• Title/Summary/Keyword: Minimum Temperature

Search Result 2,213, Processing Time 0.033 seconds

Effect of open space on the temperature drop -on Syakujii park of Tokyo in Japan- (공원녹지가 기온저하에 미치는 영향 -일본 동경부 석신정 공원을 중심으로-)

  • 윤용한;김은일;송태갑
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.259-268
    • /
    • 1998
  • This study was carried out to evaluate the effect of open space on temperature chang. In open space, lower temperature zones were formed, while high temperature zones were developed around urban areas. In forests and on water within open space, marked temperature reduction was recorded. The 10 % increase of the ratio of green space within fifty meters around the observation point decreased 0.33~0.43$^{\circ}C$ from the maximum temperature and 0.20~0.$25^{\circ}C$ from the minimum temperature. The increase of ten trees in the area decreased 0.33~0.49$^{\circ}C$ from the maximum temperature and 0.20~0.23$^{\circ}C$ from the minimum temperature.

  • PDF

A Study on Correlation of Outdoor Environmental Condition about Cooling Load (냉방부하에 영향을 미치는 외기 환경조건의 상관관계에 관한 연구)

  • Lee, Je-Myo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.759-766
    • /
    • 2012
  • To estimate the cooling load for the following day, outdoor temperature and humidity are needed in hourly base. But the meteorological administration forecasts only maximum and minimum temperature. New methodology is proposed for predicting hourly outdoor temperature and humidity by using the forecasted maximum and minimum temperature. The correlations for normalized outdoor temperature and specific humidity has been derived from the weather data for five years at Seoul, Daejeon and Pusan. The correlations for normalized temperature are independent of date, while the correlations for specific humidity are linearly dependent on date. The predicted results show fairly good agreement with the measured data. The prediction program is also developed for hourly outdoor dry bulb temperature, specific humidity, dew point, relative humidity, enthalpy and specific volume.

The Impacts of Urbanization on Changes of Extreme Events of Air Temperature in South Korea (한국의 도시화에 의한 극한기온의 변화)

  • Lee, Seung-Ho;Heo, In-Hye
    • Journal of the Korean Geographical Society
    • /
    • v.46 no.3
    • /
    • pp.257-276
    • /
    • 2011
  • This study aimed to analyze the changes of extreme temperature indices in order to investigate impacts of urbanization on changes of extreme temperature. It was analyzed 16 indices related to extreme temperature indices to 60 weather stations in South Korea. Extreme temperature indices-related summer mostly increased, and its related to winter decreased. Percentile-based indices were clearly increased more than fixed-based indices as a tropical night. Decreasing trend of extreme temperature indices related to winter had more clear than increasing trend of extreme temperature indices related to summer. It was similar to trend that urban temperature was more clearly increased in winter than summer. Decreasing trend of indices-related daily minimum temperature had more clear than increasing trend of indices-related daily maximum temperature. Also, it was similar to increasing trend of minimum temperature had more clear than maximum temperature.

A Study on The Effect of Humidity and Temperature of Hydroxy Propyl Methyl Cellulose Dust (Hydroxy Propyl Methyl Cellulose 분진의 습도와 온도에 대한 영향성 연구)

  • Lim Woo-Sub;Mok Yun-Soo;Choi Jae-Wook
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.3 s.67
    • /
    • pp.65-69
    • /
    • 2004
  • This study was performed with Hartmann type dust explosion apparatus and Godbert-Greenwald furnace apparatus in order to research the effect of temperature and humidity affecting LEL, minimum ignition temperature of Hydroxy Propyl Methyl Cellulose. The experimental determinations in the range between $20^{\circ}C\;and\;60^{\circ}C$ of temperature was not affected $LEL(180g/m^3)$ but LEL showed $200g/m^3\;and\;250g/m^3\;at\;80^{|circ}C\;and\;100^{\circ}C$. As the change of humidity LEL was $180g/m^3\;for\;50\%,\;200g/m^3\;for\;60\%\;and\;250g/m^3\;for\;70\%$ but dust explosion didn't occur over $80\%$. The ignition temperature of HPMC dust clouds was increased as increasing of humidity. So, the minimum ignition temperatures at $50\%,\;60\%,\;70\%\;80\%$ of humidity was $363^{\circ}C,\;375^{\circ}C,\;397^{\circ}C,\;405^{\circ}C$.

Implementing the Urban Effect in an Interpolation Scheme for Monthly Normals of Daily Minimum Temperature (도시효과를 고려한 일 최저기온의 월별 평년값 분포 추정)

  • 최재연;윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.4
    • /
    • pp.203-212
    • /
    • 2002
  • This study was conducted to remove the urban heat island effects embedded in the interpolated surfaces of daily minimum temperature in the Korean Peninsula. Fifty six standard weather stations are usually used to generate the gridded temperature surface in South Korea. Since most of the weather stations are located in heavily populated and urbanized areas, the observed minimum temperature data are contaminated with the so-called urban heat island effect. Without an appropriate correction, temperature estimates over rural area or forests might deviate significantly from the actual values. We simulated the spatial pattern of population distribution within any single population reporting district (city or country) by allocating the reported population to the "urban" pixels of a land cover map with a 30 by 30 m spacing. By using this "digital population model" (DPM), we can simulate the horizontal diffusion of urban effect, which is not possible with the spatially discontinuous nature of the population statistics fer each city or county. The temperature estimation error from the existing interpolation scheme, which considers both the distance and the altitude effects, was regressed to the DPMs smoothed at 5 different scales, i.e., the radial extent of 0.5, 1.5, 2.5, 3.5 and 5.0 km. Optimum regression models were used in conjunction with the distance-altitude interpolation to predict monthly normals of daily minimum temperature in South Korea far 1971-2000 period. Cross validation showed around 50% reduction in terms of RMSE and MAE over all months compared with those by the conventional method.conventional method.

