• Title/Summary/Keyword: Mist Cooling

Search Result 84, Processing Time 0.021 seconds

A study on the Water Mist Fire Suppression Performance (미세 물 분무 소화 성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.61-65
    • /
    • 2002
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility. The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was concluded to be cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

  • PDF

A Study on the Fire Suppression Characteristics Using a Water Mist (물분무에 의한 화재제어 특성에 관한 연구)

  • 김성찬;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The present study investigates the fire suppression characteristics using a water mist fire suppression system. Numerical simulations of fire suppression with water mist are performed with considering the interaction of fire plume and water droplet, droplet evaporation, and combustion of pool fire. The predicted temperature fields of smoke layer are compared with that of measured data. Numerical results agree with the experimental results within 5$^{\circ}C$ in the case without water mist In the case of fire suppression with water mist, numerical results dose not predict well lot temperature field in the gradual cooling region after water mist injection. But the predicted results of initial fire suppression are in good agreement with that of measured data. The reason of the discrepancy between predicted and measured data is due to the variation of turning rate during the injection of water mist. The effect of burning rate on the fire suppression is left as future study.

A Study on the Performance of Water Mist Spray Fire Protection System (미세물분무 소화성능에 관한 연구)

  • 김봉환;김용판;문철진;홍철현;이형욱;최현호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.572-578
    • /
    • 2003
  • The present study was numerically and experimentally performed to investigate the fire suppression performance of water mist spray subjected to thermal radiation in closed space. Downward-directed water mist sprays to interact with an under kerosine pool fire were investigated in test facility The mass mean diameters of water mist droplet were measured by PMAS under various flow conditions. The developed water mist spray nozzle was satisfied to the criteria of NFPA 750, Class 1. The mechanism of the fire suppression by water mist was attributed to the cooling of the fire surface which lead to suppressed of fuel evaporation. It was proved that the water mist spray system under lower pressures could be applied to underground fire protection system.

Analysis of Misting Phenomenon in a Car (자동차 내부의 김 서림 현상에 관한 연구)

  • Kwak, Min-Kyoung;Kim, Jae-Hwan
    • Atmosphere
    • /
    • v.17 no.1
    • /
    • pp.109-114
    • /
    • 2007
  • The mist on the inside of an automobile windshield is not only uncomfortable but also very dangerous because it obstructs the driver's vision. However, the removal process of the mist has never been studied in detail. This study performed experiments analyzing the mechanism causes the mist in a car and investigated the appropriate removal process. The experiments were performed on two rainy days, 10 April 2006 and 26 May 2006, with temperature and relative humidity sensors of testo-175-H2 and DICKSON-TK500. We found a passenger increased water vapor by 0.2 g $min^{-1}$ through respiration and thereby relative humidity (RH) from 55% to 67% in 8 minutes. Even though RH was not saturated, misting occurred because the humid air contacted the colder surface of the window. To remove the mist, it is necessary to increase the temperature or inflow drier air in the car. Therefore, we expected that the heater would be more effective than air conditioner for this matter. However, the outcome was the other way around due to the structure of the heating and cooling system in the car. When the air-conditioner was on, colder and drier air was generated and flowed through the so-called evaporator. Droplets were produced in the evaporator due to cooling procedure. When the heater was on, the warm air evaporated the droplets and increased the water content in the air resulting in an increase of relative humidity. Consequently, the air conditioner is more effective than the heater to remove the mist.

Spray Flow Characteristics of Twin-fluid Water Mist Nozzle for Fire Suppression (2유체 미세 물분무 소화노즐의 분무유동 특성)

  • Kim, Bong-Hwan;Choi, Hyo-Sung;Kim, Dong-Keon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.60-66
    • /
    • 2011
  • In the present investigation, experimental studies were conducted on the fire suppression performance of twin-fluid water mist spray which is subjected to thermal radiation in a closed space. Downward-directed water-mist sprays, interacting with an under kerosene pool fire, were investigated in a test facility. The mass mean diameter of water-mist droplets were measured by PMAS under various flow conditions. The developed twin-fluid water mit spray nozzle satisfied the criteria of NFPA 750, Class 1. The mechanism of fire suppression by fine water mist was concluded to be the cooling of the fire surface which leads to the suppression of fuel evaporation. It was proved that the automatic twin-fluid water mist spray system under lower pressures could be applied to an industrial facilities.

