• Title/Summary/Keyword: Minimally invasive robotic surgery

Search Result 51, Processing Time 0.029 seconds

Design and Performance Evaluation of Tactile Device Using MR Fluid (MR 유체를 이용한 촉감구현장치의 설계 및 성능 평가)

  • Kim, Jin-Kyu;Oh, Jong-Seok;Han, Young-Min;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.415-420
    • /
    • 2012
  • This paper proposes a novel type of tactile device utilizing magnetorheological (MR) fluid which can be applicable for haptic master of minimally invasive surgery (MIS) robotic system. The salient feature of the controllability of rheological properties by the intensity of the magnetic field (or current) makes this potential candidate of the tactile device. As a first step, an appropriate size of the tactile device is designed and manufactured via magnetic analysis. Secondly, in order to determine proper input magnetic field the repulsive forces of the real body parts such as hand and neck are measured. Subsequently, the repulsive forces of the tactile device are measured by dividing 5 areas. The final step of this work is to obtain desired force in real implementation. Thus, in order to demonstrate this goal a neuro-fuzzy logic is applied to get the desired repulsive force and the error between the desired and actual force is evaluated.

  • PDF

Feasibility and Safety of Robotic Surgery for Gynecologic Cancers

  • Manchana, Tarinee;Sirisabya, Nakarin;Vasuratna, Apichai;Termrungruanglert, Wichai;Tresukosol, Damrong;Wisawasukmongchol, Wirach
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5359-5364
    • /
    • 2014
  • Background: To determine surgical outcomes, perioperative complications, and patient outcomes in gynecologic cancer patients undergoing robotic surgery. Materials and Methods: Surgical outcomes, including docking time, total operative time, console time, estimated blood loss (EBL), conversion rate and perioperative complications were retrospectively reviewed in 30 gynecologic cancer patients undergoing robotic surgery. Patient outcomes included recovery time and patient satisfaction, as scored by a visual analogue scale (VAS) from 0-10. Results: The operations included 24 hysterectomies with pelvic lymphadenectomy (PLD) and/or para-aortic lymphadenectomy, four radical hysterectomies with PLD, and two radical trachelectomies with PLD. Mean docking time was $12.8{\pm}9.7min$, total operative time was $345.5{\pm}85.0min$, and console time was $281.9{\pm}78.6min$. These times were decreased in the second half of the cases. There was no conversion rate. Three intraoperative complications, including one external iliac artery injury, one bladder injury, and one massive bleeding requiring blood transfusion were reported. Postoperative complications occurred in eight patients, most were minor. Only one patient had port herniation that required reoperation. Mean hospital stay was $3.5{\pm}1.7days$, and recovery time was $14.2{\pm}8.1days$. Two-thirds of patients felt very satisfied and one-third felt satisfied; the mean satisfaction score was 9.4 +0.9. Two patients with stage III endometrial cancer developed isolated port site metastasis at five and 13 months postoperatively. Conclusions: Robotic surgery for gynecologic cancer appears to be feasible, with acceptable perioperative complication rate, fast recovery time and high patient satisfaction.

D2 Lymph Node Dissections during Reduced-port Robotic Distal Subtotal Gastrectomy and Conventional Laparoscopic Surgery Performed by a Single Surgeon in a High-volume Center: a Propensity Score-matched Analysis

  • Song, Jeong Ho;Son, Taeil;Lee, Sejin;Choi, Seohee;Cho, Minah;Kim, Yoo Min;Kim, Hyoung-Il;Hyung, Woo Jin
    • Journal of Gastric Cancer
    • /
    • v.20 no.4
    • /
    • pp.431-441
    • /
    • 2020
  • Purpose: Various studies have indicated that reduced-port robotic gastrectomies are safe and feasible for treating patients with early gastric cancer. However, there have not been any comparative studies conducted that have evaluated patients with clinically advanced gastric cancer. Therefore, we aimed to compare the perioperative outcomes of D2 lymph node dissections during reduced-port robotic distal subtotal gastrectomies (RRDGs) and conventional 5-port laparoscopic distal subtotal gastrectomies (CLDGs). Materials and Methods: We retrospectively evaluated 118 patients with clinically advanced gastric cancer who underwent minimally invasive distal subtotal gastrectomies with D2 lymph node dissections between February 2016 and November 2019. To evaluate the patient data, we performed a 1:1 propensity score matching (PSM) according to age, sex, body mass index, American Society of Anesthesiologists physical status classification score, and clinical T status. The short-term surgical outcomes were also compared between the two groups. Results: The PSM identified 40 pairs of patients who underwent RRDG or CLDG. The RRDG group experienced a significantly longer operation time than the CLDG group (P<0.001), although the RRDG group had significantly less estimated blood loss (P=0.034). The number of retrieved extraperigastric lymph nodes in the RRDG group was significantly higher than that of the CLDG group (P=0.008). The rate of postoperative complications was not significantly different between the two groups (P=0.115). Conclusions: D2 lymph node dissections can be safely performed during RRDGs and the perioperative outcomes appear to be comparable to those of conventional laparoscopic surgeries. Further studies are needed to compare long-term survival outcomes.