A Study on Dielectric Properties of PCW-PNN-PZT ceramics (PCW-PNN-PZT계 세라믹의 유전 특성에 관한 연구)

  • Shin, Hye-Gyeong;Lee, Sung-Ho;Jung, Bo-Ram;Bae, Seon-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.51-53
    • /
    • 2005
  • This study was to measure the minuteness structure, dielectric properties of 0.03PCW-0.07PNN-0.9PZT ceramics according to sintering temperature manufacture the specimens with a general method. The results of this study were gotten such as follows. The crystal structure of ceramic changed the rombohedral structure into teteragonal structure according to rising sintering temperature in XRD. Dielectric constant at $20^{\circ}C$ showed its maximum value 510.599 in specimens sintered at $1100^{\circ}C$ and dielectric loss showed its minimum value 7.43% in specimens sintered at $1100^{\circ}C$. The variation rate of dielectric constant according to the change of frequency showed its minimum value 0.029/kHz at $1100^{\circ}C$. The variation rate of dielectric constant according to the change of temperature showed its minimum value $1.40/^{\circ}C$ at $1500^{\circ}C$.

  • PDF

Relationship Between the Minimum Ignition Energy(MIE) and the Temperature (최소발화에너지와 온도의 관계)

  • 하동명
    • Fire Science and Engineering
    • /
    • v.11 no.2
    • /
    • pp.3-10
    • /
    • 1997
  • Attempts are being made to investigate temperatures dependence of minimum ignition energy (MIE) based on concept of quantity of heat and thermal ignition theory. Regression equations for predicting MIE by means of temperature variations on the basis of statistical and mathematical methods are proposed. This study is undertaken to learn what proposed method is satisfactory hydrocarbons(propane and pentane). The proposed method has been tested and compared sucessfully with previously reported data in various journal.

  • PDF

Temperature and Atmosphere Dependence of the Electrical Conduction of the Vacuum Evaporated Thin Metal Films on Glass Substrate (진공증착된 금속박막의 전기전도성에 대한 온도와 분위기 의존성)

  • 김명균;박현수
    • Journal of the Korean Ceramic Society
    • /
    • v.28 no.6
    • /
    • pp.437-442
    • /
    • 1991
  • Temperature and atmosphere dependence of electrical conduction of the metal Cu, Ag, Au films, vaccum evaporated on glass, was investigated. The structural changes of the metal films were examined by SEM and high temperature XRD. The electrical resistance slightly increased with initial temperature increase up to the inflection point and decreased to minimum value, after this rapidly increased with further temperature increased below minimum. These phenomena were caused by the thermally induced film failure as a result of the mass transport. The temperature for the film failure increased in the order of O2, Air, Vacuum, N2, Ar in Cu, Ag films and Air, Vacuum, N2, Ar in Au film. The increase of resistance at the lower temperature range was attributed to the lattice distortion by disordered crystal structure, while the decreasing resistance was attributed to the removal of structural defects and film densification.

  • PDF

Ignition Temperature of Hydrogen/Air Mixture by Hot Wire in Pipeline (열선에 의한 파이프라인내의 수소/공기 혼합기의 착화온도)

  • Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.8-13
    • /
    • 2014
  • In order to improve safety for hydrogen network infrastructure, the ignition temperature by hot wire was investigated for different hydrogen compositions in pipelines. The result shows that minimum temperature for ignition decreased with decreasing hydrogen composition. The minimum temperature was confirmed at a hydrogen composition of approximately 10 vol.%. The one of the reasons is supposed that buoyancy force should generate the convection of gas mixture. It was also found that humidity had a little effect on ignition temperature, flame temperature.

Year-to-year Variability of the Vertical Temperature Structure in the Youngsan Estuary

  • Cho, Yang-Ki;Lee, Kyeong-Sig;Park, Kyung-Yang
    • Ocean and Polar Research
    • /
    • v.31 no.3
    • /
    • pp.239-246
    • /
    • 2009
  • Long-term observations were conducted between 1997 and 2002 to examine the variability of the vertical temperature structure in the Youngsan Estuary, southwest Korea, in summer. The observed hydrographic data revealed that the temperature minimum layer in the middle depth persisted through the entire summer of 2000 but was rarely observed in other years. The variability in the vertical structure might be affected by the air temperature during the previous winter and the density difference between the open sea and the estuary. In 2000, the air temperature in the previous winter was lowest and the horizontal density difference during summer was largest. The large horizontal density difference probably produced more active driving of warm water along the bottom, which would have intruded into the Youngsan Estuary. Furthermore, the cold previous winter would have provided a better condition for maintaining cold temperatures in the middle water layer for a longer period.