• Title/Summary/Keyword: Mn removal efficiency

Search Result 157, Processing Time 0.032 seconds

Enhancement of phosphate removal using stabilized Fe-Mn particle (Fe-Mn 입자의 안정화를 통한 인산염 효율 향상)

  • Seoyeon Kang;Jeongwoo Shin;Byugnryul An
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.375-382
    • /
    • 2023
  • The binary oxide adsorbent using Fe and Mn (Fe-Mn) has been prepared by precipitation method to enhance the removal of phosphate. Different amounts of chitosan, a natural organic polymer, were used during preparation of Fe-Mn as a stabilizer to protect an aggregation of Fe-Mn particles. The optimal amount of chitosan has been determined considering the separation of the Fe-Mn particles by gravity from solution and highest removal efficiency of phosphate (Fe-Mn10). The application of Fe-Mn10 increased removal efficiency at least 15% compared to bare Fe-Mn. According to the Langmuir isotherm model, the maximum uptake (qm) and affinity coefficient (b) were calculated to be 184 and 240 mg/g, and 4.28 and 7.30 L/mg for Fe-Mn and Fe-Mn10, respectively, indicating 30% and 70% increase. The effect of pH showed that the removal efficiency of phosphate was decrease with increase of pH regardless of type of adsorbent. The enhanced removal efficiency for Fe-Mn10 was maintained in entire range of pH. In the kinetics, both adsorbents obtained 70% removal efficiency within 5 min and 90% removal efficiency was achieved at 1 h. Pseudo second order (PSO) kinetic model showed higher correlation of determination (R2), suggesting chemisorption was the primary phosphate adsorption for both Fe-Mn and Fe-Mn10.

Evaluation of Mn Removal Efficiency from the Mine Drainage in the Presence of Fe Using Slag Complex Reactors (제강슬래그 복합매질체를 이용한 철 유입에 따른 광산배수내 망간 제거효율 평가)

  • Kim, Dong-Kwan;Ji, Won Hyun;Kim, Duk-Min;Park, Hyun-Sung;Oh, Youn Soo
    • Economic and Environmental Geology
    • /
    • v.51 no.5
    • /
    • pp.401-407
    • /
    • 2018
  • For the treatment of heavy metals in the mine drainage from the closed mine area, various methods such as passive, active and semi-active treatments are considered. Among contaminated elements in the mine drainage, Mn is one of the difficult elements for the treatment because it needs high pH over 9.0 for its concentration to be reduced. In this study, the efficiency of various slag complex reactors (slag (S), slag+limestone (SL) and slag+Mn coated gravel (SG)) on Mn removal in the presence of Fe, which is a competitive element with Mn, was evaluated to investigate effective methods for the treatment of Mn in mine drainage. As a result of experiments on Mn removal without Fe during 358 days, using influent with $30{\sim}50Mn{\cdot}mg/L$ and pH 6.7 on the average, S reactor showed continuously high Mn removal efficiency with the average of 99.9% with pH 8.9~11.4. Using the same reactors, Mn removal experiments with Fe during 237 days were conducted with the influent with $40{\sim}60Mn{\cdot}mg/L$. The pH range of effluent reached to 6.1~10.0, which is slightly lower than that of effluent without Fe. S reactor showed the highest range of pH with 7.1~9.9, followed by S+L and S+G reactor. However, the efficiency of Mn removal showed S+L>S>S+G with the range of 94~100%, 68~100% and 68~100%, respectively in spite of relatively low pH range. S+L reactor showed the most resistance on Fe input, which means other mechanisms such as $MnCO_3$ formation by the carbonate prouced from the limestone or autocatalysis reaction of Mn contributed to Mn removal rather than pH related mechanisms. The evidence of reactions between carbonates and Mn, rhodochrosite ($MnCO_3$), was found from the X-ray diffraction analysis of precipitates sample from S+L reactor. From this study, the most effective reactors on Mn removal in the presence of Fe was S+L reactor. The results are expected to be applied for the Mn containing mine water treatment in the presence of Fe within the relatively low range of pH.

A Study on the Characteristics of Pollutant Removal in Secondary Effluent from Wastewater Treatment Plant Using Silver Nanoparticles on Activated Carbon (은나노 활성탄에 의한 하수 2차 처리수 중의 오염물질 제거 특성에 관한 연구)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.29 no.5
    • /
    • pp.353-360
    • /
    • 2014
  • This study targets the pollutant removal of secondary effluent from final clarifiers in wastewater treatment plant using silver nanoparticles on activated carbon. The removal efficiency and treatment characteristics of pollutant are anlayzed by perfoming experiments using granular activated carbon with silver nanoparticles and ordinary granular activated carbon. The specific surface area of granular activated carbon with silver nanoparticles is smaller than that of ordinary granular activated carbon. However, the removal efficiency of $COD_{Mn}$, T-N and T-P in experiments using activated carbon with silver nanoparticles are higher than that in experiment using ordinary granular activated carbon. That means the case of activated carbon with silver nanoparticles is much better at treatment activity. In addition, activated carbon with silver nanoparticles has antimicrobial activity because there is no microbe on the surface of it after experiments.

