• Title/Summary/Keyword: Mixed Convection

Search Result 130, Processing Time 0.027 seconds

An Immersed-Boundary Finite-Volume Method for Simulation of Heat Transfer in Complex Geometries

  • Kim, Jungwoo;Park, Haecheon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.1026-1035
    • /
    • 2004
  • An immersed boundary method for solving the Navier-Stokes and thermal energy equations is developed to compute the heat transfer over or inside the complex geometries in the Cartesian or cylindrical coordinates by introducing the momentum forcing, mass source/sink, and heat source/sink. The present method is based on the finite volume approach on a staggered mesh together with a fractional step method. The method of applying the momentum forcing and mass source/sink to satisfy the no-slip condition on the body surface is explained in detail in Kim, Kim and Choi (2001, Journal of Computational Physics). In this paper, the heat source/sink is introduced on the body surface or inside the body to satisfy the iso-thermal or iso-heat-flux condition on the immersed boundary. The present method is applied to three different problems : forced convection around a circular cylinder, mixed convection around a pair of circular cylinders, and forced convection around a main cylinder with a secondary small cylinder. The results show good agreements with those obtained by previous experiments and numerical simulations, verifying the accuracy of the present method.

Analysis of Natural Convection Heat Transfer from Electronic Modules in a Plasma Display Panel (플라즈마 영상장치의 채널 사이에 놓인 전자모듈의 자연대류 열전달 해석)

  • Choi, In-Su;Park, Byung-Duck;Seo, Joo-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.25-31
    • /
    • 2004
  • The heat transfer characteristics of a plasma display panel has been investigated for cooling an electronic module. Hence, a two dimensional $\kappa-{\varepsilon}$ turbulent model was developed to predict the temperatures of the panel and module. The heat conduction was solve for the material region. To consider the mixed convection at the solid-fluid interfaces between the air and the panel and module, the energy equation was solved simultaneously. When the electronic module stands face to face with the panel, the temperatures of panel and module are lower than other arrangement due to the chimney effect. However the gap between the panel and module does not affect significantly the maximum temperature when the aspect ratio is less than 0.1. To maintain the maximum temperature of the module under a certain limit, the passage of air should be well designed by the optimal layout of electronic modules which have different heat emission.

  • PDF

Numerical Analysis of Combined Natural and Forced Convection Around Cylinders (I) - Nusselt Numbers and Mixed convection Parameters - (실린더로 부터 전달되는 혼합대류 열전달의 수치해석 (I) -열전달계수-)

  • Moon, S.H.;Shih, T.M.;Johnson, A.T.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.37-51
    • /
    • 1986
  • 실린더로 부터 Prandtl수가 0.7인 주변공기로 전달되는 혼합대류 열전달현상이 Stream-Vorticitv 함수로 표시된 지배방정식으로 부터 유한차분법에 의해 분석되어졌다. Reynolds수와 Grashof수의 함수로서 혼합대류 열전달에서 Nusselt수의 값들이 조사되어 졌으며 이들로부터 순수자연대류와 혼합대류, 혼합대류와 순수강제대류사이의 범위를 정하였다. 그 외에도 본 연구에서는 실린더주변의 온도분포와, 공기속도분포, 속도분리점(Separation point), 마찰계수, 압력분포등이 조사되어졌으나 제 1편에서는 Nusselt수와 온도분포만이 연구결과로 주어 졌으며, 본시험의 이론적 결과치들은 발표된 실험치들과 잘 일치하였다.

  • PDF

Radative Effect on the Conjugate Mixed Convection-Conduction Heat Transfer along a Vertical Circular Cylindrical Fin (연직 원통윈에서의 혼합대류-전도 복합열전달에 미치는 복사효과)

  • 최상경;여문수;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1706-1716
    • /
    • 1991
  • 본 연구에서는 혼합대류하는 연직원통휜 열전달에 미치는 복사효과에 Rossel- and 근사해법을 도입한 층류 경계층방정식과 휜 전도방정식을 동시에 해석하여 복사 -전도매개변수(radiation-conduction parameter) M, 대류-전도 매개변수(convectionc- onduction parameter) N$_{c}$, 부력매개변수(buoyancy force parameter) R$_{i}$ 그 리고 횡곡률 매개변수(transverse curvature parameter) .lambda.를 계산 파라미터로 하여 휜 최적설계의 기본이 되는 총열전단률, 무차원 국소등가열전달계수, 무차원 국소열플 럭스 및 휜온도분포를 계산할 수 있는 일반성있는 algorithm을 개발하고 휜 성능에 관 한 결과들을 제공함으로써, 좀 더 완전한 복사 열플럭스를 도입한, 다음 연구를 위한 범용의 기초자료를 얻는데 본 연구의 목적이 있다.

A Experimental Study on Chracteristics of a Mixed Convection Heat Transfer in a Cavity with upper Channel (상부채널을 갖는 캐비티의 혼합대류 열전달에 관한 실험적연구)

  • Bae, Suk-Tae
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.115-121
    • /
    • 1998
  • In this study a channel cavity flow was performed. The channel has small size in the upper cavity region. At the gap is supplied by driven flow for Reynolds number. The experimental study was carried out in a channel cavity with square heat surface by visualization equipment with Mach-Zehnder interferometer and laser apparatus. Heat source was uniform heat flux($0.4W/cm^2,\;0.8W/cm^2,\;1.2W/cm^2$). When the bottom wall is heated, the tendency of natural convection flows are vigorous increasing heat flux.

