• Title/Summary/Keyword: Mitigation phase

Search Result 115, Processing Time 0.026 seconds

A Study on Police Officers' Awareness Of Counter-Terrorism - Focused on the Comprehensive Emergency Management Model - (경찰공무원의 대테러리즘 인식에 관한 연구 - Comprehensive Emergency Management Model을 중심으로-)

  • Joo, Seong Bhin
    • Convergence Security Journal
    • /
    • v.17 no.3
    • /
    • pp.103-114
    • /
    • 2017
  • Terrorism is a serious problem in that it can infringe on a broad range of legal interests, from individual legal interests to national legal interests. And if these legal values are damaged, it is very unlikely that they will be restored to their original state. Therefore, it is necessary to recognize the importance of preventive activities as well as institutional improvement and alternative policies. The role of the criminal justice authority is of paramount importance in ensuring proactive action and procedural legitimacy. It would be meaningful to look at their perception about terrorism before specific procedures and legal approaches are taken. A Study is related terrorism awareness of police officers - focused on 'Comprehensive Emergency Management Model'. Four phases of Comprehensive Emergency Management Model: mitigation, preparedness, response, and recovery.

Vulnerability Analysis and Threat Mitigation for Secure Web Application Development (안전한 웹 애플리케이션 개발을 위한 취약점 분석 및 위협 완화)

  • Moon, Jae-Chan;Cho, Seong-Je
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.2
    • /
    • pp.127-137
    • /
    • 2012
  • Recently, as modern Internet uses mashups, Web 3.0, JavaScript/AJAX widely, the rate at which new vulnerabilities are being discovered is increasing rapidly. It can subsequently introduce big security threats. In order to efficiently mitigate these web application vulnerabilities and security threats, it is needed to rank vulnerabilities based on severity and consider the severe vulnerabilities during a specific phase of software development lifecycle (SDLC) for web applications. In this paper, we have first verified whether the risk rating methodology of OWASP Top 10 vulnerabilities is a reasonable one or not by analyzing the vulnerability data of web applications in the US National Vulnerability Database (NVD). Then, by inspecting the vulnerability information of web applications based on OWASP Top-10 2010 list and CWE (Common Weakness Enumeration) directory, we have mapped the web-related entries of CWE onto the entries of OWASP Top-10 2010 and prioritized them. We have also presented which phase of SDLC is associated with each vulnerability entry. Using this approach, we can prevent or mitigate web application vulnerabilities and security threats efficiently.

Mitigation of Inter-Symbol Interference in Underwater Acoustic Communication Using Spatial Filter (공간 필터를 이용한 수중음향통신의 인접 심볼 간 간섭 완화)

  • Eom, Min-Jeong;Park, Ji-Sung;Ji, Yoon-Hee;Kim, J.S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.48-53
    • /
    • 2014
  • The underwater acoustic communication (UAC) is characterized by doubly spread channel. It is included in the time-variant doppler shift and delay-time spreads due to multiple paths. To compensate such distorted signals, various techniques including time-reversal processing, spatial diversity, phase estimator, and equalizer are being applied. In this paper, a spatial filter based on the beamforming is proposed as a method to mitigate such inter-symbol interferences that are generated in time-varying multipath channels. The proposed technique realizes coherent communications by steering the direction of the desired signals and improves the performance of UAC by increasing the signal-to-interference plus noise ratio using the array gain.

Harmonic Mitigation and Power Factor Improvement using Fuzzy Logic and Neural Network Controlled Active Power Filter

  • Kumar, V.Suresh;Kavitha, D.;Kalaiselvi, K.;Kannan, P. S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.520-527
    • /
    • 2008
  • This work focuses on the evaluation of active power filter which is controlled by fuzzy logic and neural network based controller for harmonic mitigation and power factor enhancement. The APF consists of a variable DC voltage source and a DC/AC inverter. The task of an APF is to make the line current waveform as close as possible to a sinusoid in phase with the line voltage by injecting the compensation current. The compensation current is estimated using adaptive neural network. Using the estimated current, the proposed APF is controlled using neural network and fuzzy logic. Computer simulations of the proposed APF are performed using MATLAB. The results show that the proposed techniques for the evaluation of APF can reduce the total harmonic distortion less than 3% and improve the power factor of the system to almost unity.

QoS Priority Based Femtocell User Power Control for Interference Mitigation in 3GPP LTE-A HetNet

  • Ahmad, Ishtiaq;Kaleem, Zeeshan;Chang, KyungHi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.2
    • /
    • pp.61-74
    • /
    • 2014
  • In recent years, development of femtocells are receiving considerable attention towards increasing the network coverage, capacity, and improvement in the quality of service for users. In 3GPP LTE-Advanced (LTE-A) system, to efficiently utilize the bandwidth, femtocell and macro cell uses the same frequency band, but this deployment poses a technical challenge of cross-tier interference to macro users. In this paper, the novel quality of service based fractional power control (QoS-FPC) scheme under the heterogeneous networks environment is proposed, which considers the users priority and QoS-requirements during the power allocation. The proposed QoS-FPC scheme has two focal points: firs, it protects the macrocell users uplink communication by limiting the cross-tier interference at eNB below a given threshold, and second, it ensures the optimization of femtocell users power allocation at each power adjustment phase. Performance gain is demonstrated with extensive system-level simulations to show that the proposed QoS-FPC scheme significantly decreases the cross-tier intereference and improves the overall users throughput.

