• 제목/요약/키워드: Mixed concrete

검색결과 1,164건 처리시간 0.027초

설계기준 압축강도별 레미콘의 염소이온 확산 특성평가 (Chloride Ion Diffusion for Ready Mixed Concrete)

  • 박동천;김용로
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2018
  • The RC buildings which are constructed on the seaside are followed by KBC(2016) to achieve the minimization of durability damage. To control the corrosion of the reinforced steel bar by salt attack, W/C should be under 0.4 and specified concrete strength is more than 35MPa in the concrete/building construction standard specification. Ready mixed concretes which have usually include the admixtures in Busan were tested to certify the salt attack durability. In the same specified concrete strength, remarkable salt attack durability was evaluated in comparison to OPC.

  • PDF

Behavior factors for mixed reinforced concrete wall and buckling restrained braced frame

  • Hamid Beiraghi;Behdad Abbaspour
    • Structural Engineering and Mechanics
    • /
    • 제86권2호
    • /
    • pp.277-290
    • /
    • 2023
  • A supplementary reinforced concrete wall can be used to improve the seismic behavior of a buckling restrained braced frame as a mixed system. In such a novel system, the total lateral force is resisted by the combination of the RC wall system and the BRBF. There is not enough research on the response modification factor of such a mixed system. This paper investigates the response modification factor, and such relevant factors as ductility reduction factor and over strength factor for a system consisting of reinforced concrete wall and buckling restrained braced frame. To this purpose, nonlinear incremental dynamic analysis as well as static push over analysis are used for 6- to 14-story sample structures. The results show that for mixed considered systems, the mean value of response modification factor varies approximately from 7 to 9.

염화물 오염 콘크리트 공극 용액에서 철근의 부식 억제에 대한 혼합 억제제의 효과 (Effect of Mixed Inhibitor on Corrosion Inhibition of Steel Rebar in Chloride Contaminated Concrete Pore Solution)

  • 소우멘 만달;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.32-33
    • /
    • 2021
  • The corrosion of the embedded steel rebars and the consequent deterioration of the reinforced concrete structure has become a challenging concern to the construction industries for the fiscal deficit. However, corrosion inhibitors are potential and being widely used for corrosion mitigation to solve such problems. This study has been focused on the mixed type of corrosion inhibitor where one component of the corrosion inhibitor is organic and another one is inorganic material. 0.1 (M) triethanolamine (TEA) and 0.01 (M) sodium hexametaphosphate (SHMP) have been mixed in distilled water to produce the mixed inhibitor. Studies of the steel rebar corrosion in chloride contaminated (3.5 wt.% NaCl) concrete pore (CCCP) solution has been conducted using different concentrations of corrosion inhibitor. Electrochemical impedance spectroscopy (EIS) method is involved to understand the corrosion behaviour of the steel rebars at different exposure durations.

  • PDF

카르본산계 고성능감수제를 첨가한 시멘트 모르타르의 유동 특성 (Flow and Strength Properties of Cement Mortar Mixed with High Range Water Reducer Containing Carboxylic Acid)

  • 김화중;강인규;권영도;김우성;황재현;김원기;박기청
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.142-147
    • /
    • 1995
  • In this study, styrene-maleic anhydride copolymer (SMA) was synthesized from styrene and maleic anhydride and further reacted with sulfuric acid to obtain water-soluble SMA and the flow and strength tests of cement mortar mixed with copolymers were carried out to evaluate the capability of copolymers as high range water reducer for the concrete. It was found from flow experiment that the fluidity of cement mortar mixed with sulfonated SMA (SSMA) was larger than that miced with aminophenol-substituted SSMA (SmSMA). The decreasing rate of the flow of cement mortar mixed with SSMA and SmSMA was decreasing rate of the flow of cement mortar mixed with SSMA and SmSMA was significantly lower than that mixed with naphthalene condensate (NSC). The compressive strength of the hardened cement mortars containing 0.5% copolymers after 28 days curing was examined. The compressive strength of hardened cement mortar containing SSMA and SmSMA was increased up to 32% and 13%, respectively, when compared to the plain. As the results, the copolymers (SSMA and SmSMA) used in this study are greatly expected as a good high range water reducers for the concrete.

  • PDF

Response modification factor of mixed structures

  • Fanaie, Nader;Shamlou, Shahab O.
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1449-1466
    • /
    • 2015
  • Mixed structures consist of two parts: a lower part and an upper part. The lower part is usually made of concrete while the upper part is made of steel. Analyzing these structures is complicated and code-based design of them has many associated problems. In this research, the seismic behavior of mixed structures which have reinforced concrete frames and shear walls in their lower storeys and steel frames with bracing in their upper storeys were studied. For this purpose, seventeen structures in three groups of 5, 9 and 15 storey structures with different numbers of concrete and steel storeys were designed. Static pushover analysis, linear dynamic analysis and incremental dynamic analysis (IDA) using 15 earthquake records were performed by OpenSees software. Seismic parameters such as period, response modification factor and ductility factor were then obtained for the mixed (hybrid) structures using more than 4600 nonlinear dynamic analysis and used in the regression analysis for achieving proper formula. Finally, some formulas, effective in designing such structures, are presented for the mentioned parameters. According to the results obtained from this research, the response modification factor values of mixed structures are lower compared to those of steel or concrete ones with the same heights. This fact might be due to the irregularities of stiffness, mass, etc., at different heights of the structure. It should be mentioned that for the first time, the performance and seismic response of such structures were studied against real earthquake accelerations using nonlinear dynamic analysis, andresponse modification factor was obtained by IDA.

