• 제목/요약/키워드: Minimally invasive surgery procedure

검색결과 170건 처리시간 0.024초

경피적 최소침습 척추시술 중 디스크 내에서 방향제어가 가능한 Bio-SMA 캐뉼라 카테터의 개발 (Development of Controllable Cannular Catheter using Bio Shape Memory Alloy (SMA) during Percutaneous Minimally Invasive Spine Surgery)

  • 김철웅
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.378-383
    • /
    • 2007
  • As the Minimally Invasive Surgery (MIS) is developed, an interventional procedure becomes the major of the spine surgery in the world. Despite of the use of the expensive medical equipments, the success chance of the nucleoplasty is about 30%. The reason is that the shape of the cannular needle is similar to that of the conventional injector and looks like the straight. Because the tip of these straight needles is not able to reach in the vicinity of the disc bulging or the protrusion, which are the cause of the low back pain and because the far indirect plasma discharge results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body cannula device. If 3-D direction controllable cannular catheter (whose direction is accurately controlled after inserting into the bodies to cure the lesion) is developed, it is expected that new devised cannular catheter can cure many incurable diseases simultaneously. Therefore, the aims of this research are to develop the new devised cannular catheter of SMA direction controller for the medical situation, which has been produced through many previous trial-error procedures, and to produce the commercial medical device.

  • PDF

최소 침습 기법 슬개건 부하 분산 봉합술과 유관 나사못을 이용한 슬개골 횡골절의 치료 (Treatment of Transverse Patella Fracture with Minimally Invasive Load-Sharing Patellar Tendon Suture and Cannulated Screws)

  • 이범석;박병문;양봉석;김규완
    • 대한정형외과학회지
    • /
    • 제56권6호
    • /
    • pp.540-545
    • /
    • 2021
  • 슬개골 횡골절은 수술이 필요한 전위된 슬개골 골절의 가장 흔한 형태이다. 이러한 슬개골 횡골절은 골절선을 지나 평행하게 삽입된 Kirschner-강선이나 나사못에 장력대 강선을 추가적으로 고정한 기법이 흔히 사용된다. 그러나 고식적인 고정 방법의 경우 삽입된 강선이나 핀의 돌출에 의한 합병증이 흔히 발생한다. 이러한 합병증은 내고정물의 제거를 위한 추가적인 수술을 필요로 하고, 의료비 상승 및 슬관절의 기능 제한을 일으킬 수 있다. 이에 슬개골 횡골절에 대해 안정적인 고정력을 제공하고 수술 시 연부조직 손상을 최소화하여 골절부 혈류를 보존하고 수술 후 통증을 감소시키며, 내고정물에 의한 자극과 그에 따른 통증을 감소시켜 관절 운동 제한 발생 위험을 감소 시키는 최소 침습 부하 분산 경피적 슬개건 봉합술을 이용하여 치료한 사례들을 수술 술기와 함께 보고하고자 한다.

Clinical Outcomes of Minimally Invasive Surgical Stabilization of Rib Fractures Using Video-Assisted Thoracoscopic Surgery

  • Chae-Min Bae;Shin-Ah Son;Yong Jik Lee;Sang Cjeol Lee
    • Journal of Chest Surgery
    • /
    • 제56권2호
    • /
    • pp.120-125
    • /
    • 2023
  • Background: Multiple rib fractures are common in blunt chest trauma. Until recently, most surgical rib fixations for multiple rib fractures were performed via open thoracotomy. However, due to the invasive nature of tissue dissection and the resulting large wound, an alternative endoscopic approach has emerged that minimizes the postoperative complications caused by the manipulation of injured tissue and lung during an open thoracotomy. Methods: Our study concentrated on patients with multiple rib fractures who underwent surgical stabilization of rib fractures (SSRF) between June 2018 and May 2020. We found 27 patients who underwent SSRF using video-assisted thoracoscopic surgery. The study design was a retrospective review of the patients' charts and surgical records. Results: No intraoperative events or procedure-related deaths occurred. Implant-related irritation occurred in 4 patients, and 1 death resulted from concomitant trauma. The average hospital stay was 30.2±20.1 days, and ventilators were used for 12 of the 22 patients admitted to the intensive care unit. None of the patients experienced major pulmonary complications such as pneumonia or acute respiratory distress syndrome. Conclusion: Minimally invasive rib stabilization surgery with the assistance of a thoracoscope is expected to become more widely used in patients with multiple rib fractures. This method will also assist patients in a quick recovery.

심방세동의 최신 외과적 치료 (Recent Advances in Surgery for Atrial Fibrillation)

  • 이동협;정태은
    • Journal of Yeungnam Medical Science
    • /
    • 제22권1호
    • /
    • pp.13-26
    • /
    • 2005
  • Atrial fibrillation (AF) is the most common cardiac rhythm disturbance, which carries significant cardiovascular morbidity and mortality. The medical treatment for AF is cumbersome and unsatisfactory, which has highlighted the need to develop alternative treatments for AF. The recent discovery that AF is often initiated by atrial ectopic beats has resulted in treatments designed to target the ectopic sources, particularly those within the pulmonary veins. Building on the pioneering work of Cox et al., a recent reported series demonstrated the feasibility of treating patients undergoing cardiac surgery for other structural heart diseases with limited, left-atrial ablation lesion sets using alternative energy sources. As less complex modifications of the Maze procedure have been developed, a number of energy sources have been introduced to create of electrically isolating lesions within the atria. These sources have been used both endocardially in arrest heart procedures as well as epicardially in a beating heart setting. This review summarizes the recent advances in surgery for AF that will aid in the development of an effective, minimally invasive surgical procedure to cure patients with AF.

