• Title/Summary/Keyword: Minimal-invasive

Search Result 199, Processing Time 0.024 seconds

TREATMENT OF CROWN-ROOT FRACTURE USING FIBER-REINFORCED POST: A CASE STUDY (섬유강화형 포스트를 이용한 치관-치근 파절의 치료: 증례 보고)

  • Lim, Hwa-Shin;La, Ji-Young;Lee, Kwang-Hee;An, So-Youn;Kim, Yun-Hee;Keum, Ki-Seok;Lee, Sang-Bong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.1
    • /
    • pp.58-65
    • /
    • 2012
  • The crown-root fracture is defined as a fracture of tooth that contains enamel, dentin and cementum with or without pulp exposure. Generally the fracture lines place obliquely from labial surface, between incisal edge of the crown and marginal gingiva, to palatal surface subgingivally. If the fracture line is located supragingivally, the removal of tooth fragment and supragingival restoration can be performed. In subgingival fracture line, the surgical exposure, orthodontic eruption or surgical eruption can be considered. If the fracture line is too deep to restorate, extraction or decoronation can be selected. In children and adolescents, the extraction should be the last option. Another option to select before extraction is the restoration using fiber-reinforced post and the reattachment of tooth fragment. The fiber-rainforced post enhances the retention and the durability of tooth fragment. The reattachment of crown fragment using resin adhesive system is considered minimal invasive treatment biologically. This case reports the treatment of crown-root fracture using the reattachment of crown fragment and the insertion of fiber-reinforced post.

Dislodgement resistance of modified resin-bonded fixed partial dentures utilizing tooth undercuts: an in vitro study

  • Doh, Re-Mee;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.85-90
    • /
    • 2009
  • STATEMENT OF PROBLEM. Over the years, resin-bonded fixed partial dentures (RBFPDs) have gone through substantial development and refinement. Several studies examined the biomechanics of tooth preparation and framework design in relation to the success rate of RBFPDs and considered retention and resistance form essential for increase of clinical retention. However, these criteria required preparations to be more invasive, which violates not only the original intentions of the RBFPD, but may also have an adverse effect on retention due to loss of enamel, an important factor in bonding. PURPOSE. The object of this in vitro study was to compare the dislodgement resistance of the new types of RBFPDs, the conventional three-unit fixed partial denture, and conventional design of RBFPD (Maryland bridge). MATERIAL AND METHODS. Fifty resin mandibular left second premolars and second molars were prepared on dentiforms, according to the RBFPD design. After model fabrication (five group, n = 10), prostheses were fabricated and cemented with zinc phosphate cement. After cementation, the specimens were subjected to tensile loading at a cross head speed of 4 mm/min in a universal testing machine. The separation load was recorded and analyzed statistically using one-way analysis of variance followed by Duncan's multiple range test. RESULTS. Group V, the pin-retained RBFPDs, had the highest mean dislodgement resistance, whereas specimens of group II, the conventional RBFPDs, exhibited a significantly lower mean dislodgement resistance compared to the other 4 groups (P <.05). There were no significant differences between group I, III, and IV in terms of dislodgement resistance (P>.05). Group V had the highest mean MPa (N/$mm^2$) (P <.05). There was no significant difference between groups I, II, III and IV (P > .05). CONCLUSION. Within the limits of the design of this in vitro study, it was concluded that: 1. The modified RBFPDs which utilizes the original tooth undercuts and requires no tooth preparation, compared with the conventional design of RBFPDs, has significantly high dislodgement resistance (P < .05). 2. The modified RBFPDs which utilizes the original tooth undercuts and requires minimal tooth preparation, compared with the conventional FPDs, has significantly no difference in retention and dislodgement resistance)(P>.05). 3. The pin-retained FPDs showed a high dislodgement resistance compared to the conventional three-unit FPDs (P<.05).

