• 제목/요약/키워드: Mineral oil

검색결과 531건 처리시간 0.029초

Effect of Refrigeration Oil on the Condensation Heat Transfer for R-22 and R-407C Refrigerations in Microfin Tube with a U-bend

  • Cho, Keum-Nam;Tae, Sang-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권2호
    • /
    • pp.85-93
    • /
    • 2001
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-22 and R-407C in a microfin tube with a U-bend. Mineral oil and POE oil were used for R-22 and R-407C respectively. Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to 400 $kg/m^2s$ and an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. The decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the 90$^{\circ}$position. the heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

마이크로핀관 곡관부내 대체 냉매의 응축 열전달에 미치는 냉동기유의 영향 (Effect of Refrigeration Oil on the Condensation Heat Transfer for Alternative Refrigerant in Microfin Tube with a U-bend)

  • 태상진;조금남
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.541-549
    • /
    • 2000
  • The present study experimentally investigated the effect of refrigeration oil on the condensation heat transfer for R-407C and R-22 in a microfin tube with a U-bend. POE oil ($74.1\;\textrm{mm}^2/s,\;40^{\circ}C$,) and mineral oil $62.5\;\textrm{mm}^2/s,\;40^{\circ}C$,) were used for R-407C and R-22 respectively Experimental parameters were an oil concentration from 0 to 5%, a mass flux from 100 to $400kg/m^{2}s sand an inlet quality from 0.5 to 0.9. The enhancement factors for both R-22 and R-407C refrigerants at the first straight section decreased continuously as the oil concentration increased. They decreased rapidly as the mass flux decreased and the inlet quality increased. The heat transfer coefficients in the U-bend showed the maximum at the $90^{\circ}$/TEX> position. The heat transfer coefficients at the second straight section within the dimensionless length of 48 were larger by a maximum of 33% than the average heat transfer coefficient at the first straight section.

  • PDF

오일함침 나일론 6의 합성 및 마찰특성 (Synthesis and Friction Properties of Oil-impregnated Nylon 6)

  • 정대원;강석춘
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.726-728
    • /
    • 1998
  • ${\varepsilon}$-caprolactam의 음이온 중합반응을 미네랄 오일의 존재하에서 수행하여 오일함침 나일론 6을 합성하였다. 8 phr 미만의 오일이 첨가되었을 때에는 중합반응속도 및 생성물의 분자량에 큰 변화가 없었다. 오일의 첨가에 의해서 생성물의 신율 및 충격강도는 향상되었으며, 표면경도와 인장강도는 저하되었다. 오일함량이 6 phr인 나일론에서 마찰계수는 최소값을 나타내었으며, 이때의 마찰계수값은 오일이 첨가되지 않은 나일론의 32%에 지나지 않았다.

  • PDF

식물성 오일의 혼합조건에 따른 윤활 특성 연구 (Study on Lubrication Characteristics of Vegetable Oil Based on Blending Condition)

  • 정희영;김현준
    • Tribology and Lubricants
    • /
    • 제36권6호
    • /
    • pp.342-349
    • /
    • 2020
  • The rapidly increasing threats to the environmental has increased the demand for biodegradable lubricants. Vegetable oils, such as olive, coconut, and sunflower oils, are readily obtainable and are not harmful, unlike synthetic and mineral oils. The tribological characteristics of these oils should be adequately examined for industrial applications. In this study, the lubrication characteristics of olive oil is investigated using a pin-on-disk-type tribometer under 500 gf of normal force, and the examination results are compared and analyzed with those of commercial synthetic lubricants for friction and wear. In addition, stearic acid, which is a type of saturated fatty acid, is mixed with olive oil as an additive to improve its lubrication characteristics. Olive oil with stearic acid additive is thus observed to exhibit the lowest friction coefficient for rotational speeds of 200 to 800 rpm. According to the wear analysis, a minimal amount of wear is observed when no additive is used. Hence, olive oil is able to effectively reduce friction and wear at relatively low speeds. These low friction and wear characteristics of olive oil are attributed to its compatibility with the substrate.

활선중 절연유 분석을 통한 유입변압기 건전성 평가 방법에 관한 연구 (A Study on the Health Evaluation Method of Oil-immersed Transformer through Analysis of Insulating Oil)

  • 신연진;임재용
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.1-8
    • /
    • 2023
  • The health state of the oil transformer is evaluated by the age of use and the state of internal defects. Mineral Oil, used as an insulator for oil transformers, creates specific gases and compounds through chemical reactions caused by heat, moisture, and partial discharge inside the transformer. It is possible to determine the aging and defect of the transformer through these gases and compounds. So, it is an important indicator to evaluate the health of a transformer. In this study, factors for assessing the health of transformers were hierarchically categorized, and key factors for each hierarchy were selected for design weighting. These weights were determined through surveys conducted with experts in the fields of transformer design, operation, and quality. For the health of a transformer, defect-related factors are approximately three times more important than factors related to aging. Additionally, defect-related factors showed a higher weighting for gases generated at high temperatures. Furthermore, Furan was determined to have a high weight, directly associated with insulating paper aging. Based on these findings, a health index was proposed, and a comparative analysis was conducted by categorizing 40 operational transformers into normal and comparison groups to evaluate and validate it.