Removal of Manganese(II) from Aqueous Solution Using Manganese Coated Media (망간코팅 여재를 이용한 수용액상의 망간 제거연구)

  • Kim, Seok-Jun;Kim, Won-Gee;Lee, Seung-Mok;Yang, Jae-Kyu
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.454-459
    • /
    • 2010
  • This study investigated the applicability of manganese coated media such as manganese coated sand (MCS), manganese coated sericite (MCSe) and manganese coated starfish material calcined at $550^{\circ}C$ (MCSf) to remove Mn(II) in synthetic wastewater. Manganese coated media prepared at different pH was applied in the treatment of soluble Mn(II) in batch and column experiments at various Mn(II) concentrations. The amount of Mn coated on three different media was approximately 800~1100 mg/kg. From the stability test, negligible dissolution of Mn was observed above pH 3.0. In batch test, more than 40% of Mn(II) was removed by all sand media at various manganese concentrations. In order to see the effect of additional oxidant for the removal of Mn(II), 4 mg/L of hypochlorite was added in Mn(II) solution during column experiment. Breakthrough of Mn(II) was greatly retarded in the presence of hypochlorite in all column reactors packed with different media. Among the manganese coated media, MCSf prepared at pH 4 indicated the highest removal capacity. The removal efficiency of Mn(II) was also increased in the multi-layer system (0.5 g of MCS, MCSe, and MCSf each).

Recycling of Biological Industrial Waste as an Adsorbent for Heavy Metals (중금속 제거를 위한 흡착제로서 생물산업 폐기물의 재활용)

  • 장재선;이제만;김용희
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.3
    • /
    • pp.7-13
    • /
    • 2002
  • The removal efficiency of heavy metals by chitosan complex isolated from biological industrial waste was investigated through laboratory experiments. The results of the study are as follows. The adsorption kinetics of heavy metals were reached the equilibrium adsorption in approximately 30 minutes and the removal efficiency were showed 70.7~97.4%. The effect of temperature on heavy metals adsorption by chitosan complex shows that as the temperature increased, the amount of heavy metals adsorption per unit weight of chitosan complex increased. The correlation between amount of heavy metals adsorption per unit weight of chitosan complex and temperature were obtained through the coefficient of determination($R^2$). $R^2$ values were 0.75(p<0.05), 0.99(p<0.05) and 0.98(p<0.05) in Hg, Mn, and Zn, respectively. The injected chitosan complex in which 0.1 g was adsorpted highly and the removal of heavy metals was found to have the best removal efficiency A linearized Freundlich equation was used to fit the acquired experimental data. As a result, Freundlich constants, the adsorption intensity(I/n) was 0.5564, 0.4074, 0.5244 on the Hg, Mn, Zn, respectively And the measure of adsorption(k) was 2.2144, 1.6963, 2.0792 on the Hg, Mn, Zn, respectively. So, it was concluded that adsorption of heavy metals by chitosan complex is effective.

NOx removal of Mn-Cu-TiO2 catalyst for the calcination and oxygen concentration conditions (소성 및 산소농도 조건에 대한 Mn-Cu-TiO2 촉매의 탈질 특성)

  • Jang, Hyun Tae;Cha, Wang Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.900-905
    • /
    • 2015
  • DeNOx catalysts composed of Mn, Cu and $TiO_2$ were prepared and tested for $NH_3$-SCR. The performance of each catalyst was studied for the NOx removal efficiency while changing the calcination temperature, reaction time, and oxygen concentration. The hydrogen conversion efficiency of a calcined catalyst was measured at the $H_2$-TPR system. The change in the specific surface area of catalyst according to the calcination temperature was analyzed. As a result, the proper calcination temperature was approximately $300^{\circ}C$. If the calcination temperature is increased to $500^{\circ}C$, the NOx removal efficiency of Mn and Cu constituents is largely decreased at the low temperature range. Oxygen in flue gas is an important parameter in the SCR reaction and optimal oxygen concentration is approximately 8 vol.%.

Removal Characteristics of Iron, Manganese and Organics in Ground Water Using Ozonation (오존을 이용한 지하수의 철.망간 및 유기물 제거특성)

  • 선창욱;우달식;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.43-49
    • /
    • 1997
  • Iron and manganese problems in ground water affect far more water systems than almost any other water quality concern. The purpose of this study is to find the optimum condition of ozonation for the removal of dissolved iron, manganese and other organics in the polluted ground water. We proposed 4mg/l, 8mg/l as optimum ozone dose for the removal of $Fe^{2+},{\;}Mn^{2+}$, respectively. The removal efficiencies of $COD_{Mn}$ and $COD_{Cr}$ in ozone dose of 2mg/l - 6mg/l were about 40-50%. The removal efficiency of $NH_{3}-N$ was about 30-40% at pH8.5. In conclusion, it needs further systematic study and research concerned to treatability of $Fe^{2+},{\;}Mn^{2+}$ and biodegradability of organic compounds using Ozonation followed by biological filtration process in ground water treatment train.