  • PDF

Robot-Assisted Cardiac Surgery Using the Da Vinci Surgical System: A Single Center Experience

  • Kim, Eung Re;Lim, Cheong;Kim, Dong Jin;Kim, Jun Sung;Park, Kay Hyun
    • Journal of Chest Surgery
    • /
    • 제48권2호
    • /
    • pp.99-104
    • /
    • 2015
  • Background: We report our initial experiences of robot-assisted cardiac surgery using the da Vinci Surgical System. Methods: Between February 2010 and March 2014, 50 consecutive patients underwent minimally invasive robot-assisted cardiac surgery. Results: Robot-assisted cardiac surgery was employed in two cases of minimally invasive direct coronary artery bypass, 17 cases of mitral valve repair, 10 cases of cardiac myxoma removal, 20 cases of atrial septal defect repair, and one isolated CryoMaze procedure. Average cardiopulmonary bypass time and average aorta cross-clamping time were $194.8{\pm}48.6$ minutes and $126.1{\pm}22.6$ minutes in mitral valve repair operations and $132.0{\pm}32.0$ minutes and $76.1{\pm}23.1$ minutes in myxoma removal operations, respectively. During atrial septal defect closure operations, the average cardiopulmonary bypass time was $128.3{\pm}43.1$ minutes. The median length of stay was between five and seven days. The only complication was that one patient needed reoperation to address bleeding. There were no hospital mortalities. Conclusion: Robot-assisted cardiac surgery is safe and effective for mitral valve repair, atrial septal defect closure, and cardiac myxoma removal surgery. Reducing operative time depends heavily on the experience of the entire robotic surgical team.

Feasibility of the AtriClip Pro Left Atrium Appendage Elimination Device via the Transverse Sinus in Minimally Invasive Mitral Valve Surgery

  • Shirasaka, Tomonori;Kunioka, Shingo;Narita, Masahiko;Ushioda, Ryohei;Shibagaki, Keisuke;Kikuchi, Yuta;Wakabayashi, Naohiro;Ishikawa, Natsuya;Kamiya, Hiroyuki
    • Journal of Chest Surgery
    • /
    • 제54권5호
    • /
    • pp.383-388
    • /
    • 2021
  • Background: Achieving external access to and manual occlusion of the left atrial appendage (LAA) during minimally invasive mitral valve surgery (MIMVS) through a small right thoracotomy is difficult. Occlusion of the LAA using an epicardial closure device seems quite useful compared to other surgical techniques. Methods: Fourteen patients with atrial fibrillation underwent MIMVS with concomitant surgical occlusion of the LAA using double-layered endocardial closure stitches (n=6, endocardial suture group) or the AtriClip Pro closure device (n=8, AtriClip group) at our institution. The primary safety endpoint was any device-related adverse event, and the primary efficacy endpoint was successful complete occlusion of blood flow into the LAA as assessed by transthoracic echocardiography at hospital discharge. The primary efficacy endpoint for stroke reduction was the occurrence of ischemic or hemorrhagic neurologic events. Results: All patients underwent LAA occlusion as scheduled. The cardiopulmonary bypass and aortic cross-clamp times in the endocardial suture group and the AtriClip group were 202±39 and 128±41 minutes, and 213±53 and 136±44 minutes, respectively (p=0.68, p=0.73). No patients in either group experienced any device-related serious adverse events, incomplete LAA occlusion, early postoperative stroke, or neurologic complication. Conclusion: Epicardial LAA occlusion using the AtriClip Pro during MIMVS in patients with mitral valve disease and atrial fibrillation is a simple, safe, and effective adjunctive procedure.

최소침습 방사능 유도 부갑상선 수술 (Minimally Invasive Radio-guided Parathyroid Surgery)

  • 정웅윤;장항석;이종두;박정수
    • 대한두경부종양학회지
    • /
    • 제15권2호
    • /
    • pp.194-199
    • /
    • 1999
  • Introduction: Since 1996, Dr. James Norman has successfully performed mimimally invasive radio-guided parathyroidectomy(MIRP) using intraoperative nuclear mapping with $^{99m}Tc$ sestamibi scanning and radioactivity detection probe. Objectives: We aimed to introduce this new surgical technique and evaluate it's efficacy by our own experiences. Method: From May to October 1999, five consecutive patients with primary hyperparathyroidism underwent parathyroidectomy by using modified MIRP technique. $^{99m}Tc$ sestamibi scanning was performed 1.0 or 1.5 hour before operation. After intraoperative localization of the tumor under the guidance of quantitative gamma counting with a NEVIGATOR probe, an unilateral small skin incision(3.0-4.0cm) was placed. Without a skin flap, the strap muscle was directly divided with the use of a Harmonic scalpel. After careful dissection, the parathyroid tumor was removed. Result: In all patients, a single adenoma could be easily detected and removed by this new technique. Mean incision length was 3.2cm(3.0-4.0cm) and operative time ranged from 40 to 110minute. All the patients were discharged within 2 days of surgery without any complication. Conclusion: This new operative technique could become the most minimally invasive alternative to the standard operative procedure for parathyroid adenoma.