레미콘의 품질확보 방안 및 콘크리트 기사 자격제도 (Plans to Improve the Quality of Ready-Mixed Concrete and a Auggestion of Legislating a Concrete Engineer Certification)

  • 박승범
    • 콘크리트학회지
    • /
    • 제14권4호
    • /
    • pp.14-21
    • /
    • 2002
  • 국내에서 시공되는 콘크리트 구조물의 대부분은 레미콘(ready-mixed concrete)으로 시공되고 있기 때문에 레미콘의 품질관리(quality control) 및 품질확보(quality security)는 곧 콘크리트 구조물의 품질과 내구성의 확보를 위해 매우 중요한 사항이다. 최근 콘크리트 구조물의 잦은 사고로 인해 콘크리트의 품질문제가 사회문제로 나타나고 있으며 이에 대비한 콘크리트 품질보증 시스템의 확립이 시급한 실정이다. 그러나 레미콘의 품질환경은 원재료의 품질저하, 레미콘 운반시간의 증대 및 기술개발의 미흡 등 주변여건이 좋은 편은 아니며 레미콘 산업도 경쟁시대에 돌입하면서 레미콘 품질이나 기술우위의 시대로 변화되고 있다.(중략)

신경망기법을 사용한 콘크리트의 배합요소 추정 (Prediction on the Proportioning of Concrete Mixes Using Neural Network)

  • 김종인;최영화;김인수
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.419-426
    • /
    • 2001
  • Concrete mix proportioning is a process of selecting the right combination of many materials such as cement, fine aggregates, coarse aggregates, water, and admixtures to make concrete satisfying for specification and cost. In determining proportioning of concrete mixes, code information, specification, and the experience of experts are needed. However, all factors regarding mix proportioning factor cannot be considered. Therefore, the final acceptance depends on concrete quality control test results. The proportioning of concrete mixes and the adjustments are somewhat complicated, time-consuming, and uncertain tasks. In this paper, as a tool to predict the factor of the proportioning of concrete mixes, an artificial neural network is used. To consider the varieties of material properties, the standard mixed table of two companies of ready mixed concrete are used. The results show that neural net works is successfully applied to the prediction of concrete mix proportioning factor.

  • PDF

섬유혼입 고강도 콘크리트의 열전달 및 역학적 거동 해석모델에 대한 연구 (Study on The Heat Transfer and Mechanical Modeling of Fiber-Mixed High Strength Concrete)

  • 신영섭;한동석;염광수;전현규
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.45-52
    • /
    • 2011
  • 고강도 콘크리트의 폭렬현상을 억제하여 내화 성능을 개선하기 위한 방법으로 고온에서 수증기가 콘크리트 표면으로 이동할 수 있도록 경로를 제공하여 주는 섬유를 혼입하는 방안이 있다. 본 연구에서는 섬유혼입 고강도 콘크리트 기둥에 대한 재하 내화 실험을 수행하였고, 내부 철근의 온도분포 예측을 위한 열전달 모델과 고온에서 콘크리트 기둥의 역학적 거동에 대한 재료모델을 제시하였다. 화재 시 콘크리트 내부의 물리적인 현상과 콘크리트의 열적 특성을 고려하여 선행 연구의 재료모델을 수정하였다. 수정한 모델을 이용한 섬유혼입 고강도 콘크리트의 유한요소 해석을 실행하였고, 재하 내화실험과의 비교를 통하여 재료모델을 제안하였다.

풍쇄슬래그 잔골재를 사용한 콘크리트의 공학적 특성에 관한 실험적 연구 (An Experimental Study on the Engineering Properties of Concrete using Fine Aggregate of PS ball Slag)

  • 이상수;송하영;김을용
    • 한국건축시공학회지
    • /
    • 제6권3호
    • /
    • pp.107-114
    • /
    • 2006
  • In this study, the experiment was carried out to investigate and analyze the engineering properties of concrete using fine aggregate of PS bal slagl. The main experimental variables were water/cement ratio 30, 40, 50(%), water content $170kg/m^3$, replacement ratio of slag fine aggregate 0, 25, 50, 75(%) in experiment I and water/cement ratio 30, 40, 50(%), water content 165, 170, 175($kg/m^3$), replacement ratio of fine aggregate of PS ball 0, 50 in experiment II. According to the test results, the principle conclusions are summarized as follows (1) The workability of slag fine aggregate-mixed concrete tends to improve, as the replacement rate increases. (2) The air content of slag fine aggregate-mixed concrete tends to decrease, as the replacement rate increases. (3) The unit volume weight of slag fine aggregate-mixed concrete tends to significantly increase, as the replacement rate increases. (4) The compressive strength of slag fine aggregate-mixed concrete tends to show more increasing propensity, in case the curing period is relatively long, as the replacement rate increases.

2000년과 2008년 4대 도시 레미콘 출하 현황(現況)을 통한 품질 변화(變化)에 관(關)한연구(硏究) (A study regarding a quality change through four 2000 and 2008 city ready mixed concrete shipment present situations)

  • 조도영;김종백;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 산업계
    • /
    • pp.65-68
    • /
    • 2009
  • Recently, the knowledge access about concrete might be 2 methods. One is approach about advanced and new technical development through the institute journal, the other is construction technology which is using at construction fields. However, there is no research for the interrelationship between them. So, this paper investigates the demands on construction fields at the ready mixed concrete plants on the 4 cities, the characteristics of the products like the maximum size of coarse aggregate and slump, and the extension of market on the high strength and flow ability concrete in 2000 and 2008. Moreover, this study would like to propose the investigation about diversification of construction materials for the fine construction cultures and development of the ready mixed concrete to the engineers at the construction fields.

  • PDF