• Title/Summary/Keyword: Minimum Temperature

Search Result 2,213, Processing Time 0.034 seconds

Effect of Environmental Conditions on Estimation of Ambient Temperature for Minimum Postmortem Interval (PMI) in Korea (사후 경과시간 추정을 위한 현장 대기온도 예측에 국내 환경 조건이 미치는 영향)

  • Jeong, Su Jin;Park, Ji Eun;Lee, Hyo Jung;Park, Seong Hwan;Shin, Sang Eon;Lee, Jae Won
    • Journal of Science Criminal Investigation
    • /
    • v.11 no.3
    • /
    • pp.178-185
    • /
    • 2017
  • It is one of the most important factors to statistical estimation of ambient temperature for accumulated degree day (ADD) and minimum postmortem interval (PMI) in the incident scene. Until now, we applied the temperature of the nearest weather stations, adjusted temperature, or estimated the temperature by the linear regression analysis to estimate the temperature of the incident site. At this time, the estimated temperature may be changed according to the method of temperature estimation. And The accuracy of the estimated value may also vary depending on the environmental factors such as capacity, wind speed, humidity, and rainfall, which may affect measurement conditions and temperature. Therefore, we studied the effect of various environmental factors and measurement conditions for ambient temperature in Korea.

Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$ (한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계)

  • Chung, Kwan-Ogg;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

Correlation Analysis between Terra/Aqua MODIS LST and Air Temperature: Mainly on the Occurrence Period of Heat and Cold Waves (Terra/Aqua MODIS LST와 기온과의 상관성 분석: 한파 및 폭염 발생 기간을 중심으로)

  • CHUNG, Jee-Hun;LEE, Yong-Gwan;LEE, Ji-Wan;KIM, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.4
    • /
    • pp.197-214
    • /
    • 2019
  • In this study, the correlation analysis was conducted between observed air temperature (maximum, minimum, and mean air temperature) and the daytime and nighttime data of Terra/Aqua MODIS LST(Moderate Resolution Imaging Spectroradiometer Land Surface Temperature) for 86 weather stations. All the data of the recent 11 years from 2008 to 2018 were prepared with daily base. In particular, the characteristics of the cold and heat waves incidence period in 2018 were analyzed. The correlation analysis was performed using the Pearson correlation coefficient(R) and root mean square error(RMSE). As a result of time series analysis, the trend between observed air temperature and MODIS LST were similar, showing the correlation above 0.9 in maximum temperature, above 0.8 in mean and minimum temperature. Especially, the maximum temperature was found to have the highest accuracy with Terra MODIS LST daytime, and the minimum temperature had the highest correlation with Terra MODIS LST nighttime. During the cold wave period, both Terra and Aqua MODIS LST showed higher correlations with nighttime data than daytime data. For the heat wave period, the Aqua MODIS LST daytime data was good, but the overall R was below 0.5. Additional analysis is necessary for further study considering such as land cover and elevation characteristics.

Estimation of Duration of Low-temperature in Winter Season Using Minimum Air Temperature on January (1월 최저기온을 이용한 겨울철 저온발생일수 추정)

  • Moon, Kyung-Hwan;Son, In-Chang;Seo, Hyeong-Ho;Choi, Kyung-San;Joa, Jae-Ho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.3
    • /
    • pp.119-123
    • /
    • 2012
  • The duration of low temperature in winter season is one of the important agrometeorological characteristics in crop growing fields. This study was conducted to develop a method to estimate the duration of low-temperature with monthly meteorological data. Using daily meteorological data from 61 observation sites from 1981 to 2010, we analyzed the relationships between the averages of monthly temperature minima and the durations of low-temperature ranging from -15 to $5^{\circ}C$, The monthly mean of the January minimum air temperature was appropriate for theestimation of the durations of lowtemperature below $0^{\circ}C$. We tested a simple second order equation to predict durations of low-temperature. To apply the equation to various temperature ranges, we suggested two different equations for the estimation of coefficients a and b, which are dependent on the base temperatures from -15 to $0^{\circ}C$. Thevalidation of the equations using other daily meteorological datasets from 1971 to 2000 showed that they were appropriate for the range from -10 to $0^{\circ}C$, but underestimated at $-15^{\circ}C$.

A Study on the Stability of High Density SRAM Cell) (고집적 SRAM Cell의 동작안정화에 관한 연구)

  • Choi, Jin-Young
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.11
    • /
    • pp.71-78
    • /
    • 1995
  • Based on the popular 4-transistor SRAM cell, an analytical expression of the minimum cell ratio was derived by modeling the static read operation. By analyzing the relatively simple expression for the minimum cell ratio, which was derived assuming the ideal transistor characteristics, effects of the changes in supply voltage and process parameters on the minimum cell ratio was predicted, and the minimum power supply voltage for read operation was determined. The results were verified by simulations utilizing the suggested simulation method, which is suitable for monitoring the lower limit of supply voltage for proper cell operation. From the analysis, it was shown that the worst condition for cell operation is low temperature and low supply voltage, and that the operation margin can be effectively improved by reducing the threshold voltage of the cell transistors.

  • PDF

Hydrodynamic Analysis of Piston Rings (피스톤 링의 유체 윤활 해석)

  • 김재현;최상민;김경웅
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.167-172
    • /
    • 1998
  • An algorithm of Thermal-elastohydrodynamic lubrication analysis for the piston ring is developed. This algorithm contains cavitation boundary condition so it automatically satisfies conservation of mass. 1-D Reynolds equation and 2-D energy equation are solved simultaneously by using Gauss-Jordan method and Newton-Raphson method. Minimum film thickness and friction force are calculated for 1 cycle. There is little difference between the results caculated by isothermal rigid and EHL analysis in entire cycle. In the results of THL, shear heating effect and temperature boundary condition affect the minimum film thickness and friction force prediction. The minimum film thickness and the friction force calculated by THL are lower than those caculated using isothermal assumption.

  • PDF

액막류의 MHF점에 관한 실험적 연구

  • 김영찬;서태원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.960-965
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increases with increasing the velocity and the subcooling of the liquid film flow.

  • PDF

Thermal Analysis of Composite Satellite Antenna Structure in Space Environment (복합재 통신위성 안테나의 우주환경 열해석)

  • ;;;;Frank Gilles
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.77-80
    • /
    • 2002
  • Thermal analysis has been performed to evaluate the thermal effect on composite antenna (Ka-band) structure in space environment. The concepts of thermal control are also presented to maintain the antenna components within respective temperature limits. A steady-state algorithm of I-DEAS' thermal analysis software was utilized to predict both maximum and minimum temperature, maximum gradient temperature, and temperature distribution on each antenna component.

  • PDF