Operative Treatment of Tibial Plateau Fractures (경골과 골절의 수술적 치료 결과)

  • Shin, Duck-Seop;Seong, Byeong-Yeon;Kim, Dong-Won
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.187-198
    • /
    • 2001
  • Background: The purpose of this study was to evaluate the relationship between variable factors and clinical results following the operative treatment of the tibial plateau fractures. Materials and Methods: The clinical and radiological analysis was performed on 29 cases of the tibial plateau fractures who had been treated with operative treatment and followed up for more than 1 year from January 1991 to December 1997. The analysis of clinical results was performed dividing into age, cause of injury, fracture type of Schatzker classification, associated soft tissue injury and method of operative treatment. Results: According to Schatzker classification, 2 cases(6.9%) were type I, 11 cases(37.9%) were type II, 1 case(3.5%) was type III, 5 cases(17.2%) were type IV, 4 cases(13.8%) were type V, and 6 cases(20.7%) were type VI. In all cases, bony unions were obtained. According to Blokker evaluation, 23 cases(79.3%) of 29 cases were acceptable. Conclusion: We could expect good clinical results if early knee joint mobilization following minimal invasive open reduction and internal fixation could be obtained. Bad clinical results were related with young age group under 30, more than Schatzker classification type IV of high energy trauma and associated injury of anterior cruciated ligment or meniscus.

  • PDF

P Wave Dispersion as a Predictor of Idiopathic Paroxysmal Atrial Fibrillation (특발성 발작성 심방세동 환자에서 P파 간격분산의 의의)

  • Hong, Gue-Ru;Kim, Woong;Park, Jong-Seon;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.267-276
    • /
    • 2001
  • Background: P wave dispersion(PWD) is defined as the difference between the maximum and minimal P wave duration in any of the 12 leads of the surface ECG. The prolongation of atrial conduction time and the inhomogeneous propagation of sinus impulse are known electrophysiologic features in patients with paroxysmal atrial fibrillation(PAF). The purpose of this study was to determine the role of P wave dispersion for the prediction of PAF and to evaluate the effectiveness of prophylactic antiarrhythmic therapy. Materials and Methods: The study population included 20 patients with a history of idiopathic PAF and 20 age and sex matched healthy control subjects. We measured the maximum P wave duration(P maximum) and P wave dispersion from 12 lead ECG. Results: P maximum and P dispersion in idiopathic PAF were significantly higher than normal control group($97.2{\pm}12$, $48.5{\pm}9$ msec vs, $76.5{\pm}11$, $21{\pm}8$ msec, respectively p<0.001, <0.001). After 12-month follow up period P maximum and P dispersion were significantly reduced than those of initial state($77.2{\pm}13$, $26.4{\pm}9$ msec vs. $97.2{\pm}12$, $48.5{\pm}9$ msec, respectively p<0.001,<0.001). Conclusion: P dispersion and P maximum were significantly different between patients with idiopathic PAF and healthy control group. Those are easily accessible, non-invasive simple electrocadiographic markers that could be used for the prediction and prognostic factors of idiopathic PAF.

  • PDF

The Endocrine Changes and Alteration of the Ovarian Response to Clomiphen Citrate after Laparoscopic Laser Vaporization in Patients with Polycystic Ovary Syndrome (다낭성 난포 증후군 환자에서 복강경적 Laser Vaporization 후 내분비적 변화 및 클로미펜에 대한 난소 반응성의 변화)