The First 20 Cases of Cardiac Surgery Using the da $Vinci^{TM}$ Surgical System: A Single Center Experience (다빈치 수술로봇을 이용한 심장수술 20예 보고 - 단일 기관 보고 -)

  • Je, Hyoung-Gon;Lee, Yong-Jik;Jung, Sung-Ho;Jung, Jae-Seung;Kang, Pil-Je;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.423-429
    • /
    • 2008
  • Background: The interest in robotic cardiac surgery has recently grown but there has not been much clinical research reported on this. The aim of this study is to examine our initial experience, since August 2007, with robotic cardiac surgery using the da $Vince^{TM}$ surgical system and to evaluate the feasibility and safety of it. Material and Method: Between August and December 2007, a total of 20 patients underwent robotic cardiac surgery using the da Vinci surgical system. For mitral valve repair (n=11), tricuspid valve repair (n=1), and ASD repair (n=1), cannulation, antegrade cardioplegia and transthoracic aortic cross-clamping were conducted for the right femoral vessels and the right internal jugular vein. For minimally invasive direct CABG (MIDCAB) (n=7), the internal thoracic artery (ITA) was harvested with the da Vinci surgical system. Result: The mean age of the patients was 50.1 (range: $26{\sim}78$) years. Three concomitant Maze procedures and one tricuspid annuloplasty were combined with mitral valve repair. The mean cardiopulmonary bypass time was $208.0{\pm}61.3$ minutes and the aortic cross clamp time was $158.8{\pm}40.6$ minutes. No patients showed more than mild mitral regurgitation after repair and the median hospital stay was 4 days. The robotic-harvested ITA was used for either left ITA (n=6) or bilateral ITA (n=1). The mean harvest time was $43.2{\pm}12.0$ minutes. The harvested ITA showed good flow and it was anastomosed under direct vision after left anterolateral thoracotomy. The patency of all the grafts was 100% (18/18) in MIDCAB. Conclusion: Robotic cardiac surgery using the da Vinci surgical system was variously adapted to areas such as mitral and tricuspid valve repair, ASD repair and ITA harvest for MIDCAB. The early results of the robotic cardiac surgery showed its safety and feasibility. With this primary report, we anticipate that clinical applications and further studies on robotic cardiac surgery using the da Vinci surgical system will be actively conducted in Korea.

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.

Robot-Assisted Repair of Atrial Septal Defect: A Comparison of Beating and Non-Beating Heart Surgery

  • Yun, Taeyoung;Kim, Hakju;Sohn, Bongyeon;Chang, Hyoung Woo;Lim, Cheong;Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.55 no.1
    • /
    • pp.55-60
    • /
    • 2022
  • Background: Robot-assisted repair of atrial septal defect (ASD) can be performed under either beating-heart or non-beating-heart conditions. However, the risk of cerebral air embolism (i.e., stroke) is a concern in the beating-heart approach. This study aimed to compare the outcomes of beating- and non-beating-heart approaches in robot-assisted ASD repair. Methods: From 2010 to 2019, a total of 45 patients (mean age, 43.4±14.6 years; range, 19-79 years) underwent ASD repair using the da Vinci robotic surgical system. Twenty-seven of these cases were performed on a beating heart (beating-heart group, n=27) and the other cases were performed on an arrested or fibrillating heart (non-beating-heart group, n=18). Cardiopulmonary bypass (CPB) was achieved via cannulation of the femoral vessels and the right internal jugular vein in all patients. Results: Complete ASD closure was verified using intraoperative transesophageal echocardiography in all patients. Conversion to open surgery was not performed in any cases, and there were no major complications. All patients recovered from anesthesia without any immediate postoperative neurologic symptoms. In a subgroup analysis of isolated ASD patch repair (beating-heart group: n=22 vs. non-beating-heart group: n=5), the operation time and CPB time were shorter in the beating-heart group (234±38 vs. 253±29 minutes, p=0.133 and 113±28 vs. 143±29 minutes, p=0.034, respectively). Conclusion: Robot-assisted ASD repair can be safely performed with the beating-heart approach. No additional risk in terms of cerebral embolism was found in the beating-heart group.

