• Title/Summary/Keyword: Minimum Zone Method

Search Result 128, Processing Time 0.029 seconds

Strain Analysis of Nd:YAG Laser Welding Zone by Speckle Interferometry (스페클 간섭법에 의한 Nd:YAG 레이저 용접부의 변형해석)

  • 김경석;김성식;정승택;김종수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.85-89
    • /
    • 2002
  • This paper used the Laser Speckle Interferometry to present the strain analysis of Nd:YAG Laser welding zone. Previous TIG welding to sheet plate, which welds only high-skilled engineer, produces residual stress nearby welding zone due to thermal effect. However, Laser welding makes sheet pate welding easy and thermal effect minimum. Thermal effect zone is measured by strain analysis of the laser-welding zone by ESPI under tensile testing of sheet plate welded by Nd:YAG laser. The ESPI results, which compared with strain gage method, are agreed within error 3 %.

  • PDF

A Study on the Classification Criteria of Climatic Zones in Korean Building Code Based on Heating Degree-Days (난방도일 기반 대한민국 행정구역별 기후존 구분 기준 정립에 관한 연구)

  • Noh, Byeong Il;Choi, Jaewan;Seo, Donghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.11
    • /
    • pp.574-580
    • /
    • 2015
  • Climatic zone in building code is an administrative district classification reflecting regional climatic characteristics. Use of Degree-Days is a fundamental method that can be used in various building design codes, analysis of building energy performance, and establishment of minimum thermal transmittance of building envelopes. Many foreign countries, such as the USA, the EU, Australia, Italy, India, China, etc., have already adapted climatic zone classification with degree-days, precipitation or amount of water vapor based on the characteristics of their own country's climate. In Korea, however, the minimum requirements for regional thermal transmittance are classified separately for the Jungbu area, Nambu area and Jeju Island with no definite criterion. In this study, degree-days of 255 Korean cities were used for climatic zone classification. Outdoor dry-bulb temperature data from the Korea Meteorological Administration for 1981~2010 was used to calculate degree-days. ArcGIS and the calculated degree-days were utilized to analyze and visualize climatic zone classification. As a result, depending on the distribution and distinctive differences in degree-days, four climatic zones were derived : 1) Central area, 2) Mountain area of Gyeonggi and Gangwon provinces, 3) Southern area, and 4) Jeju Island. The climatic zones were suggested per administrative district for easy public understanding and utilization.

Numerical Computation of Bearing Capacity Factor $N_{\gamma}$ (지지력 계수 $N_{\gamma}$의 수치적 산정법)

  • Kim, Won-Cheul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.565-573
    • /
    • 2004
  • This study is to present explicit analytical expressions for calculating bearing capacity factor $N_{\gamma}$, to provide results of the numerical computation instead of the graphical method. In this study, $N_{\gamma}$ is proposed in the critical failure surface on assumption that the center of log spiral in the radial shear zone can be located at the any points of around footing. The critical failure surface is one which yields minimum passive pressure $P_{\gamma}$ on the radial shear zone from the family of log spirals accoding to change of the center of log spiral. This study adoptes Terzaghi's bearing capacity principle(e.g., Prandtl's mechanism, limit equilibrium equation, superposition principle) but the soil wedge in an elastic zone makes angle $45^{\circ}+{\phi}/2$ with the horizontal and the location of the log spiral's center.

  • PDF

Mixing Zone Analysis of Wastewater Effluent Discharged from Sokcho Ocean Outfall (속초 해양방류 하.폐수의 혼합구역에 대한 특성분석)

  • 강시환;박연숙;김상익;이호진
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.3
    • /
    • pp.245-253
    • /
    • 2001
  • Mixing zone characteristics of the wastewater effluents discharged from Sokcho ocean outfall have been investigated using an outfall mixing zone model which was developed on the basis of Huang et al.'s(1996) analysis method. The model was applied to Sokcho ocean outfall case and was used to simulate the concentration distribution of wastewater effluents using winter season's data, ie. daily effluent flowrate, ocean current and density stratification data which were measure for two months in the outfall area. Hourly concentration distribution of outfall effluent discharges was calculated and they were averaged for the period of 15 days which covers the ambient flow variability of the neap and the spring tidal currents. The results show that near-field dilution was relatively high with the minimum dilution of 130 for the winter season. The mixing zone was extended to the coastal beach area rather than offshore because of major direction of coastal currents. This may cause a deteriorating impact on coastal water quality, especially to the adjacent swimming beach area.

  • PDF

Effect of interference and Ground Movement by Twin Tunnelling (쌍굴터널 굴진에 따른 주변지반의 거동과 간섭효과)

  • 김학문
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.136-142
    • /
    • 1997
  • The behaviour of ground movement during the construction of two parallel tunnels in weathered zone and soft rock has been investigated. All the influencing factors for the behaviour of twin tunnel such as tunnel size, ground conditions, tunnel depth, pillar width and initial state of ground stresses were examined The results of FEM nonlinear analysis were compared with some of model test results in weathered zone to verify the numerical method. It was found that minimum interference was obtained in the parallel construction case when the twin tunnel distance (pillar width) is just over the twice of tunnel diameter. Guide line for the interference of twin tunnelling has been introduced for the ground of weathered zone and soft rock.