Analysis for fire suppression efficiency of intermittent water spray pattern with FDS (FDS를 이용한 교번식 미분무방식의 소화 성능 분석)

  • Jee, Moon-Hak;Lee, Byung-Kon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.200-203
    • /
    • 2008
  • Water mist fire suppression system utilizes the fire suppression features such as cooling of fire source, dilution of ambient oxygen, and shielding of radiation heat with the evaporation of microscopic water droplets. The momentum of water mist is relatively low and the infiltration of water mist to the fire source is not effective. In addition to lower penetration force, the evaporated water vapor is liable to decline to limited portion of fire source due to its light weight and sparse density. On the other hand, the cycling water mist system is expected to improve the penetration force of water mist as well as the dilution coverage capability with the stratified spray characteristics. At this paper we present the analyzed fire suppression capability of intermittent water spray pattern by use of FDS which is computational fire dynamics fire model. We expect this analysis shall be supportive to the development of the prototype of water mist nozzle.

  • PDF

Fire Suppression Effect of PPV with Water Mist System (미세물분무를 이용한 PPV의 화재진압효과)

  • Kim, Sung-Won;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.71-77
    • /
    • 2003
  • To inject fresh air into a fire room, Positive Pressure Ventilation (PPV) can be used and the blower of PPV increases inside pressure of the room. It makes high flow rate of products of combustion, smoke and heat from the structure, and it is very helpful to fireman on the fire extinguishing work. The flame moves to the direction of airflow and the temperature of flame can be decreased rapidly. In this experiment, a water mist system is applied to PPV to increase the effectiveness, and various effective factors are studied. n-Heptane and pine wood stick were used as fuel. Temperatures at the above and behind the combustion pan were strongly reduced by the water mist system and by the convective cooling with airflow. The smoke density was also decreased by PPV with water mist system and it can be explained by the absorption of smoke particles on the water mist droplet and by the strong exhausting effects of mobile fan.

A Study on the Grinding Characteristics According to Cooling Methods (대체냉각 기술을 이용한 환경친화 연삭가공 기술)

  • Lee, S.W.;Choi, H.Z.;Heo, N.H.;Lee, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.962-967
    • /
    • 2003
  • Recently, environmental pollution has become a serious problem in industry, and many researches have been done in order to preserve the environment. The coolant, which promotes lubrication, cooling and penetration, contains chlorine, sulfur and phosphorus to improve the machining efficiency. These additives, which move around into the air during machining, pollute working. Therefore, many researches on how to reduce the amount of coolant during machining have been carried out. However, to reduce even small amount of coolant causes high temperature of a workpiece and it brings thermal defects. In this study, the experiments of wet & dry grinding using cooling methods (using coolant only, mist and compressed cold air only) are performed to solve the problem of environmental contamination and to get a better surface integrity of a workpiece by comparing surface roughness, roundness and residual stress.

  • PDF

Effect of Cooling Method on Surface Roughness in Turning (선삭가공에서 표면 거칠기에 미치는 냉각방법의 영향)

  • Kim, Yeong-Duck
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.87-93
    • /
    • 2011
  • CNC lathe machining has been widely used for parts machining of vehicles, aircraft, ships, electronics, etc. because cost savings for shortening processing time and increasing productivity are great. In this study, the purpose is to investigate the effect of cooling methods such as oil mist, water-soluble cutting oils on the workpiece surface roughness with the cutting speed, cutting depth, tool nose radius and feed rate of CNC lathe machine as a parameter in the cutting process of the aluminum alloy 2024 which is used a lot recently on aircraft parts. It is found that oil mist is coolant and water-soluble cooled by cutting the experimental conditions, cutting speed and cutting depth without effecting the surface roughness value was constant.

Application of Water Mist System for a Power Transformer Room -Cooling Characteristics (Part 2) (변압기실 화재에 대한 미분무수 소화시스템의 적용 -냉각특성을 중심으로(Part 2))

  • Choi Byung-Il;Han Yong-Shik;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.37-41
    • /
    • 2005
  • The present study describes the cooling performance of two kinds of water mist systems used in fire extinguishment. The cooling is necessary for the prevention of an auto re-ignition of the power transformer. A heat source for such the re-ignition is the accumulated thermal energy in the dielectric oil from the transformer core. Because of the weight of the real core, reduced-scale experiments are carried out. A similarity analysis Is also performed to determine the discharge time of the water mist systems from the experimental results. The discharge time to prevent the re-ignition in the real-scale transformer is estimated about 12 hour from the similarity analysis of the reduced-scale experiments.