• Title/Summary/Keyword: Miniaturized

Search Result 678, Processing Time 0.031 seconds

One-component Room Temperature Vulcanizing-Type Silicone Rubber-Based Solid-State Carbonate Ion Selective Electrode (단일 조성 실온 경화형 실리콘러버를 지지체로 사용한 고체상 탄산이온선택성 전극의 개발)

  • Kim, Mi-Kyoung;Yoon, In-Jun;Cho, Sung-Ho;Shin, Hye-Ra;Han, Jong-Ho;Ha, Jeong-Han;Nam, Hak-Hyun;Cha, Geun-Sig
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.3
    • /
    • pp.266-272
    • /
    • 2004
  • We developed a miniaturized solid-state carbonate ion-selective electrode (carbonate ISE) based on one-component room temperature vulcanizing type silicone rubber 730 (730 RTV) without adding plasticizer to the matrix. The optimized carbonate ion selective membrane is prepared with 85.8 wt% of 730 RTV, 11.1 wt% of trifluoroacetyl-p-decylbenzene (TFADB), and 3.1 wt% of tridodecyl-methylammonium chloride (TDMACl). This carbonate ISE exhibited excellent potentiometric properties (i.e., slope: 26.3 mV/dec; selectivity: $logKT^{pot}_{CO_{2},Cl^-}$= -4.00 and $logKT^{pot}_{TCO_{2},Sal^-}$=1.69); and detection limit for $TCO_2:\;4.0{\times}10^{-4}M$). In addition, the early potentiometric properties of the solid-state sensor with optimized membrane composition were not deteriorated for more than 60 days.

Development and Verification of Modular 3U Cubesat Standard Platform (3U 큐브위성 표준 플랫폼의 개발)

  • Song, Sua;Lee, Soo-Yeon;Kim, Hongrae;Chang, Young-Keun
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.5
    • /
    • pp.65-75
    • /
    • 2017
  • This study proposes development of 3U CubeSat standard platform whose function and performance are verified via KAUSAT-5 development. 3U CubeSat platform specification was selected for the design of 3U Cubesat standard platform by examining existing CubeSat and state-of-art technology, and consequently a universally usable 3U CubeSat platform was designed. Standard platform was manufactured in 1.5U size and developed with a modular concept to be able to add and expand payloads and ADCS actuators for meeting the user's needs. In addition, in case of the power system, the solar panel, the battery, and the deployment mechanism are designed to be configured by the user. In the mechanical system design of a standard platform, subsystem and micro equipment functions/performance could be integrated and miniaturized on micro-sized PCBs and maximized electrical capability to accommodate multiple payloads. In the development of the 3U CubeSat, the satellite platform adopts the developed standard platform, which can reduce the cost and schedule for the whole satellite development by reducing the additional function verification.

Correlation between Skin Translucency and Scattering Reflection using Miniaturized New Optical Device (피부 투명감 측정 기기의 소형화 및 피부의 확산 반사광과 투명감 사이의 연구)

  • Lee, Myeong-Ryeol;Jeong, Choon-Bok;Junng, Yu-Chul;Kim, Han-Kon;Nam, Gae-Won
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.37 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • Skin darkness is the source of trouble to many women. Skin darkness is the state that while skin redness and brightness are reduced, skin yellowness is increased. Skin translucency which is measured by skin color, especially brightness is an another expression of skin darkness. Skin brightness is usually expressed by L value of $L^{*} \;a^{*}\; b^{*}$ (CIELAB color space system). However, it is hard to find the relationship between L value and perceptive efficacy such as translucency because the L value is just a factor of evaluation of skin darkness. The skin with high translucency has high scattering reflective light value than low value. In this study, we measured the skin translucency of 20 ~ 30 ages men and women face by both our designed previous device which use polarized light to detect surface and scatter reflective light independently and $Lumiscan^{TM}$ which is improved designed to confirm our new device working ability by calculation of relationship between trnaslucency and scattering reflective light value. The result of this study indicate that there is a high correlation (R = 0.732, p < 0.01) between translucency and scattering reflective light value, and suggest that $Lumiscan^{TM}$ is portable and easy measuring device more that previous device.