  • PDF

Urban Growth of Chuncheon City Observed by Landsat Satellite Images

  • Ahn, Young-Jin;Lee, Hoon-Yol
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.411-414
    • /
    • 2005
  • In this study, 8 Landsat(TM/ETM+) satellite images acquired from 1984 to 2002 were used to investigate the growth of Chuncheon city, Kangwon-do, Korea. The images were geocoded and classified using training set collected from field survey. Four land-use types were classified such as urban area, green zone, agricultural land and water body. It also showed rapid increase of urban area in the past two decades from 1166ha in 1984 to 3358ha in 2002. About 2182ha of agricultural land and green zone have been changed to urban area. Agricultural land was newly formed from the green zone.

  • PDF

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Analysis of Rainfall Runoff Delay Effect of Vegetation Unit-type LID System through Rainfall Simulator-based Probable Rainfall Recreation (인공강우기 기반 확률강우재현을 통한 식생유니트형 LID시스템의 우수유출지연 효과분석)

  • Kim, Tae-Han;Park, Jeong-Hyun;Choi, Boo-Hun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.22 no.6
    • /
    • pp.115-124
    • /
    • 2019
  • In a climate change environment where heat damage and drought occur during a rainy season such as in 2018, a vegetation-based LID system that enables disaster prevention as well as environment improvement is suggested in lieu of an installation-type LID system that is limited to the prevention of floods. However, the quantification of its performance as against construction cost is limited. This study aims to present an experiment environment and evaluation method on quantitative performance, which is required in order to disseminate the vegetation-based LID system. To this end, a 3rd quartile huff time distribution mass curve was generated for 20-year frequency, 60-minute probable rainfall of 68mm/hr in Cheonan, and effluent was analyzed by recreating artificial rainfall. In order to assess the reliability of the rainfall event simulator, 10 repeat tests were conducted at one-minute intervals for 20 minutes with minimum rainfall intensity of 22.29mm/hr and the maximum rainfall intensity of 140.69mm/hr from the calculated probable rainfall. Effective rainfall as against influent flow was 21.83mm/hr (sd=0.17~1.36, n=20) on average at the minimum rainfall intensity and 142.27mm/hr (sd=1.02~3.25, n=20) on average at the maximum rainfall intensity. In artificial rainfall recreation experiments repeated for three times, the most frequent quartile was found to be the third quartile, which is around 40 minutes after beginning the experiment. The peak flow was observed 70 minutes after beginning the experiment in the experiment zone and after 50 minutes in the control zone. While the control zone recorded the maximum runoff intensity of 2.26mm/min(sd=0.25) 50 minutes after beginning the experiment, the experiment zone recorded the maximum runoff intensity of 0.77mm/min (sd=0.15) 70 minutes after beginning the experiment, which is 20 minutes later than the control zone. Also, the maximum runoff intensity of the experiment zone was 79.6% lower than that of the control zone, which confirmed that vegetation unit-type LID system had rainfall runoff reduction and delay effects. Based on the above findings, the reliability of a lab-level rainfall simulator for monitoring the vegetation-based LID system was reviewed, and maximum runoff intensity reduction and runoff time delay were confirmed. As a result, the study presented a performance evaluation method that can be applied to the pre-design of the vegetation-based LID system for rainfall events on a location before construction.

Absorptive material arrangement to make a quiet zone in a three dimensional enclosure (실내 정숙 공간 형성을 위한 흡음재 배치 방법)

  • 박주배;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1061-1066
    • /
    • 2002
  • This study proposes an analytic method that determines an optimal arrangement of absorptive materials on an enclosure surface. Under the optimal arrangement, a quiet zone in the enclosure has the minimum $\varepsilon$$\sub$p/ (acoustic potential energy density). The proposed method has been implemented by using a BEM simulation and a genetic algorithm. The BEM simulation evaluates the $\varepsilon$$\sub$p/ under the prescribed arrangement of the absorptive materials. The genetic algorithm searches the optimal arrangement by referring the ep evaluated from the BEM simulation. In the BEM simulation, the absorptive material arrangement is expressed as a vector, which is denoted as in absorptive material arrangement (AMA) vector. Besides, an admittance vector of which elements are admittances of available absorptive materials and an AMA matrix that transforms the admittance vector into the AMA vector are defined. The AMA matrix is also used as a chromosome in the genetic algorithm so that it functions to relate the BEM simulation to the genetic algorithm. As a verification example, the proposed method is applied to make the quiet zone in a parallelepiped enclosure.

  • PDF

Power Quality Optimal Control of Railway Static Power Conditioners Based on Electric Railway Power Supply Systems

  • Jiang, Youhua;Wang, Wenji;Jiang, Xiangwei;Zhao, Le;Cao, Yilong
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1315-1325
    • /
    • 2019
  • Aiming at the negative sequence and harmonic problems in the operation of railway static power conditioners, an optimization compensation strategy for negative sequence and harmonics is studied in this paper. First, the hybrid RPC topology and compensation principle are analyzed to obtain different compensation zone states and current capacities. Second, in order to optimize the RPC capacity configuration, the minimum RPC compensation capacity is calculated according to constraint conditions, and the optimal compensation coefficient and compensation angle are obtained. In addition, the voltage unbalance ${\varepsilon}_U$ and power factor requirements are satisfied. A PSO (Particle Swarm Optimization) algorithm is used to calculate the three indexes for minimum compensating energy. The proposed method can precisely calculate the optimal compensation capacity in real time. Finally, MATLAB simulations and an experimental platform verify the effectiveness and economics of the proposed algorithm.