9. Through these analyzed data, the profilograms on each growth type were constructed to evaluate individual growth pattern in the orthodontic diagnosis.

  • PDF

Development of Anode-supported Planar SOFC with Large Area by tape Casting Method (테입캐스팅을 이용한 대면적 (100 cm2) 연료극 지지체식 평판형 고체산화물 연료전지의 개발)

  • Yu, Seung-Ho;Song, Keun-Suk;Song, Hee-Jung;Kim, Jong-Hee;Song, Rak-Hyun;Jung, Doo-Hwan;Peck, Dong-Hyun;Shin, Dong-Ryul
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.1
    • /
    • pp.41-47
    • /
    • 2003
  • For the development of low temperature anode-supported planar solid oxide fuel cell, the planar anode supports with the thickness of 0.8 to 1 mm and the area of 25, 100 and $150\;cm^2$ were fabricated by the tape casting method. The strength, porosity, gas permeability and electrical conductivity of the planar anode support were measured. The porosity of anode supports sintered at $1400^{\circ}C$ and then reduced in$H_2$ atmosphere was increased from $45.8\%\;to\;53.9\%$. The electrical conductivity of the anode support was $900 S/cm\;at\; 850^{\circ}C$ and its gas permeability was 6l/min at 1 atm in air atmosphere. The electrolyte layer and cathode layer were fabricated by slurry dip coating method and then had examined the thickness of $10{\mu}m$ and the gas permeability of 2.5 ml/min at 3 atm in air atmosphere. As preliminary experiment, cathode multi-layered structure consists of LSM-YSZ/LSM/LSCF. At single cell test using the electrolyte layer with thickness of 20 to $30{\mu}m$, we achieved $300\;mA/cm^2$ and 0.6V at $750^{\circ}C$

Comparison of the retention of the full veneer casted gold crowns with varying convergence angle, crown length and dental cements (수렴각과 치관 길이를 달리한 금속 다이상에서 치과용 시멘트 합착 후 전부주조관의 유지력 비교)

  • Yun, Jung-Ho;Cho, Jin-Hyung;Kim, Jee-Hwan;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • Purpose: The aim of this research was to establish the effect and variation in differing convergence angle and length of abutment on the retention of full veneer casted gold crown. Materials and methods: Two different length,5 mm and 10 mm in height with convergence angles of 5, 10, 15 and 25 degrees crowns were fabricated. Cementation was done using cements; zinc phosphate cement (Fleck's zinc phosphate cement), resin-modified glass ionomer cement (Vitremer) and resin cement (Panavia 21). These were tested for tensile force at the point of separation by using Instron Universal Testing Machine. Statistical analysis was done by SAS 6.04 package. Results: In all cements the mean retention decreased with significant difference on increase of convergence angle (P<.05). Increase in every 5 degree-convergence angel the retention rate decreased with resin-modified glass ionomer cement of 15.9% and resin cement of 14.8%. With zinc phosphate cement, there was largest decreasing rate of mean retention of 25.5% between convergence angles from 5 degree to 10 degree. When the crown length increased from 5 mm to 10 mm, the retention increased with the significant difference in the same convergence angle and in all types of cement used (P<.05). Conclusion: The retention was strongly dependent on geometric factors of abutment. Much care is required in choosing cements for an optimal retention in abutments with different convergence angles and crown lengths.

Analysis of Micronuclei and Its Association with Genetic Polymorphisms in Hospital Workers Exposed to Ethylene Oxide (에틸렌옥사이드(Ethylene oxide)에 노출된 병원 근로자들의 소핵 빈도와 유전적 감수성 지표와의 연관성)

  • Lee, Sun-Yeong;Kim, Yang-Jee;Choi, Young-Joo;Lee, Joong-Won;Lee, Young-Hyun;Shin, Mi-Yeon;Kim, Won;Yoon, Chung-Sik;Kim, Sung-Kyoon;Chung, Hai-Won
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.429-439
    • /
    • 2011
  • Objectives: Ethylene oxide (EtO) is classified as a human carcinogen, but EtO is still widely used to sterilize heat-sensitive materials in hospitals. Employees working around sterilizers are exposed to EtO after sterilization. The aim of the present study was to assess the exposure of EtO level, coupled with occupationally induced micronuclei from hospital workers. The influence of genetic polymorphisms of detoxifying genes (GSTT1 and GSTM1) and DNA repair genes (XRCC1 and XRCC3) on the frequencies of micronuclei in relation to exposure of EtO was also investigated. Methods: The study population was composed of 35 occupationally exposed workers to EtO, 18 student controls and 44 unexposed hospital controls in Korea. Exposure to EtO is measured by passive personal samplers. We analyzed the frequencies of micronuclei by performing cytokinesis-block micronucleus assay (CBMN assay) and GSTM1, GSTT1, XRCC1, and XRCC3 were also genotyped by performing polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Results: The frequencies of micronuclei in EtO exposure group, student controls and hospital controls were $18.00{\pm}7.73$, $10.47{\pm}7.96$ and $13.86{\pm}6.35$ respectively and their differences were statistically significant, but no significant differences according to the level of EtO were observed. There was a dose-response relationship between the frequencies of micronuclei and cumulative dose of EtO, but no significantly differences were observed. We also investigated the influence of genetic polymorphisms (GSTM1, GSTT1, XRCC1, and XRCC3) on the frequencies of micronuclei, but there were no differences in the frequencies of micronuclei by genetic polymorphisms. Conclusions: The frequencies of micronuclei in EtO exposure group was significantly higher than control groups. A dose-response relationship was found between the level of EtO exposure and the frequencies of micronuclei, but no statistically differences were observed. We also found that the frequencies of micronuclei were increased according to cumulative EtO level. There was no association of the genetic GSTM1, GSTT1, XRCC1, and XRCC3 state with the frequency of micronuclei induced by EtO exposure.

