• Title/Summary/Keyword: Miniature

Search Result 813, Processing Time 0.029 seconds

Development of a Miniature Aerosol Separator for a Black Carbon Measuring Instrument (블랙카본 측정기용 초소형 사이클론 집진기 개발)

  • An, Ik-Hyun;Lim, Jun-Hyung;Lee, Hyo-Young;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.42-48
    • /
    • 2020
  • Given the increasing interest in air pollution, several technologies to measure black carbon (BC) aerosol particles have been developed. As most BC aerosol particles are smaller than 1 ㎛, it is necessary to pre-separate the particles by size before a BC measuring instrument samples the aerosol particles. In this study, a miniature cyclone separator for portable BC measuring instruments was developed. A numerical approach was used to design the miniature cyclone separator with operating flow rates of 50, 100, or 150 mLPM, and then a prototype cyclone separator was manufactured for experimental validation. The numerical results of the cut-off size and pressure drop of the miniature cyclone separator agreed well with the experimental data. The cut-off sizes of the miniature cyclone separator were determined to be 2.9, 0.94, and 0.63 ㎛ for operating flow rates of 50, 100, and 150 mLPM, respectively. Thus, the miniature cyclone separator is suitable for use as a sampling inlet for the portable black carbon measuring instrument to sample BC aerosol or PM2.5 aerosol.

Design of the miniature Joule-Thomson refrigerator as a cryoprobe (저온 수술 프로브용 소형 Joule-Thomson 냉동기의 설계)

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon;In, Se-Hwan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.86-90
    • /
    • 2007
  • The cryoprobe used in cryosurgery should be fabricated in milimeter-order size for its practical usage. In general a miniature J-T(Joule-Thomson) refrigerator is applied to a cryoprobe. In case of the miniature J-T refrigerator, the mass flow rate of working fluid is small due to considerable friction in a minute flow path. For that reason, the miniature J-T refrigerator has a limited cooling power. To obtain the large cooling power from the J-T refrigerator, the refrigerator should have large mass flow rate and effective J-T temperature drop. These quantities are closely related to the geometry of the heat exchanger and the expansion nozzle in a cryoprobe, and are contradictory. The large mass flow rate leads to the small J-T temperature drop and vice versa in the miniature J-T refrigerator. Therefore, the optimal design of a cryoprobe to achieve maximum cooling power at fixed tube size and fixed operating temperature is required. This paper presents the design procedure of such case.

Changes of Frozen-Thawed Semen Characteristics in Miniature Pig and Duroc (Miniature Pig와 Duroc 종간의 동결-융해 후 정액 성상 비교)

  • Lee, Y.S.;Choi, W.C.;Lee, S.H.;Cheong, H.T.;Lee, S.Y.;Yang, B.K.;Park, C.K.
    • Journal of Embryo Transfer
    • /
    • v.21 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • The purpose of this study was undertaken to compare ability of frozen-thawed sperm characteristics between two strains (miniature pig and Duroc). The semen was collected by gloved-hand method into a pre-warmed ($37^{\circ}C$) thermos bottle. The semen was diluted with same volume extender and added to LEY solution for freezing. The diluted semen was placed in 0.5 ml straws, and freezing was initiated by exposing the straws to liquid nitrogen ($LN_2$) vapours for 10 min before placing them into $LN_2$ for cryopreservation. The frozen-semen straw were thawed at 20, 37 and $50^{\circ}C$ for 1 min, 45 sec and 10 sec within water-bath. The semen sample were evaluated at 0, 3, 6, 9, and 12 h after incubation at $37^{\circ}C$ for analysis of sperm ability. Abnormality of spermatozoa in miniature pig was significantly (p<0.05) higher than that in Duroc at 0, 9 and 12 h of post-thawing incubation after frozen-thawing. The percentage of F-patterned spermatozoa in miniature pig was significantly (p<0.05) lower, while the percentage of AR (acrosome reacted spermatozoa) pattern was higher in the miniature than in the Duroc. On the other hand, there was no significant difference in the viability of spermatozoa thawed at different temperature ($20^{\circ}C\;and\;37^{\circ}C$) between two species, but the viability in miniature pig was higher (p<0.05) than in Duroc when sperm was thawed at $50^{\circ}C$. In conclusion, this study suggest that suitable freezing method for miniature pig semen is required for increasing post-thawing viability and fertilization capacity.