  • PDF

Numerical Study on the Cooling of Induction Motor In a Washing Machine (세탁기용 유도모터의 냉각에 관한 수치적 연구)

  • Hong, Sang-Wook;Jeon, Si-Moon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.266-271
    • /
    • 2003
  • The numerical study was carried out to effectively cool Induction motor applied to a washing machine. The outer rotor made of steel periodically spins up and down. The stator consists of the thin layered iron plates and copper coil. The effective cooling system is necessary to solve the reliability problem caused by the electric losses at the coil and the iron plate. Because the heat transfer rate of the natural convection in partially open space is generally low, thus it is necessary to enhance the heat transfer using rotating perforated plate. The flow phenomena around the motor are very complex due to the motor geometry and the outer rotor motion. The mixed convection takes place due to the slow rotation speed. The three dimensional flow simulation was performed using rotating reference frame technique and Boussinesq approximation but the radiation effect was neglected. It was found that the angle and direction of the cooling blades play an important role in the stator temperature.

  • PDF

Upwind Finite Element Model for Suspended Sediment Transport

  • Noh, Joon-Woo
    • Journal of Wetlands Research
    • /
    • v.5 no.1
    • /
    • pp.67-78
    • /
    • 2003
  • The unsteady 2D convection and diffusion equation is solved numerically for the real-time simulation of suspended load propagation. The streamlined upwind scheme efficiently reduces numerical oscillations due to the high Peclet number in the convection dominant flow. By using the mixed boundary condition to express the external source terms or externally induced suspended load as a function of time in the algorithm, the model is capable of handling not only continuous load cases but also non-continuous suspended load influx. The suspended load transport modelwas verified using a case study for which an analytical exact solution is available and was applied to the real-time simulation of a suspended load influx case on the Mississippi River. The model algorithm can provide a framework upon which water quality as well as contaminant transport models can be built.

  • PDF

HYBRID DIFFERENCE SCHEMES FOR SINGULARLY PERTURBED PROBLEM OF MIXED TYPE WITH DISCONTINUOUS SOURCE TERM

  • Priyadharshini, R. Mythili;Ramanujam, N.;Valanarasu, T.
    • Journal of applied mathematics & informatics
    • /
    • v.28 no.5_6
    • /
    • pp.1035-1054
    • /
    • 2010
  • We consider a mixed type singularly perturbed one dimensional elliptic problem with discontinuous source term. The domain under consideration is partitioned into two subdomains. A convection-diffusion and a reaction-diffusion type equations are posed on the first and second subdomains respectively. Two hybrid difference schemes on Shishkin mesh are constructed and we prove that the schemes are almost second order convergence in the maximum norm independent of the diffusion parameter. Error bounds for the numerical solution and its numerical derivative are established. Numerical results are presented which support the theoretical results.

Analysis of Standard and FLIP Fuel Mixed Loading Patterns in TRIGA Mark-III Reactor

  • Kim, Jung-Do;Lee, Jong-Tai;Yook, Chong-Chul
    • Nuclear Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.287-293
    • /
    • 1979
  • Mixed standard-FLIP fuel loading patterns in the TRIGA Mark-III reactor were analyzed. It was judged that the mixed loading pattern with the standard fuel in the B-ring and the FLIP fuel in other rings was mostly desirable in view of fuel temperature, cooling condition with the natural convection, or effective thermal flux utilization in the central thimble. In addition, tile maximum useful flux in tile reactor beamports versus the loading patterns was evaluated.

  • PDF

Laboratory Experimentals and Numerical Analysis for Development of a Atmospheric Mixed Layer (대기 혼합층 발달 과정의 모형 실험과 수치 해석)

  • 이화운
    • Journal of Environmental Science International
    • /
    • v.2 no.1
    • /
    • pp.17-26
    • /
    • 1993
  • The layer that is directly influenced by ground surface is called the atmospheric boutsdary layer in comparison with the free atmosphere of higher layer. In the boundary layer, the changes of wind, temperature and coefficient of turbulent diffusion in altitude are large and have great influences an atmospheric diffusion. The purpose of this paper is to express the structure and characteristics of development of mixed layer by using laboratory experiment and numerical simulation. Laboratory experiment using water tank are performed that closely simulate the process of break up of nocturnal surface inversion above heated surface and its phenomena are analyzed by the use of horizontally averaged temperature which is observed. The result obtained from the laboratory experiment is compared with theoretical ones from ; \textsc{k}-\varepsilon numerical model. The results are summarized as follows. 1) The horizontally averaged temperature was found to vary smoothly with height and the mixed layer developed obviously being affected by the convection. 2) The mean height of mixed layer may be predicted as a function of time, knowing the mean initial temperature gradient. The experimental values are associated well with the theoretical values computed for value of the universal constant $C_r$= 0.16, our $C_r$ value is little smaller than the value found by Townsend and Deardoru et al.