A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications (구치용 도재소부금관과 전부도재관에 파절을 일으키는 한국음식에 관한 연구)

  • Kim, Jeong-Ho;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Statement of problem: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. Purpose: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. Material and methods: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load(N) was recorded. Afterwards, selected Korean foods specimens(boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental ceramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. Results: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load(14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8-9321.2 cycles under 2224.8 N(round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1-1143565.7 cycles under 2224.8 N(round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0-1145773.4 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1-954.7 cycles under 382.9 N(boiled chicken with bone). no fracture under smaller loads. Conclusion: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown(full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy(2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy(2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone(382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone(382.9 N).

The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching (산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도)

  • Kim, You-Lee;Kim, Jee-Hwan;Shim, June-Sung;Kim, Kwang-Mahn;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.148-156
    • /
    • 2008
  • Statement of problems: Self-etch adhesives exhibit some clinical benefits such as ease of manipulation and reduced technique-sensitivity. Nevertheless, some concern remains regarding the bonding effectiveness of self-etch adhesives to enamel, in particular when so-called 'mild' self-etch adhesives are employed. This study compared the microtensile bond strengths to ground enamel of the two-step self-etch adhesive Clearfil SE Bond (Kuraray) to the three-step etch-and- rinse adhesive Scotchbond Multi-Purpose (3M ESPE) and the one-step self-etch adhesive iBond (Heraeus Kulzer). Purpose: The purpose of this study was to determine the effect of a preceding phosphoric acid conditioning step on the bonding effectiveness of a two-step self-etch adhesive to ground enamel. Material and methods: The two-step self-etch adhesive Clearfil SE Bond non-etch group, Clearfil SE Bond etch group with prior 35% phosphoric acid etching, and the one-step self-etch adhesive iBond group were used as experimental groups. The three-step etch-and-rinse adhesive Scotchbond Multi-Purpose was used as a control group. The facial surfaces of bovine incisors were divided in four equal parts cruciformly, and randomly distributed into each group. The facial surface of each incisor was ground with 800-grit silicon carbide paper. Each adhesive group was applied according to the manufacturer's instructions to ground enamel, after which the surface was built up using Light-Core (Bisco). After storage in distilled water at $37^{\circ}C$ for 1 week, the restored teeth were sectioned into enamel beams approximately 0.8*0.8mm in cross section using a low speed precision diamond saw (TOPMET Metsaw-LS). After storage in distilled water at $37^{\circ}C$ for 1 month, 3 months, microtensile bond strength evaluations were performed using microspecimens. The microtensile bond strength (MPa) was derived by dividing the imposed force (N) at time of fracture by the bond area ($mm^2$). The mode of failure at the interface was determined with a microscope (Microscope-B nocular, Nikon). The data of microtensile bond strength were statistically analyzed using a one-way ANOVA, followed by Least Significant Difference Post Hoc Test at a significance level of 5%. Results: The mean microtensile bond strength after 1 month of storage showed no statistically significant difference between all adhesive groups (P>0.05). After 3 months of storage, adhesion to ground enamel of iBond was not significantly different from Clearfil SE Bond etch (P>>0.05), while Clearfil SE Bond non-etch and Scotchbond Multi-Purpose demonstrated significantly lower bond strengths (P<0.05), with no significant differences between the two adhesives. Conclusion: In this study the microtensile bond strength to ground enamel of two-step self-etch adhesive Clearfil SE Bond was not significantly different from three-step etch-and-rinse adhesive Scotchbond Multi-Purpose, and prior etching with 35% phosphoric acid significantly increased the bonding effectiveness of Clearfil SE Bond to enamel at 3 months.