Analysis of Sperm Ability in Specific Pathogen Free Miniature pig for Production of Bio-Organ

  • Kim T. S.;Cao Y.;Cheong H. T.;Yang B. K.;Park C. K.
    • Reproductive and Developmental Biology
    • /
    • v.29 no.3
    • /
    • pp.149-154
    • /
    • 2005
  • The purpose of this study was the analysis of sperm ability in Specific Pathogen Free (SPE) miniature pig for production of bio-organ. The collected semen was diluted with extender and stored at $17^{\circ}C$t for up to 7 days. The semen samples were evaluated at 0, 1, 3, 5, and 7 days of storage for analysis of sperm ability. Sperm ability was evaluated by examining viability, progressive motility, sperm abnormality and intensity of the sperm membrane. Also, the semen was processed according to the convenient freezing method, and frozen-thawed sperm was evaluated by examining viability, capacitation and acrosome reaction using chlortetracycline (CTC) staining. Motility of spermatozoa of SPF miniature pig was significantly (P<0.05) lower on 3 days or later compared to the Duroc, Yorkshire and Landrace in domestic boar. The percentage of abnormal spermatozoa of Landrace were significantly (P<0.05) higher than in SPF miniature pig, Duroc and Yorkshire that had a similar percentage on 5 or 7 days of sperm storage. The percentage of spermatozoa with coiled tail decreased during the storage period but there were no significant difference. On the other hand, viability of frozen-thawed spermatozoa had a significantly (P<0.05) lower in SPF miniature pig than in other domestic boars. CTC patterns had no significant difference, but SPF miniature pig had higher percentage of capacitated spermatozoa and lower percentage of acrosome-reacted it than domestic boars. Therefore, this study suggest that it is necessary to develop the suitable extender and freezing methods methods for the high viable rate and fertilizing ability in vitro.

Relative Analysis between Fertility and Protein Changes in Semen of Different Species in Pigs (돼지 품종간 정액 내에서 수정 능력과 단백질 변화와의 관계 분석)

  • Lee, Yeon-Ju;Lee, Sang-Hee;Kim, Yu-Jin;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.38 no.1
    • /
    • pp.53-62
    • /
    • 2014
  • The objective of this study was to investigate the relationship between fertility and protein pattern change using in vitro fertilization, analysis of sperm characteristics and two-dimensional gel electrophoresis in different pig types. In results, the viability and mitochondria integrity of sperm were higher significantly (p<0.05) but the portions of acrosome reaction was lower significantly (p<0.05) in Duroc and $F_1$ (potbellied ${\times}$ PWG miniature pig) than PWG miniature. On in vitro fertilization to investigate fertility, the fertility of $F_1$ semen war higher significantly (p<0.05) than in Duroc and PWG miniature pig. On the other hand, protein patterns showed similar function among the different boar semen. Especially, the heat shock 70 kDa 1-like and G patch domain-containing protein 4 were significantly (p<0.05) higher expressed in $F_1$ than in Duroc and PWG miniature pig. The proteins associated with mitochondria in Duroc were significantly (p<0.05) higher expressed than in $F_1$ and PWG miniature pig. The developmental rates to blastocyst stage of oocytes fertilized with sperm of $F_1$ pig were significantly (p<0.05) higher than in PWG miniature pig. However, phosphoglycerate kinase 2 and zinc finger protein 431 were significantly (p<0.05) higher expressed in PWG miniature pig than in $F_1$ and Duroc pigs. In conclusion, the results of the present study indicate that different proteins were expressed in different pig types, and were associated with a sperm functions and embryo development.

Effects of L-Carnitine and Nicotinic Acid on Sperm Characteristics in Miniature Pigs

  • Lee, Yeon-Ju;Lee, Sang-Hee;Kim, Yu-Jin;Hwangbo, Yong;Lee, Seunghyung;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.40 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • This study investigated the effects of L-carnitine (LC) and nicotinic acid (NA) on sperm viability during liquid storage at $18^{\circ}C$ in miniature pigs. $10{\mu}M$ LC and 30 mM NA, combined LC and NA (LN) were treated in fresh semen for 3, 7, and 10 days. In results, sperm survival increased in NA- and LN-treated semen on 7 and 10 days (p<0.05), mitochondrial integrity of live sperm increased in LN-treated semen on 7 days (p<0.05), but not NA-treated semen. In addition, we examined the acrosome reaction of sperm in miniature pigs. LC and NA did not influence on acrosome reaction of boar sperm. In conclusion, LC and NA effectively maintained the viability and quality of sperm during long-term storage in miniature pigs, suggesting that the combined LN may be useful for improving the semen extender for long-term liquid storage in pigs.

