• Title/Summary/Keyword: Minimum standards

Search Result 473, Processing Time 0.032 seconds

Improvement for Classification System of Building Use on Neighborhood Living Facility (근린생활시설 용도분류체계 개선방안 연구)

  • Lee, Sung-Ok;Hwang, Eun-Kyoung
    • Journal of architectural history
    • /
    • v.21 no.6
    • /
    • pp.53-62
    • /
    • 2012
  • The purpose of this study is to present improvement for classification system of current neighborhood living facility to correspond rapid social change and various industries after understanding its status and problem. In current Building Standard Law, various kinds of buildings are classified for their structure, purpose of use, and building types. The Neighborhood Living Facility is divided into First Neighborhood Living Facility and Second Neighborhood Living Facility with applying area standards, according to facilities of convenience degree for neighborhood inhabitants. This classification, however, has problem in an arbitrary decision and applying of buildings without any definition or standards to adopt. And, there are some mixed neighborhood public functional facilities and amusement business affecting public morals among the Neighborhood Living Facility, so hazard environmental problems are also existed. According to the improved program, the study presents a prompt adoption of new facilities according to various industry increase, with minimum public discontent over adopted area standards. This study suggests making a clear scope through reclassification of Neighborhood Living Facility within the scope of the law on current Neighborhood Living Facility and an improvement plan of introducing necessary definitions on purpose of facility.

A Study on Improvement of Inflow/Infiltration Computation and Application Method in Sewer Rehabilitation Project (하수관거정비사업의 침입수/유입수 산정 및 활용방법 개선방안에 관한 연구)

  • Kim, Jong-Oh;Jeong, Dong-Gi;An, Dae-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.1
    • /
    • pp.33-45
    • /
    • 2014
  • In this study, current sewer infiltration/Inflow(I/I) computation and application method was examined about improvement and adequacy relating to the main issues raised by the field for practitioners. The results of review about infiltration calculation method were considered to be in need of improvement at 'standards of minimum sewage calculation'. Furthermore, the results of review about I/I application method were considered to be in need of improvement at 'standards of seasonal infiltration application' and 'the relative decrease in the Annual evaluation standards'. In addition, annual I/I analysis at JC County for the four years(2009~2012) in respect of operation flow and rainfall data was conducted. The result of annual infiltration analysis, compared average daily sewage generated average infiltration rate was found in 21.95 %, infiltration by unit was found in $0.31m^3/day/cm/km$ and $0.12m^3/day/day$, respectively. The result of annual inflow analysis, average rainfall - Inflow equations was found $y=5.499{\times}$($R^2$ 0.793), and the average Inflow quantity by sewer extension was predicted to $0.66m^3/mm-km$.

A study on Design Guideline on the disabled children nurturing facilities in Japan (일본 장애아 보육시설의 법적 기준 및 문헌에 관한 연구)

  • Lee, Ji-Ye;Ju, Seo-Ryeung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.410-420
    • /
    • 2008
  • The progress of industrialization in Korea has led to increase social participation by females and also a transition toward a nuclear family based system. As a result of it, Korea is nowadays confronted with the issue of childcare, which is emerging as a social problem. In Japan, both combined nurturing facilities and the exclusively dedicated facilities for disabled children are institutionally maintained on a consistent basis. In addition, the enactment of the Children Welfare Act has subsequently given birth to the establishment of the 'Minimum Standard Requirements for Children's Welfare Facilities'. With such act and standards in place, much attention is now paid to a physical improvement of disabled children nurturing facilities, too. In order to make the requirements for such facilities more complete and substantial, local governments have enacted their own ordinances on the basis of the major policies regarding the universal designs for the disabled, such as the Heart Building Act. As Japan has a cultural background similar to that of Korea and is equipped with the nurturing facilities systemized in accordance with the symptom and degree of disabilities, it is believed that a study on the current standards for disabled children in Japan will help to provide our domestic standards applicable to such facilities.

  • PDF

Magnetization Behavior of Ultra-thin FexCo1-x Alloy on Cr (100) Surface

  • Hossain, M.B.;Kim, C.G.;Chun, B.S.;Kim, W.;Hwang, C.Y.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2013.05a
    • /
    • pp.15-16
    • /
    • 2013
  • Magnetization behavior of ultra thin $Fe_xCo_{1-x}$ alloy (where x varies from 0 to 100) has been investigated as functions of composition on Cr (100) substrate by using in situ surface magneto optical Kerr effect (SMOKE). It's always show in plane uniaxial magnetic anisotropy at room temperature (RT) & Low temperature (LT). It is observed that composition dependent coercive force maximum at about 30 at % Co and 70 at % Co atomic ratio and minimum near equiatomic site. The relative magnetic moments as composition variation also show magnetization collapse near equiatomic site. The magnetization behaviors of Fe-Co alloy on Cr (100) due to composition varies are supported the order-disordering as well as structural stability bcc (ferromagnetic)/fcc (anti-ferromagnetic) phase stability magnetism.