Step-down Piezoelectric Transformer Using PZT PMNS Ceramics

  • Lim Kee-Joe;Park Seong-Hee;Kwon Oh-Deok;Kang Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.102-110
    • /
    • 2005
  • Piezoelectric transformers(PT) are expected to be small, thin and highly efficient, and which are attractive as a transformer with high power density for step down voltage. For these reasons, we have attempted to develop a step-down PT for the miniaturized adaptor. We propose a PT, operating in thickness extensional vibration mode for step-down voltage. This PT consists of a multi-layered construction in the thickness direction. In order to develop the step-down PT of 10 W class and turn ratio of 0.1 with high efficiency and miniaturization, the piezoelectric ceramics and PT designs are estimated with a variety of characteristics. The basic composition of piezoelectric ceramics consists of ternary yPb(Zr$_{x}$Ti$_{1-x}$)O$_{3}$-(1-y)Pb(Mn$_{1/3}$Nb1$_{1/3}$Sb$_{1/3}$)O$_{3}$. In the piezoelectric characteristics evaluations, at y=0.95 and x=0.505, the electromechanical coupling factor(K$_{p}$) is 58$\%$, piezoelectric strain constant(d$_{33}$) is 270 pC/N, mechanical quality factor(Qr$_{m}$) is 1520, permittivity($\varepsilon$/ 0) is 1500, and Curie temperature is 350 $^{\circ}C$. At y = 0.90 and x = 0.500, kp is 56$\%$, d33 is 250 pC/N, Q$_{m}$ is 1820, $\varepsilon$$_{33}$$^{T}$/$\varepsilon$$_{0}$ is 1120, and Curie temperature is 290 $^{\circ}C$. It shows the excellent properties at morphotropic phase boundary regions. PZT-PMNS ceramic may be available for high power piezoelectric devices such as PTs. The design of step-down PTs for adaptor proposes a multi-layer structure to overcome some structural defects of conventional PTs. In order to design PTs and analyze their performances, the finite element analysis and equivalent circuit analysis method are applied. The maximum peak of gain G as a first mode for thickness extensional vibration occurs near 0.85 MHz at load resistance of 10 .The peak of second mode at 1.7 MHz is 0.12 and the efficiency is 92$\%$.

Evaluation of Active Layer Depth using Dynamic Cone Penetrometer (동적 콘 관입기를 이용한 활동층 심도평가)

  • Hong, Won-Taek;Kang, Seonghun;Park, Keunbo;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.1
    • /
    • pp.49-54
    • /
    • 2016
  • An active layer distributed on surface of an extreme cold region causes a frost heave by repeating the freezing and thawing according to the seasonal temperature change. Since the height of frost heave is greatly affected by the thickness of active layer, an accurate evaluation of the thickness of active layer is necessary for the safe design and construction of the infrastructure in the extreme cold region. In this study, dynamic cone penetrometer, which is miniaturized in-situ penetration device, is applied for the evaluation of active layer depth distribution. As the application tests, two dynamic cone penetration tests were conducted on the study sites located in Solomon and Alaska. In addition, ground temperature variations were obtained. As the results of the application tests, the depth of interface between the active layer and the permafrost was evaluated from the difference in dynamic cone penetration indexes of the active layer and the permafrost, and a layer was detected around the interface considered as an ice lens layer. Also, the interface depths between the above zero and the below zero temperature determined from the ground temperature variations correspond with the interface depths evaluated from the dynamic cone penetration tests. This study demonstrates that the dynamic cone penetrometer may be a useful tool for the evaluation of the active layer in the extreme cold region.

THE EFFECT OF THE SUPERSATURATED SOLUTIONS CONTAINING HIGH CONCENTRATIONS OF FLUORIDE ON SEEDED CRYSTAL GROWTH (고농도의 불소를 포함하는 과포화용액이 apatitic crystal growth에 미치는 영향)

  • Kwun, Jung-Won;Kum, Kee-Yeon;Lee, Seung-Jong;Jung, Il-Young;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.330-336
    • /
    • 1999
  • In biological systems, the mineral that forms hard tissue is of an apatitic nature, and hydroxyapatite($Ca_5OH(PO_4)_3$: HA) is generally considered as the prototype for such a mineral. Thus, the precipitation of HA, having biological implications, has been the subject of several investigations. Crystal growth studies using HA seeds in supersaturated solutions have enhanced our understanding of the process and mechanism involved in seeded crystal growth. From these studies, it has become apparent that the precipitation rate of HA onto the seed crystals depends on the various conditions, especially on the additives. The relation between the supersaturated solution containing fluoride and the process of HA crystal growth enhances the understanding of mechanism of HA crystal growth. Until recently, the studies have been on the crystal growth of enamel minerals and synthetic HA seeds in the supersaturated solution containing 1~2 ppm fluoride. The purpose of the present investigation is to study the effect that fluoride of high concentration has on the crystal growth kinetics of HA. In order to produce the composition found in the secretory enamel fluid, experimental solutions of 1mM Ca, 3mM P, and 100mM Tris as background electrolyte were used. Then this experimental solutions were added to 0, 2, 4, 6, 8, 10 ppm fluoride. The effect of fluoride at high concentrations on the precipitation was examined in a bench-top crystal growth model adopting a miniaturized reaction column. Chemical analysis was employed for characterization of working solutions before and after the experimentation. Remarkable findings were : 1) the amount of crystal growth was gradually accelerated as the fluoride concentration increased until 6 ppm, but decreased in 8 and 10 ppm fluoride; 2) the amount of fluoride ion consumed in crystal formation was constant despite the increase in fluoride concentration.