Runoff Estimation Considering Dividing Watershed (유역 분할을 고려한 유출량 산정)

  • Lee, Jong-Hyeong;Yoon, Seok-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.1 s.24
    • /
    • pp.57-66
    • /
    • 2007
  • The purpose of this study is both the variation of hydrologic topographical informations extracted by using WMS and the quantitative effect of rainfalll-runoff simulation due to dividing watershed. Miho stream basin in Geum river was selected by this study. Watershed dividing method are determined by area, channel slope and channel length. Hydrological response of divided watershed using Clark method, SCS method and Snyder method was compared with actual measured flood hydrograph. As a results, area-based watershed dividing method are particularly suitable the hydrologic applications using SCS method. This study can be used as basic data for the phase of the runoff variation in Miho stream basin.

Simulation of Contaminant Draining Strategy with User Participation in Water Distribution Networks

  • Marlim, Malvin S.;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.146-146
    • /
    • 2021
  • A contamination event occurring in water distribution networks (WDNs) needs to be handled with the appropriate mitigation strategy to protect public health safety and ensure water supply service continuation. Typically the mitigation phase consists of contaminant sensing, public warning, network inspection, and recovery. After the contaminant source has been detected and treated, contaminants still exist in the network, and the contaminated water should be flushed out. The recovery period is critical to remove any lingering contaminant in a rapid and non-detrimental manner. The contaminant flushing can be done in several ways. Conventionally, the opening of hydrants is applied to drain the contaminant out of the system. Relying on advanced information and communication technology (ICT) on WDN management, warning and information can be distributed fast through electronic media. Water utilities can inform their customers to participate in the contaminant flushing by opening and closing their house faucets to drain the contaminated water. The household draining strategy consists of determining sectors and timeslots of the WDN users based on hydraulic simulation. The number of sectors should be controlled to maintain sufficient pressure for faucet draining. The draining timeslot is determined through hydraulic simulation to identify the draining time required for each sector. The effectiveness of the strategy is evaluated using three measurements, such as Wasted Water (WW), Flushing Duration (FD), and Pipe Erosion (PE). The optimal draining strategy (i.e., group and timeslot allocation) in the WDN can be determined by minimizing the measures.

  • PDF

Induction Motor Drives with Low Switching Acoustic Noise Based on the Two-Phase Modulated Random Lead-Lag PWM Scheme (2상 변조된 랜덤 Lead-Lag PWM기반의 저 스위칭 소음 유도모터 구동 시스템)

  • 위석오;정영국;임영철;양승학
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.151-164
    • /
    • 2003
  • In this paper, induction motor drives with low switching acoustic noise based on the 2 phase modulated RLL(Random Lead-Lag) PWM is proposed and implemented. The proposed switching method is much bettor than 3 phase modulated RLL-PWM from the standpoint of the broadening effect of the acoustic noise spectrum. Along with the randomization of PWM Pulses, SVM(Space Vector Modulation) is executed in the TMS320C31 DSP(Digital Signal Processor). To verify the validity of the proposed RPWM(Random PWM), the experimental study was tried. The experimental results show that the performance of the proposed method and the 3 phase center-aligned SVM / conventional RLL-PWM are nearly the same from the viewpoint of the constant v/f centrel. But, in case of the proposed 2 phase modulated RLL-PWM, the spectrum characteristics of the voltage and the switching acoustic noise are shown to have better broadening effect than 3 phase modulated one.

OVERVIEW OF COMS GROUND SYSTEM AT METEOROLOGICAL SATELLITE CENTER OF KMA

  • Lee, Hyun-Kyoung;Lee, Bong-Ju;Lee, Yong-Sang;Shim, Jae-Myun;Suh, Ae-Sook;Kim, Hong-Sic;Je, Chang-Eon
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.159-162
    • /
    • 2006
  • This paper describes the ground system for COMS (Communication, Ocean, and Meteorological Satellite), the first Korean multi-purposed geostationary satellite, at MSC (Meteorological Satellite Center) in Korea. The overview of COMS MI (Meteorological Imager) will be introduced as well. KMA would implement mission planning for COMS MI operation and receive, process, interpret, disseminate, and archive MI data operationally for domestic and foreign user groups. Major missions of COMS MI are mitigation of natural hazard such as typhoon, dust storm, and heavy rain, and short-term warning of severe weather to protect human health and commerce. Moreover, research of climate variability and long-term changes will be supported. In accordance with those missions, the concept and design of COMPASS (COMS operation and meteorological products application service system), the ground system for COMS MI in MSC, have been setting up since 2004. Currently, COMPASS design is being progressed and will have finished the end of 2006. The development of COMPASS has three phases: first phase is development of fundamental COMPASS components in 2007, second phase is to integrate and test all of the COMPASS components in 2008, and the last phase is to operate COMPASS after COMS In-Orbit Tests in 2009.

  • PDF

1-D Two-phase Flow Investigation for External Reactor Vessel Cooling (원자로 용기 외벽냉각을 위한 1차원 이상유동 실험 및 해석)

  • Kim, Jae-Cheol;Park, Rae-Joon;Cho, Young-Rho;Kim, Sang-Baik;Kim, Sin;Ha, Kwang-Soon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.5
    • /
    • pp.482-490
    • /
    • 2007
  • When a molten corium is relocated in a lower head of a reactor vessel, the ERVC (External Reactor Vessel Cooling) system is actuated as coolant is supplied into a reactor cavity to remove a decay heat from the molten corium during a severe accident. To achieve this severe accident mitigation strategy, the two-phase natural circulation flow in the annular gap between the external reactor vessel and the insulation should be formed sufficiently by designing the coolant inlet/outlet area and gap size adequately on the insulation device. For this reason, one-dimensional natural circulation flow tests and the simple analysis were conducted to estimate the natural circulation flow under the ERVC condition of APR1400. The experimental facility is one-dimensional and scaled down as the half height and 1/238 channel area of the APR1400 reactor vessel. The calculated circulation flow rate was similar to experimental ones within about ${\pm}$15% error bounds and depended on the form loss due to the inlet/outlet area.