  • PDF

Defect Sizing and Location by Lock-in Photo-Infrared Thermography (위상잠금 광-적외선 열화상 기술을 이용한 내분결함의 위치 및 크기 평가)

  • Choi, Man-Yong;Kang, Ki-Soo;Park, Jeong-Hak;Kim, Won-Tae;Kim, Koung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.321-327
    • /
    • 2007
  • In lock-in thermography, a phase difference between the defect area and the healthy area indicates the qualitative location and size of the defect. To accurately estimate these parameters, the shearing-phase technique has been employed which gives the shearing-phase distribution. The shearing-phase distribution has maximum, minimum, and zero points that help determine quantitatively the size and location of the subsurface defect. In experiment, the proposed technique is verified with artificial specimen and these related factors are analyzed.

The Effect of Test Variables on the Accuracy of Equo-Tip Hardness (Equo-Tip 경도값에 미치는 실험변수의 영향)

  • Nahm, S.H.;Jeon, S.B.;Kim, J.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.3 no.2
    • /
    • pp.32-36
    • /
    • 1990
  • For the accurate measurements of hardness in a material, it is necessary to have a thorough understanding of the effects of test variables on the accuracy of hardness value. For the rebound hardness test, major test variables are the radius of hammer ball tip, type of backing materials, size and roughness of the specimen. In this study, effects of these variables on Equo-Tip hardness value were investigated. Hardness measurements were carried out using WC balls with various sizes of worn-ot zone. The sample materials chosen for the experiments were commercial standard hardness blocks and SM45C steel bars subjected to either normalization or quench and temper treatments. As backing materials, aluminum, steel and rubber plates were used in all the experiments. Experimental results show that for the accurate measurements of Equo-tip hardness, it is necessary to use the hammer ball with a worn-out zone parameter of less than 0.23, and the recommended minimum thickness and width of the specimen are 25mm and 70mm, respectively. Further for the surface preparation, the specimens need to be polished with an emery paper of No. 400 or finer, and for the backing matrials, it is recommended to use steels or rubbers.

  • PDF

QoS Based IrDA in Mobile Phones

  • Kim Jong Sung;Yoon Sang Sub;Chun Byung Sik
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.528-531
    • /
    • 2004
  • This paper presents the design and implementation of a QoS based IrDA in mobile phones. The IrDA standards have arised from the need to connect various mobile devices together. But currently, we have a difficult to connecting various mobile devices together. The difficult thing is to adjust the minimum turn around time. The minimum turn around time in IrDA deals with the time needed for a receiver circuit to recover following saturation by transmissions from the same device (turn around latency). This parameter corresponds to the required time delay between the last byte of the last frames sent by a station and the point at which it is ready the first byte of a frame from another station. This parameter comes into play when the link is turned around and is negotiated independency for each station. We solve this matter by using the Dynamic Adjustment Algorithm (DAA). The dynamic adjustment algorithm adjusts the minimum turn around time according to the numbers of devices. We apply our direct adjustment algorithm to our QoS based IrDA in mobile phones and show the improved performance of connection with various mobile phones together.

  • PDF

A Study on Estimation of Cooling Load Using Forecasted Weather Data (집단 건물 면적을 이용한 시간별 냉방부하 파라미터 설정 및 예측에 관한 연구)

  • Han, Kyu-Hyun;Yoo, Seong-Yeon;Lee, Je-Myo;Song, Yang-Sup
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.440-445
    • /
    • 2008
  • In this paper, new methodology is proposed to estimate the cooling load using areas of building group and predicted weather data. Only three parameters such as maximum, minimum temperature and building area are necessary to obtain hourly distribution of cooling load for the next day. The maximum and minimum temperature that are used for input parameters can be obtained from forecasted weather data. The areas of building group are used for setting several parameters that are used for estimate cooling loads. Benchmarking building(research building) is selected to validate the performance of the proposed method, and the estimated cooling loads in hourly bases are calculated and compared with the measured data for benchmarking building. The estimated results show fairly good agreement with the measured data for benchmarking building.

  • PDF

Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation (접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가)

  • Moon, Ki Hoon;Han, Sang Whan;Ha, Seung Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.

Expert opinions on improvement of current food code related to hygiene management standards for cooked foods in restaurants (현행 식품접객업소 조리식품 위생관리 기준 보완에 관한 전문가 의견)

  • Ju, Seyoung;Kawk, Hyoseon;Hong, Wansoo;Kwak, Tongkyung;Chang, Hyeja
    • Journal of Nutrition and Health
    • /
    • v.49 no.3
    • /
    • pp.201-212
    • /
    • 2016
  • Purpose: Needs for reevaluation of food code standards and regulations for cooked foods produced in restaurants and institutional foodservice to minimize risk factors leading to foodborne outbreaks are on the rise. The purpose of the study was to propose updated standards for cooked foods of restaurants by testing whether or not experts agree to include them as a standard. Methods: Qualitative and quantitative research methods were applied via a survey by email and workshop hold for experts panel discussions. Results: Seven newly proposed standards were selected as follows: (1) sanitizing vegetables and fruits with no heating process after washing, (2) rapid cooling of cooked foods after heating process, (3) monitoring cooking temperatures, (4) minimum 2 hours holding after cooking for temperature control of safety (TCS) foods without temperature control, (5) banning practices for workers such as bare hands handling of ready-to-eat foods, (6) maintaining cleanliness of food contact surfaces for disposable products, and (7) cold holding standards for sushi. Conclusion: The proposed proposal can be utilized as control measures for preventing foodborne illness in restaurants. However, a feasibility study should be conducted to test whether they are applicable to the field of restaurant operation.