  • Lee, Sang-Joon;Kim, Jin-Young;Park, Ki-Hyun;Choi, Kyu-Hong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.3
    • /
    • pp.483-490
    • /
    • 1999
  • Objectives: Polycystic ovary syndrome (PCOS) has the feature of excessive LH, hyperandrogenism and disturbance of folliculogenesis. Also, insulin, IGF-I and IGFBP-l are involved in the pathogenesis of PCOS. Various surgical and medical therapies have been used and the action mechanisms are related to the endocrine effect. Laparoscopic ovarian electrocautery or laser vaporization is effective in the restoration of ovulation and normal menstrual cycle with minimal invasive procedure especially in the patients resistant to medical therapy. Clomiphen citrate (CC) is used for the ovulation induction in pcas and the resistance is known to be related to insulin, IGF-I, IGFBP-l levels. This study was performed to evaluate the effect of the laparoscopic laser vaporization on the levels of LH, FSH, testosterone, IGF-I and IGFBP-l and on the ovarian response to clomiphen citrate in patients with CC-resistant PCOS. Materials and Methods: The fasting basal serum LH, FSH, testosterone, IGF-I and IGFBP-l level were measured in 10 PCOS patients with CC-resistance and 7 normal controls with regular menstrual cycle. In PCOS, after laparoscopic $CO_2$ laser vaporization, endocrine levels were measured in 1 week interval for 4 weeks and then compared with preoperative levels. Results: In PCOS group, mean serum LH/FSH ratio, testosterone, IGF-I levels were higher and IGFBP-l level was lower than control. LH/FSH ratio decreased from $2.51{\pm}0.67$ to $1.7{\pm}0.6$ (p<0.05) in 2 weeks, to $0.56{\pm}0.2$ (p<0.01) in 3 weeks and to $1.41{\pm}0.3$ (p<0.01) in 4 weeks after operation. Testosterone level decreased from $1.51{\pm}0.82ng/ml$ to $0.65{\pm}0.34ng/ml$ (p<0.05) in 2 weeks, to $0.56{\pm}0.67ng/ml $(p<0.01) in 3 weeks after operation. IGF-I level also decreased from $436{\pm}47.5{\mu}g/l$ to $187{\pm}38{\mu}g/l$ (p<0.0l) in 1 week, to $167{\pm}42{\mu}g/l$ (p<0.01) in 2 weeks, $179{\pm}55{\mu}g/l$ (p<0.01) in 3 weeks and to $120{\pm}43{\mu}g/l$ (p<0.01) in 4 weeks after operation. IGFBP-l level showed no significant change. In 8 of 10 PCOS patients, ovulation was induced with low dose clomiphen citrate. Conclusion: Laparoscopic $CO_2$ laser vaporization restores normal menstrual cycle and ovulation through endocrine effect of decreasing LH/FSH ratio, testosterone and IGF-I level and increases the response to CC. Therefore it is useful for restoration of normal menstruation and induction of ovulation in CC resistant PCOS patients.

  • PDF

RETROSPECTIVE STUDY OF SHORT ROUGH SURFACE IMPLANTS (짧은 길이의 거친 표면 임프란트에 대한 후향적 연구)

  • Kong, Jun-Ha;Lee, Baek-Soo;Kim, Yeo-Gab;Kwon, Yong-Dae;Yoon, Byung-Wook;Choi, Byung-Joon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.41-45
    • /
    • 2009
  • Background: Reduced bone height is one of the major problems faced in restoring tooth loss with implants. By the use of short implants, it is possible to reduce complicated and invasive treatment such as bone graft, allowing more simple surgery. But short implants are generally considered to have lower success rates than that of standard implants. Purpose: To assess the results of short Straumann implants by a retrospective study of short Straumann implants with TPS(titanium plasma-sprayed) and SLA(sandblasted, large grit, acid etched) surfaces. Materials and methods: 173 implants in 106 patients who received short Straumann implant surgery(${\le}8\;mm$) in the department of oral and maxillofacial surgery, Kyunghee Dental Hospital, from February 1996 to October 2006 were selected and studied. All of the implants were followed up after prosthetic rehabilitation. The average follow-up period was 34 months with 119 months as the longest follow up period. The average follow-up period after prosthetic rehabilitation was 31 months. 64 females(60.4%) and 42 males(39.6%) participated in the research with the age range of 19 to 85(mean age 47). 20 patients(18.9%) were under 40, 85 patients(80.2%) were over 40 and under 70, and only one patient(0.9%) was over 70 years old. Results: 27 implants(15.6%) had TPS surface while 146 implants(84.4%) had SLA surface. 9 implants(5.2%) were 3.3, 108 implans(62.4%) were 4.1mm and 56 implants(32.4%) were 4.8mm in diameter. 167 implants(96.5%) were 8mm and 6 implants(3.5%) were 6mm in length. There were 24 implants(13.9%) on the maxillas and 149 implants(68.8%) on the mandibles. 119 implants(68.8%) were rehabilitated with FPD(fixed partial denture), 47 implants(27.2%) with single crowns and 4 implants(2.3%) with overdentures. Among the fixed partial dentures, 30 of them were splinted with short implants only. After over an year of follow-up period, 139 implants(96.5%) out of 144 implants showed marginal bone loss of less than 1mm. 3 out of 173 implants failed showing 98.27% survival rate. Conclusions: The use of short Straumann implants(${\le}8mm$) can be a simple and reliable treatment method in minimal residual bone height.