Multi-vessel Small Thoracotomy (MVST) CABG with Robot-assisted Bilateral ITA Harvesting - A case report - (수술 로봇을 이용한 양측 내흉동맥 채취 후 시행한 최소 침습적 다혈관 관상동맥 우회술 - 1예 보고 -)

  • Chung, Jin-Woo;Lee, Jae-Won;Je, Hyoung-Gon
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.264-267
    • /
    • 2008
  • The da Vinci telemanipulator system (Intuitive Surgical, Sunnyvale, CA USA) is the most advanced robotic surgical system and has been increasingly used for cardiac surgical procedures. We report out first clinical experience of use of the da Vinci telemanipulator system for endoscopic harvesting of the bilateral thoracic artery andmulti-vessel small thoracotomy off pump CABG for 3-vessel disease. The da Vinci telemanipulator system has been previously utilized primarily for mitral valve surgery.

A Study on Safety and Performance Evaluation of Micro - surgical Robots Based on Open Robot Platform (개방형 로봇 플랫폼 기반 미세수술로봇의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.206-214
    • /
    • 2019
  • Surgical methods and associated precision systems have been developed, but surgical procedures that require precise location and fine manipulation of the lesion remain a limitation. The combination of precision robot manipulation technology and 3D medical image navigation technology overcomes the limitations of minimally invasive surgery (MIS) and enables a more stable and successful operation. Surgical robots are surgical robots such as da Vince, and surgical robots using industrial robotic arms. There are various developments and researches of medical robots. In recent medical robot development, a new type of surgical robot based on an industrial robot arm capable of easily replacing the end effector according to the user's needs is being actively developed at home and abroad. Therefore, in this study, we developed safety and performance evaluation guideline for micro - surgical robots based on open robot platform using general purpose robot arm to help quality control of the medical device.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

Minimal Invasive Surgery: A National Survey of Its Members by the Korean Association of Pediatric Surgeons (최소 침습 수술: 대한소아외과학회 회원을 대상으로 한 전국조사)

  • Kim, Dae Yeon;Kim, I.S.;Kim, H.Y.;Nam, S.H.;Park, K.W.;Park, W.H.;Park, Y.J.;Park, J.H.;Park, J.Y.;Park, J.S.;Park, J.Y.;Boo, Y.J.;Seo, J.M.;Seol, J.Y.;Oh, J.T.;Lee, N.H.;Lee, M.D.;Jang, J.H.;Jung, K.H.;Jung, S.Y.;Jung, S.E.;Jung, S.M.;Jung, E.Y.;Jung, J.H.;Cho, M.J.;Choi, K.J.;Choi, S.J.N.;Choi, S.O.;Choi, S.H.;Choi, Y.M.;Hong, J.
    • Advances in pediatric surgery
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Minimal invasive surgery (MIS) has rapidly gained acceptance for the management of a wide variety of pediatric diseases. A questionnaire was sent to all members of the Korean Association of Pediatric Surgeons. Thirty one members (25.4%) took part in the survey that included data for the year 2012: demographic details, opinion regarding minimal invasive surgery and robotic surgery, spectrum of minimally invasive operations, and quantity of procedures. 48.4% of the respondents had more than 10 years experience, 35.5% less than 10 years experience, and 16.1 % had no experience. The respondents of the recommend MIS and perform MIS for surgical procedures are as follow; inguinal hernia (61.3%), simple appendicitis (87.1%), complicated appendicitis (80.6%), reduction of intussusceptions (83.9%), pyloromyotomy (90.3%), fundoplication (96.8%), biopsy and corrective surgery of Hirschsprung's disease (93.5%/90.3%), imperforate anus (77.4%), congenital diaphragmatic hernia (80.6%), and esophageal atresia (74.2%). The MIS procedures with more than 70% were lung resection (100%), cholecystectomy (100%), appendectomy (96.2%), ovarian torsion (86.7%), fundoplication (86.8%), hiatal hernia repair (82.6%), and splenectomy (71.4%). The MIS procedures with less than 30% were congenial diaphragmatic hernia reapir (29.6%), esophageal atresia (26.2%), correction of malroatation (24.4%), inguinal hernia repair (11.4%), anorectal malformation (6.8%), Kasai operation (3.6%).