사이클론 방식 압축기 유분리기의 나선 피치 설계 (DESIGN OF HELIX PITCH OF A CYCLONE TYPE OIL SEPARATOR FOR A COMPRESSOR)

  • 장성일;안준
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.8-13
    • /
    • 2014
  • A series of numerical simulation has been carried out to study performance of a cyclone type oil separator, which is designed for the compressor of a refrigeration system. Working fluid is R22, which is a typical refrigerant, and mineral oil droplet is supplied. Pitch of the helix is considered as design parameters to make a compact separator. Depending on the helix pitch, separation efficiency varies from 97.5 to 99%, while predicted pressure drop ranges from 5 to 6.5 kPa. Considering both of the pressure drop and separation efficiency, helix pitch of the separator has been designed as 50 mm.

초음파 오일 스러지 처리 시스템 개발을 위한 기초 연구 (A Basic Study on the Development of Oily Sludge Treatment System by Ultrasonic Waves)

  • 이은방
    • 해양환경안전학회지
    • /
    • 제6권1호
    • /
    • pp.57-67
    • /
    • 2000
  • All crude oil carries a little of water, sand, and mineral sediment molecules tightly bounded with hydrocarbons. The result is the gradual precipitation of these heavier elements into thick, granular petroleum by products known as crude oil sludge. The oily sludges in ship tanks and in storage facilities have to be treated efficiently in order to keep the security and the capacity of storage facilities, to protect a serious environmental pollution, and to retrieve lost resource. The oily sludge treatment system should be designed to satisfy requirements mentioned in safe work condition. As a basic study, in this paper, an oily sludge treatment system by ultrasonic waves was proposed. Then, the features of ultrasonic energy and recovery of sludge with ultrasonic waves are investigated by experiments. As results, we found that ultrasonic waves are a new energy to flow oil sludge environment-friendly in safe work condition. In addition, it was shown that ultrasonic energy is more efficient than thermal energy in treating oil sludge, and that the volume of wastes for disposal is reduced remarkably.

  • PDF

열 열화에 따른 변압기 절연물의 절연특성 분석 (Analysis of Insulation Characteristics for Transformer Insulating Materials According to Thermal Degradation)

  • 이민구;심재명;임경범;이대동
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1688-1693
    • /
    • 2016
  • In this study shall investigate the influence upon the electrical property of transformer oil due to the heat among accelerated heat degradation experiment for a constant hour in the typical insulation oils of mineral base oil, silicon base oil and vegetable oil. In addition, the electric insulation performance of insulation materials in transformer shall be evaluated through the electric property analysis according to the heat degradation of epoxy insulation material, which has been used for electric facilities such as a molded transformer.

Tribology 관점에서 생분해성 유압작동유 실적용 평가에 관한 연구 (Study on vehicle application of biodegradable hydraulic oils from the point of tribological evaluation technology)

  • 나병철;김진용;서준호
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.367-371
    • /
    • 2004
  • Bio-degradable hydraulic oil using polyolester base oil is formulated for the applications of heavy duty hydraulic machineries. It has proved quality and market price competitiveness by assessment of reliability test in vehicle manufacturer and specific vehicle related institute. Contribution of bio-degradable oil keep the working environment clean and increase export competitiveness in European market. Leakage or waste of mineral types of hydraulic oils in heavy duty machineries causes pollution of river, ocean, underground water. Drinkable-water pollution is serious problem in Europe. In some European countries, using bio-degradable hydraulic oils become an obligation in heavy duty machineries. New product of bio-degradable oils satisfy the European regulations(OECD 302B) and shows excellent performance in compare with European products.

  • PDF

식물성 절연유의 열 열화에 따른 전기적 특성 연구 (Analysis on the Electric Characteristics of Natural Ester after Accelerated Thermal Aging)

  • 심명섭;안정식;최순호;정중일;김남렬;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.81-81
    • /
    • 2010
  • This paper presents results of experimental investigations on natural ester regarding the breakdown strength. Aging of insulating material in a pole transformer has been studied by performing accelerated thermal aging test. Sealed aging test vessels containing copper, laminated core, Krapt paper and insulating oil(Natural oil and Mineral oil) were aged at $140^{\circ}C$ for 30days. Compared to the conventional transformer oil, electric property of the natural ester fluid is excellent.

  • PDF