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.3
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

Full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to worn dentition (전반적인 치아의 마모로 인한 수직고경 감소와 과피개교합을 갖는 환자의 전악 수복 증례)

  • Nam, Ki-Hun;Park, Pil-Kou;Kim, Hee-Kyung;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • Gradual occlusal attrition is a normal process of aging. However, severe attrition causes pathogenic pulp, occlusal disharmony, functional disorder and esthetic problems. Alteration of vertical dimension should be considered for space regaining for tooth restoration, esthetic improvement or correction of occlusal relationship. Vertical dimension should be determined within the range of minimal invasive process satisfying patient's esthetic requirements and operator's functional goal. And patient's adaptation to newly determined vertical dimension should be assessed simultaneously. Deep overbite is not a simple problem of overbite, instead it is an usually complicated problem with anterior-posterior occlusal relationship. Considering these facts, appropriate restoration of edentulous part as well as improvement of anterior-posterior relationship should be performed to solve this fundamental problems. In this study, a 67 year-old male patient with many worn teeth and loss of posterior teeth was treated with removable partial denture at edentulous mandibular area to increase vertical dimension and fixed prostheses at dentulous maxillary and mandibular area. With these treatments, we attained a satisfactory result in functional and esthetic aspects as a report case.

Clinical evaluation of implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles (Locator attachment를 이용한 하악 임플란트 유지형 피개의치의 임상적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.283-290
    • /
    • 2011
  • Purpose: This study compared the marginal bone loss around dental implant that were placed in the canine areas of the mandibles and finded the survival rate of implants, marginal bone loss around implants and prosthetic complications in 10 patients treated with overdentures retained with Locator attachments. Materials and methods: Ten patients who had received implant retained overdentures in the mandibules using two implants and Locator attachments at Daegu Catholic University Medical Center from 2004 to 2010 were included in this study. Evaluations of the survival rate of implants, marginal bone loss and prosthetic complications were performed. Results: Implants placed in this study showed a 100% survival rate and the average annual bone loss was 1.03 mm ${\pm}$ 0.20 mm in the first year. The patients have verbally indicated that they are comfortable and that their overdentures function well. But, implant retained overdentures had various prosthetic complications such as male change, relining, rebasing and denture fracture. Conclusion: Implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

Esthetic considerations for anterior implant-supported prostheses: focus on surgical and prosthetic treatment (전치부 임플란트의 연조직 심미성을 달성하기 위한 외과적, 보철적 고려사항)

  • Park, Yeon-Hee;Ahn, Seung-Geun;Kim, Kyoung-A;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.186-198
    • /
    • 2021
  • As the increased certainty of osseointegration, new parameters are now being used to assess implant success. Accordingly, patients' and clinicians' high demands and expectation for esthetics have expanded and implant-supported restorations show better esthetic outcomes. The pre-implant treatment planning process, the implant surgical steps and the post-surgery prosthetic process can affect all esthetic outcomes. Prevention of esthetic implant failures can be achieved by appropriate treatment at each stage, considering the 3 factors of alveolar bone, soft tissue, and implants. It is necessary to achieve the esthetic implant prostheses followings: minimal invasive surgery, bone augmentation, ideal 3-dimensional implant position, peri-implant soft tissue management, and provisional restorations to optimize peri-implant soft tissue architecture.