  • PDF

The Removal of Organics, Nitrogen and Phosphorus in Loop Reactor Using Fluidized Media (유동상 담체를 이용한 Loop Reactor에서 유기물 및 질소, 인 제거)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.353-360
    • /
    • 2009
  • This study was accomplished using Anaerobic/Anoxic/Oxic upflow packed-bed column reactors with fixed media and Loop Reactor with fluidized media instead of Oxic reactor. The objectives of this study was to investigate the characteristics of organics, nitrogen and phosphorus removal from sewage with the HRT. The average removal efficiencies of $BOD_5$ and SS increase as increasing the hydraulic retention time (HRT) until 16 h of the HRT, and they were constant over 16 h of the HRT. The removal efficiency of $BOD_5$ in case of packed-bed reactor and Loop Reactor was about 86.6% and 90.9% respectively at 16 h of the HRT. The removal efficiency of SS in packed-bed reactor and Loop Reactor was about 78.0% and 88.2% respectively at 16 h of the HRT. The average removal efficiencies of $COD_{Cr}$ and $COD_{Mn}$ showed similar trends as those of $BOD_5$ and SS. At the HRT of 16 h, the removal efficiency of $COD_{Cr}$ in case of packed-bed reactor and Loop Reactor was 63.5%, 75.2% and that of $COD_{Mn}$ was 60.7%, 73.6% respectively. The average removal efficiencies of T-N and T-P increase as increasing the HRT. The removal efficiencies of T-N and T-P in Loop Reactor were 33.6% and 54.5% respectively at 16 h of the HRT and T-N and T-P were better removed in Loop Reactor. From this result, it was found that the performance of Loop Reactor was much higher than the performance of packed-bed reactor and the optimum HRT was 16 h.

Reaction Mechanism of Low Temperature NH3 SCR over MnOx/Sewage Sludge Char (MnOx/Sewage Sludge Char를 이용한 저온 NH3 SCR의 반응 메커니즘)

  • Cha, Jin-Sun;Park, Young-Kwon;Park, Sung Hoon;Jeon, Jong-Ki
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.308-311
    • /
    • 2011
  • The reaction mechanism of selective catalytic reduction of NOx over sewage sludge char impregnated with MnOx using $NH_3$ as the reducing agent was investigated. The active Mn phase was shown to be $Mn_3O_4$ from the XRD analysis. Adsorption was the dominant NOx removal mechanism at low temperatures below $150^{\circ}C$ although reduction reaction also contributed partly to the NOx removal at $100{\sim}150^{\circ}C$. The reaction rate constants of NOx removal over non-impregnated and MnOx-impregnated active chars were compared based on experimental results. The MnOx-impregnated char was shown to have a higher reaction rate constant and a higher NOx removal efficiency due to a higher collision coefficient and a lower activation energy. The activation energy for both chars was shown to be relatively low (10~12 kJ/mol) under the experimental conditions of this study.

A Study on the Removal of Refractory Organic Matter in Leachate sampled at Kimpo Landfill by means of Fenton Oxidation Process (Fenton 산화를 이용한 김포매립지 침출수내 난분해성)

  • 정동환;조일형;김익수;한인규;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.26 no.4
    • /
    • pp.49-57
    • /
    • 2000
  • This study was carried out to find the optimal condition to treat refractory organic matter which can’t treat clearly with biological treatment and to find the optimal division dosage and division dose timing in the modification of Fenton oxidation which is used resolve the problem that hydrogen peroxide is too expensive. The results are following; 1. The highest TOC removal efficiency was 41% and color removal efficiency was 64% when the dilution magnitude of leachate is fold. This suggests that dilution is efficiency when high concentration of leachate is treated. 2. The removal efficiency of TOC and color increased up to the molar ratio between ferrate and hydrogen peroxide was 1:1. However above that ratio, removal efficiency hardly increased. The highest removal efficiency of TOC and color were 38% and 71% when the mole ratio of ferrate to hydrogen peroxide was 1.5:1. 3. When the mole ratio between ferrate and hydrogen peroxide was fixed, the removal efficiency of TOC and color increased as the dosage of hydrogen peroxide increased. 4. pH of samples were adjusted at pH 3, 5, 7, 9, 11. After oxidation reaction, pH of samples were dropped to 2.59, 2.54, 5.34, 6.36 and 9.68. The highest color removal efficiency was 75.7% when initial pH was at pH 7. 5. The removal of TOC and color was ended within 10. min. and the removal efficiency increased logarithmically within 10min. However after 10 min., the removal efficiency of hardly increased. 6. The color removal efficiency was higher with modification of fentone oxidation than that with fentone oxidation by 5%. Optimal division dosage ratio was 1:1 and optimal dose timing ratio was 2:1. However the TOC removal efficiency was not higher with modification of Fenton oxidation than that with Fenton oxidation.7. The CO $D_{Mn}$ /BO $D_{5}$ Ratio decreased with the time went by. It meant bioresolution increased as time went by. However, after 15 min., the CO $D_{Mn}$ /BO $D_{5}$ Ratio did not decrease any more. 8. In the case of $H_2O$$_2$ Divisiom Dose experiment, the increase of bioresolution was highest at the $H_2O$$_2$ Division dosage Ratio of 3:7.3:7.

  • PDF