  • PDF

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Miniaturized DBS Downconverter MMIC Showing a Low Noise and Low Power Dissipation Characteristic (저잡음ㆍ저소비전력 특성을 가지는 위성방송 수신용 초소형 다운컨버터 MMIC)

  • Yun, Young
    • Journal of Navigation and Port Research
    • /
    • v.27 no.4
    • /
    • pp.443-447
    • /
    • 2003
  • In this work. using 0.2 GaAs modulation doped FET(MODFET), a high performance DBS downconverter MMIC was developed for direct broadcasting satellite (DBS) application. Without LNA, the downconverter MMIC showed a very low noise of 4.8 dB, which is lower by 3 dB than conventional ones. A low LO power of -10 dBm was required for the normal DBS operation of the downconverter MMIC. which reduced the power consumption via a removal of LO amplifier on MMIC. It required only a low power consumption of 175 mW, which is lower than 70 percent of conventional ones. The LO leakage power at IF output was suppressed to a lower level than 30 dBm, which removes a bulky LO rejection filter on a board. The fabricated chip, which include a mixer, If amplifiers. LO rejection filter, and active balun, exhibited a small size of $0.84{\times}0.9\textrm{mm}^2$.

Pin Distribute Method of Twist Cable at Military Unmanned Vehicle Wiring Unit Connector (군용 무인 이동체 배선장치 커넥터에서 트위스트 케이블 핀 배치 최적화 방안)

  • Eun, Hee-hyun;Roh, Dong-gyu;Kwak, Gyu-min;Kim, Jae-seung;Lee, Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.4
    • /
    • pp.245-250
    • /
    • 2020
  • Currently, unmanned military vehicles under development in Korea have more devices to carry out various missions, and interface cables between them are also increasing. In addition, due to a small space problem inside the unmanned vehicle, devices are required to be miniaturized and integrated. For two reasons, connectors also need to be selected, which makes them vulnerable to noise due to the closer distance between the pins. In this paper, we analyzed how much the magnetic field produced by noise at the connector pin where cable twist is released affects the surrounding pin and presented the guide for optimal pin placement. First, the effect of magnetic field is greater than the crosstalk between pin and pin. Second, the magnetic field on both sides between + and - is strong when approaching one step with noise source. Third, the magnetic field strength is improved when setting the ground pin as the ground pin between the noise and the original signal when approaching the A noise source and the two steps. Fourth, in the case of a differential mode communication, the optimal placement area of the sensitive signal was presented according to positions Tx± and Rx±.

Implementation and Evaluation of ECG Authentication System Using Wearable Device (웨어러블 디바이스를 활용한 ECG 인증 시스템 구현 및 평가)

  • Heo, Jae-Wook;Jin, Sun-Woo;Jun, Moon-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.1-6
    • /
    • 2019
  • As mobile technologies such as Internet of Things (IoT)-based smart homes and financial technologies (FinTech) are developed, authentication by smart devices is used everywhere. As a result, presence-based biometric authentication using smart devices has become a new mainstream in knowledge-based authentication methods like the existing passwords. The electrocardiogram (ECG) is less prone to forgery, and high-level personal identification is its unique feature from among various biometric authentication methods, such as the pulse, fingerprints, the face, and the iris. Biometric authentication using an ECG is receiving a great deal of attention due to its uses in healthcare and FinTech. In this study, we implemented an ECG authentication system that allows users to easily measure and authenticate their ECG waveforms using a miniaturized wearable device, rather than a large and expensive measurement device. The implemented ECG authentication system identifies ECG features through P-Q-R-S-T feature point identification, and was user-certified under the proposed authentication protocols. Finally, assessment of measurements in a majority of adult males showed a relatively low false acceptance rate of 1.73%, and a low false rejection rate of 4.14%, in a stable normal state. In a high-activity state, the false acceptance rate was 13.72%, and the false rejection rate was 21.68%. In a high-heart rate state, the false acceptance rate was 10.48%, and the false rejection rate was 11.21%.