Development of a Stereoscopic Miniature PIV(MPIV) System (Stereoscopic Miniature PIV (MPIV) 시스템의 개발)

  • Kim S.H.;Chete1at O.;Kim K.C.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.517-520
    • /
    • 2002
  • Stereoscopic particle image velocimetry is a measurement technique to acquire of three dimensional velocity field by two cameras. With a laser sheet illumination, the third velocity component can be deduced by out-of-plane velocity components using a stereoscopic matching method. Industrial fluid flows are almost three dimensional turbulent flows, so it is necessary to use the stereoscopic PIV measurement method. However the existing stereoscopic PIV system seems hard to use since it is very expensive and complex. In this study we have developed a Stereoscopic Miniature PIV(MPIV) system based on the concept of the Miniature PIV system which we have already developed. In this paper, we address the design and some first experimental results of the stereoscopic PIV system. The Stereoscopic MPIV system features relatively modest performances, but is considerably smaller, cheaper and easy to handle. The proposed Stereoscopic MPIV system uses two one-chip-only CMOS cameras with digital output. Only two other chips are needed, one for a buffer memory and one for an interfacing logic that controls the system. Images are transferred to a personal computer (PC) via its standard parallel port. No extra hardware is required (in particular, no frame grabber board is needed).

  • PDF

Sex Determination and Parentage Testing In Miniature Horses (Miniature 말의 성(sex) 결정과 친자감정)

  • Cho Gil-jae;Cho Byung-wook
    • Journal of Life Science
    • /
    • v.15 no.1 s.68
    • /
    • pp.45-48
    • /
    • 2005
  • The aim of this study was to construct a correct pedigree of miniature horses (MH). The sex of MH was detected by PCR amplification of the sex determining region of the Y chromosome gene (SRY) prior to parentage testing. Ten random MH samples for parentage testing were genotyped by using 16 micro satellite markers. Since the SRY band (430 bp) was detected in horses No.1, 2, 6, 7, 8, 9, 10, these are male. However, the DNA segment was not identified in horses No.3, 4, and 5, which therefore are female. After genotyping, parentage testing was performed according to Mendelian fashion and International Society for Animal Genetics (ISAG) guideline. Of the 10 MH, 3 were qualified by the compatibility of 16 markers according to Mendelian fashion in the present DNA typing for parentage verification. These results can provide basic information for developing parentage verification and an individual identification system in MH.

Deformation Characteristics of Miniature Tensile Specimens of a SA 508 C1.3 Reactor Pressure Vessel Steel

  • Byun, Thak-Sang;Chi, Se-Hwan;Hong, Jun-Hwa;Jeong, Ill-Seok;Hong, Sung-Yull
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.182-187
    • /
    • 1996
  • Deformation characteristics of miniature plate tensile specimens have been studied to develop the thickness requirement and a correlation to estimate the mechanical properties of bulk material from miniature specimen data. The material used was a SA 508 C1.3 reactor pressure vessel steel and the thicknesses of miniature tensile specimens varied from ().12 m to 2 mm. The effects of thickness on the tensile deformation properties such as strength, ductility, and necking characteristics were analyzed. The yield and ultimate tensile strengths were independent of specimen thickness when the thickness was larger than about 0.2 mm. The uniform and total elongations decreased as the specimen thickness decreased. It was also observed that the uniform strain component in the width direction decreased with decrease in the specimen thickness, however, that in the thickness direction was rather constant in total thickness range studied. Based on this observation and a relationship between the necking angle and the ratio between strain components, a correlation between the uniform elongations of miniature specimen and standard specimen was derived. The uniform elongations calculated by this new correlation agreed well with the measured values.

  • PDF

A Study on the Application of High-Power GaN SSPA for Miniature Radar (GaN 고출력 증폭기의 초소형 레이다 적용에 관한 연구)

  • Lee, Sang_yeop;Yi, Jaewoong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.574-581
    • /
    • 2016
  • Trend on high-power GaN(Gallium Nitride) SSPA(Solid-State Power Amplifier) and its availability in miniature radar systems are presented. There are numerous studies on high-power GaN devices since they have some characteristics of high-breakdown voltage, high power density, and high-temperature stability. Recent scaled GaN technology makes it possible to apply it in SSPAs for W- and G-band applications, with increasing its maximum frequency. In addition, it leads to downsizing and power-efficiency improvement of SSPAs, which means that GaN SSPAs can be available in miniature radar systems. This study also shows radar performance and comparison in the case of using such SSPAs at three frequency bands of Ku, Ka, and W. Finally, we demonstrate prospects of scaled GaN SSPAs in future miniature radar systems.