  • PDF

Minimally Invasive Multi-Level Posterior Lumbar Interbody Fusion Using a Percutaneously Inserted Spinal Fixation System : Technical Tips, Surgical Outcomes

  • Kim, Hyeun-Sung;Park, Keun-Ho;Ju, Chag-Il;Kim, Seok-Won;Lee, Seung-Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권5호
    • /
    • pp.441-445
    • /
    • 2011
  • Objective : There are technical limitations of multi-level posterior pedicle screw fixation performed by the percutaneous technique. The purpose of this study was to describe the surgical technique and outcome of minimally invasive multi-level posterior lumbar interbody fusion (PLIF) and to determine its efficacy. Methods : Forty-two patients who underwent mini-open PLIF using the percutaneous screw fixation system were studied. The mean age of the patients was 59.1 (range, 23 to 78 years). Two levels were involved in 32 cases and three levels in 10 cases. The clinical outcome was assessed using the visual analog scale (VAS) and Low Back Outcome Score (LBOS). Achievement of radiological fusion, intra-operative blood loss, the midline surgical scar and procedure related complications were also analyzed. Results : The mean follow-up period was 25.3 months. The mean LBOS prior to surgery was 34.5, which was improved to 49.1 at the final follow up. The mean pain score (VAS) prior to surgery was 7.5 and it was decreased to 2.9 at the last follow up. The mean estimated blood loss was 238 mL (140-350) for the two level procedures and 387 mL (278-458) for three levels. The midline surgical scar was 6.27 cm for two levels and 8.25 cm for three level procedures. Complications included two cases of asymptomatic medial penetration of the pedicle border. However, there were no signs of neurological deterioration or fusion failure. Conclusion : Multi-level, minimally invasive PLIF can be performed effectively using the percutaneous transpedicular screw fixation system. It can be an alternative to the traditional open procedures.

Percutaneous two unilateral iliosacral S1 screw fixation for pelvic ring injuries: a retrospective review of 38 patients

  • Son, Whee Sung;Cho, Jae-Woo;Kim, Nam-Ryeol;Cho, Jun-Min;Choi, Nak-Jun;Oh, Jong-Keon;Kim, HanJu
    • Journal of Trauma and Injury
    • /
    • 제35권1호
    • /
    • pp.34-42
    • /
    • 2022
  • Purpose: Percutaneous iliosacral (IS) screw fixation for pelvic ring injuries is a minimally invasive technique that reduces the amount of blood loss and shortens the procedure time. Moreover, two unilateral IS S1 screws exhibit superior stability to a single IS screw and are also safer for neurological injuries than an S2 screw. Therefore, this study aimed to evaluate fixation using percutaneous two unilateral IS S1 screws for pelvic ring injuries and its subsequent clinical outcomes. Methods: We retrospectively reviewed 38 patients who underwent percutaneous two unilateral IS S1 screw fixation for pelvic ring injuries. The procedure time, blood loss, achievement of bone union, radiological outcomes (Matta and Tornetta grade), and postoperative complications were evaluated. Results: The mean procedure time, hemoglobin loss, bone union rate, and time to union were 40.1 minutes (range, 18-102 minutes), 0.6 g/dL (range, 0.3-1.0 g/dL), 100%, and 153.2 days (range, 61-327 days), respectively. The Matta and Tornetta grades were excellent, good, and fair in 24 (63.1%), 11 (28.9%), and three patients (7.9%), respectively, and the postoperative complications were S1 screw loosening, widening of the symphysis pubis (2.3 and 2.5 mm), lumbosacral plexopathy, and S1 radiculopathy in one (2.6%), two (5.3%), one (2.6%), and one patient (2.6%), respectively. However, all neurological complications recovered spontaneously. Conclusions: Percutaneous two unilateral IS S1 screw fixation was useful for treating pelvic ring injuries. In particular, it involved a short procedure time with little blood loss and also led to 100% bone union and good radiological outcomes.

Video-Assisted Thoracic Surgery Thymectomy: Transpleural Approach

  • Park, In Kyu
    • Journal of Chest Surgery
    • /
    • 제54권4호
    • /
    • pp.310-313
    • /
    • 2021
  • There are several types of minimally invasive approaches for thymectomy, of which the transpleural approach by video-assisted thoracoscopic surgery is particularly useful. In this approach, thymectomy is performed from either side of the thoracic cage. Thoracic surgeons should be familiar with the principles of the procedure, the anatomy of the region, and surgical strategies for successful thymectomy. The details of transpleural thymectomy are discussed herein.